Introduction
The rapid development of laser technology and laser-plasma acceleration techniques has provided high-quality electron bunches with vastly adjustable energies, leading to effective laser-based X-ray and γ-ray sources [1]. This provides extensive opportunities in the photonuclear field such as medical isotope production [2-4], nuclear waste transmutation [5-7], isomer generation [8], and photonuclear data measurements [9-12]. In these applications, electrons are accelerated by ultrafast laser pulses, typically through laser wakefield acceleration (LWFA) or direct laser acceleration (DLA), and bombarding a bremsstrahlung converter, leading to photon emission and subsequent photonuclear reactions with the target material. Since most responses are distributed within the giant dipole resonance (GDR) region, the laser-driven γ source must maximize photon production within this energy range.
Medical radioisotopes can generally be obtained in two ways: nuclear reactions in particle accelerators and the fission of highly enriched uranium in nuclear reactors, each of which has non-negligible shortcomings [13]. Cyclotrons are primarily employed to produce short-lived, neutron-deficient, β+-emitting radioisotopes. However, these radioisotopes must be used promptly after production owing to their short half-lives. Therefore, many medical centers must spend considerable amounts of money and space to maintain their own accelerators. By contrast, research reactors primarily manufacture long-lived β-- and γ-ray-emitting radioisotopes. They often need to be distributed before use. However, the vast amount of nuclear waste generated during the production and transport of highly radioactive materials over extended distances afterward can cause environmental contamination risks. Therefore, a new, compact, environmentally safe, and cost-effective technology for the production of radioisotopes is required.
Photonuclear reactions using laser-driven γ photons have long been considered as promising alternatives for isotope production [14, 15]. The rapid progress in laser manufacturing technology has made high-intensity and high-repetition-rate laser systems smaller and more cost-effective, allowing for the decentralized production of medical isotopes, thus mitigating issues arising during transportation [16]. Bremsstrahlung γ-ray reaction routes produce very little radioactive waste, making them environmentally safe. Moreover, the narrow focal spot of the laser confines the reaction to a small area, which significantly increases the specific activity of the isotope.
This study focused on the (γ, p) generation of two selected medical isotopes: 47Sc and 67Cu. Using the (γ, p) reaction to produce radioisotopes has an additional advantage because this process involves element transfer, making it possible to extract and enrich the target isotopes through chemical mechanisms that are more convenient and less expensive than physical centrifugal separation. 47Sc and 67Cu were both highlighted as promising theranostic radionuclides by the recent IAEA Coordinated Research Project (CRP) on "Therapeutic Radiopharmaceuticals Labelled with New Emerging Radionuclides (67Cu, 186Re, 47Sc)" (IAEA CRP no. F22053). However, their limited availability owing to a lack of widely established production methods remains a problem [17, 18]. 47Sc(T1/2 = 3.3 d) is an excellent theranostic radionuclide considering its 100% β- emitter nature, and the combination of 44Sc+47Sc is gaining increasing attention as an excellently matched pair of nuclides for positron emission tomography (PET) imaging and radionuclide therapy [17]. Owing to the location of 47Sc in the nuclide chart, the photonuclear reaction
Herein, we employ both experiments and simulations to explore the potential for producing the radioisotopes 47Sc and 67Cu via laser-induced (γ, p) reactions. Section 2 introduces the experimental setup and the obtained results. We cross-validated the experimental outcomes with our simulation results and optimized the target parameters to achieve the theoretical maximum yield under the experimental electron conditions in Sect. 3. In Sect. 4, further optimization of the electron acceleration mechanism indicated that the maximum yield is achievable with a typical 200 TW laser, similar to CLAPA. We demonstrated that the activity and specific activity can be sufficiently high under this scheme with the help of upcoming kHz lasers. The investigation of laser-induced photonuclear reactions as a viable means of producing medically essential isotopes marks a significant leap toward a compact, environmentally safe, and economically feasible technology.
Experiment
A preliminary experiment was conducted at the Compact Laser Plasma Accelerator (CLAPA) laboratory of Peking University, which has a 200 TW 5 Hz Ti:sapphire laser system, to validate the feasibility of this laser-induced photonuclear method and estimate its efficiency. As shown in Fig. 1(a), monochromatic electrons accelerated by LWFA flew past various detectors before reaching the converter, and the subsequently generated bremsstrahlung photons underwent (γ, p) reactions with the target. During the experiment, the laser system was operated at moderate energy (1.8 J on the gas target), delivering laser pulses with a focused intensity of approximately 1.5×1019 W/cm2 and a full width at half maximum(FWHM) duration of 30 fs. The laser beam was set to 21 μm×23 μm FWHM at the nozzle.
-202411/1001-8042-35-11-017/alternativeImage/1001-8042-35-11-017-F001.jpg)
The gas jet emitted from the nozzle comprised 99.9% He. After being expelled at a pressure of 30 bar, it underwent supersonic expansion and LWFA upon encountering a laser pulse. The electron charge was measured using a Turbo Integrating Current Transformer (Turbo-ICT). A 20 cm×23 cm dipole magnet with a 0.8 T peak magnetic field was placed 100 cm away from the gas target to measure the electron energy spectrum. A scintillator(Gd2O2S:Tb) was placed at the entrance and exit of the magnet. A CCD imaging system with two cameras recorded the divergence and pointing angles of the beams at the entry [see the sample image in Fig. 1(b)], and the energy spectrum at the exit [see the sample image in Fig. 1(c)]. Because the decay signals of both isotopes were within the 150 keV–200 keV range and will undergo significant self-absorption within the target material, we chose our targets as 2 cm ×2 cm squares made from natTi and natZn with a thickness of 2 mm, which also secured radiation safety during experiments. A natTa converter with the same shape as the target was placed at the magnet entrance, directly facing the target, which was positioned at the magnet exit. Setting the laser repetition rate at 0.2 Hz to maintain the vacuum, we irradiated each target for 20 min with approximately 240 laser shots. Electron parameters were then analyzed, and we found that the electrons with energies exceeding 10 MeV typically carried charges ranging from 250 pC–350 pC while featuring a quasi-monoenergetic peak at around 220 MeV, and the charge within this peak was approximately 110 pC (see Fig. 1(c)).
Radioactive nuclides were detected by recording their characteristic decay signals (159 keV for 47Sc and 185 keV for 67Cu) on a high-purity germanium (HPGe) detector shielded in Pb bricks. The samples were arranged side-by-side on the detector probe for 200 min the day after irradiation. The detector efficiencies were calibrated with 152Eu and 60Co sources and were finally determined by GEANT4 simulations according to the actual spatial position during detection. The detection results, along with the background radiation spectrum, are shown in Fig. 1(e). Both characteristic signals were significant considering the measurement uncertainty. The net counts of the characteristic signals after subtracting the background radiation are listed in Table 1. A total of 801 and 84 signals were obtained for 47Scand 67Cu, respectively.
Isotopes | τ1/2(h) | Decay mode | Reaction | Signals | Yield (total) | Yield (single shot) | Calculation (single shot) |
---|---|---|---|---|---|---|---|
47Sc | 80.4 | β-,159 keV(100%) | 48Ti(γ,p) | 801(± 68) | 1.1(± 0.2) × 107 | 4.5(± 1.7) × 104 | 6.2 × 104 |
67Cu | 61.7 | β-,185 keV(49%) | 68Zn(γ,p) | 84(± 13) | 9.0(± 2.2) × 105 | 7.7(± 3.1) × 103 | 5.7 × 103 |
These data can be used to deduce the average yield from a single-shot laser shot, denoted as N, which can be derived using the following equation:
Determining the photonuclear reaction cross-section is a complicated task, and the current experimental data are only valid under specific conditions. We theoretically estimated the isotope yield to validate our experimental results and determine the most reliable cross-sections to be used in the subsequent simulation. The analytical estimation of the (γ, p) reaction yield can be obtained from
Target Optimation
The radionuclide activity produced by laser-induced bremsstrahlung γ rays depends on many parameters, including electron current, electron energy, the converter material, geometry, converter thickness, and the target. The laser acceleration process dictates various electron properties: the interaction between the electrons and the converter determines the gamma properties, and the (γ, p) reactions in the target determine the radionuclide yield and distribution. In this section, while maintaining the experimental acceleration conditions, the gamma generation and photonuclear reaction processes are optimized by refining the parameters of the converter and the target. The laser acceleration process is discussed in the next section.
The key component of the gamma generation process is the bremsstrahlung converter, which transforms electron energy into photon energy. The conversion efficiency between the electron and photon energies depends strongly on the atomic number of the material; therefore, converters are usually made of high-Z metals such as tantalum or tungsten. The bremsstrahlung interaction generates a broad spectrum of photon energies, ranging from zero to the energy of the incoming electron beam. This photon spectrum exhibits a gradual decrease in the photon flux as the photon energy increases, tapering off entirely at the maximum photon energy. In our case, photons within the energy range of 8 MeV–35 MeV hold particular significance owing to the substantial enhancement of photonuclear cross-sections in this domain of the giant dipole resonance. Because bremsstrahlung is produced and attenuated by the converter, the optimal converter thickness can be determined for any given electron beam energy and specific converter material. This optimum thickness corresponds to a peak in the number of photons within the critical energy range, signifying the maximal yield of the photons of interest. Using tantalum as the conversion material and fixing the electron charge at 100 pC, we conducted a parameter scan of the converter thicknesses across various electron energies using the Geant4 simulation method. The number of photons exiting from the back of the converter when choosing different thicknesses and electron energies is shown in Fig. 2. The optimal thickness of the conversion material increases as the electron energy increases, as shown by the white dashed line. For instance, at 100 MeV, the optimal thickness was approximately 8 mm, extending to 10 mm at 200 MeV. Therefore, for LWFA, the thickness of the conversion material can be approximated based on the location of the electron quasi-monoenergetic peak. As the electron energy increases, the growth rate of GDR photons gradually declines, which naturally leads us to explore the relationship between electron energy and isotope yield in the subsequent paragraph.
-202411/1001-8042-35-11-017/alternativeImage/1001-8042-35-11-017-F002.jpg)
The electron parameters validate the effectiveness of the laser acceleration process and determine the conditions of the photonuclear reactions, making electrons the focal point of the entire scheme. Suppose we know the reaction yield caused by monoenergetic incident electrons of varying energies and the energy spectrum of laser-accelerated electrons. In this case, we could quickly compute the isotope yield under different laser parameters using the following integration:
Isotopes | Target | Atoms per shot | Time (h) | Rate (kHz) | Activity (MBq) | Specific activity (MBq/g) |
---|---|---|---|---|---|---|
47Sc | natTi | 6.1 × 106 | 8 | 1 | 412 | 26 |
67Cu | 68Zn | 1.9 × 106 | 15 | 1 | 306 | 16 |
-202411/1001-8042-35-11-017/alternativeImage/1001-8042-35-11-017-F004.jpg)
-202411/1001-8042-35-11-017/alternativeImage/1001-8042-35-11-017-F003.jpg)
A primary advantage of laser-induced photonuclear radioisotope generation is that all reactions occur within a confined area owing to the small size of the laser focal spot and electron beam. This implies that we can achieve a significantly higher specific activity required for most medical radioisotopes if suitable target dimensions are selected. For example, in LWFA, the bubble size is typically less than 10 μm [25], implying that the electron source size does not exceed this dimension. We conducted a simulation to obtain the optimal target shape, in which the input electron spectrum matched that obtained experimentally. According to our experimental measurements, we set the electron-source size to 5 μm and the divergence angle to 4 mrad. We then obtained the isotope distribution after one laser shot, as shown in Fig. 4; the white dashed line indicates the scheme that maximizes the specific activity while retaining over half of the radioactivity; we stick to a cylindrical shape for engineering property considerations. Following the irradiation scheme mentioned in the previous paragraph, the specific activity can ultimately accumulate to 26 MBq/g for 47Sc, and 16 MBq/g for 67Cu under the experimental electron spectrum (300 pC over 10 MeV with a quasi-monoenergetic peak at 220 MeV). This is more than sufficient for typical medical use [15].
Electron Optimization
We optimized the converter and target properties in the previous section to enhance the isotope yield under the experimental electron conditions. Next, we demonstrate that by adjusting the mechanism of the laser acceleration process, the improvement in electron charge and energy significantly reduces the repetition frequency requirements, leading us to be much closer to practical applications.
The LWFA regime is prevalent for electron acceleration in underdense plasma conditions, as was the case in our experiment. As the plasma density increases and gradually approaches the critical density, the direct laser acceleration (DLA) regime assumes dominance. Previous studies [26, 27] have indicated that in near-critical density plasmas, by choosing a matched size that maximizes the conversion efficiency from laser to energetic electrons, a typical 200 TW laser can generate high-energy (>10 MeV) electrons on the order of 10s nC through the hybrid of these two acceleration mechanisms. The matching conditions can be expressed as [27]
The open-source PIC code SMILEI [28] is used to simulate the electron acceleration process. The 3D simulations assume a linearly polarized femtosecond Gaussian laser pulse with a wavelength of 800 nm. The laser adheres to typical parameters resembling a 200 TW table-top laser system with fixed energy (
The simulation results are shown in Fig. 5. We observed that at a plasma density of 0.5nc, the dominant electron acceleration mechanism is the direct laser acceleration mechanism, characterized by a large charge but relatively low energy, whereas at 0.005nc, the dominant mechanism is the LWFA, which achieves a peak at higher energy levels but with a lower charge. As discussed in the previous section, the isotope yield increased linearly with charge and logarithmically with energy. If these two factors cannot simultaneously achieve their maximum values, we aim to make the right trade-off to maximize the yield. At 0.1nc, a hybrid acceleration mechanism combining LWFA and DLA enables a significant charge and relatively high energy in the electrons. When these electron energy spectra were inputted into Geant4 for the simulation, the 0.1nc condition resulted in the maximum yield. Setting the converter thickness to 12 mm according to Fig. 2 generated 7.9 × 107 47Sc and 2.6 × 107 67Cu per laser shot. Compared with the results in the previous section, the yield increased by more than tenfold.
-202411/1001-8042-35-11-017/alternativeImage/1001-8042-35-11-017-F005.jpg)
Figure 6 depicts the cumulative activity obtained as a function of irradiation time with the laser frequency set at 10 Hz. After irradiation for three half-lives, the activities of both isotopes surpassed 95% of their maximum values, indicating that, under optimal conditions of electron acceleration and target material parameters, both isotopes can achieve the dosage required for PET diagnostics using this regime. In particular, 47Sc required a shorter duration of approximately 50 h, whereas 67Cu required a longer duration of approximately 180 h. Moreover, the maximum activity of 47Sc reached 0.8 GBq. By employing multiple lasers simultaneously or utilizing lasers with higher repetition rates, this laser-induced generation approach could potentially satisfy the activity levels required for therapeutic purposes, whose activity requirements generally range from several GBq to tens of GBq.
-202411/1001-8042-35-11-017/alternativeImage/1001-8042-35-11-017-F006.jpg)
Conclusion
Our research confirms the viability of using laser-induced (γ, p) reactions for the production of 47Sc and 67Cu isotopes, representing a significant step toward environmentally friendly and cost-effective medical isotope generation. The compactness of high-intensity laser systems enables decentralized production, addressing the logistical challenges of isotope transportation, and minimizing radioactive waste. The precise control over the reaction zone ensures the high specific activity of the produced isotopes, which is crucial for medical applications.
Given that stable long-term kHz operations of LWFAs have already been reported [29] and an increasing number of high-charge laser electron acceleration experiments have been conducted [30], laser-induced (γ, p) 47Sc and 67Cu generation holds significant potential. If, in the future, electron acceleration in NCD plasma can be combined with kHz lasers, the diagnostic activity can be reached within a few hours and therapeutic doses of medical isotopes can be generated. The methodology employed in this study can be readily extended to other photonuclear reactions.
Commissioning of laser electron gamma beamline slegs at ssrf
. Nucl. Sci. Tech. 33, 87 (2022). https://doi.org/10.1007/s41365-022-01076-0Photonuclear production of medical isotopes 62,64Cu using intense laser-plasma electron source
. Matter Radiat. at Extremes 4,Photo-excitation production of medically interesting isomers using intense-ray source
. Appl. Radiat. Isotopes 168,Experimental study of medical isotopes 62,64cu and 68ga production using intense picosecond laser pulse
. Plasma Phys. Contr. F. 65,Transmutation prospect of long-lived nuclear waste induced by high-charge electron beam from laser plasma accelerator
. Phys. Plasmas 24,Laser-based photonuclear production of medical isotopes and nuclear waste transmutation
. Plasma Phys. Contr. F. 64,Photo-transmutation of long-lived radionuclide 135Cs by laser-plasma driven electron source
. Laser Part. Beams 34, 433-439 (2016). https://doi.org/10.1017/S0263034616000318Photonuclear production of nuclear isomers using bremsstrahlung induced by laser-wakefield electrons
. Nucl. Sci. Tech. 34, 74 (2023). https://doi.org/10.1007/s41365-023-01219-xMeasurement of 76Se and 78Se (γ, n) Cross Sections
. J. Nucl. Sci. Technol. 48, 1017-1024 (2011). https://doi.org/10.1080/18811248.2011.9711787Measurements of the 152Srn(γ,n) Cross Section with Laser-Compton Scattering γ Rays and the Photon Difference Method
. J. Nucl. Sci. Technol. 44, 938-945 (2007). https://doi.org/10.1080/18811248.2007.9711333New measurements of 92Mo(γ, n) and (γ, 3n) reactions using laser-driven bremsstrahlung γ-ray
. Aip. Conf. Proc. 11,Cross section measurements of 27Al(γ, x)24Na reactions as monitors for laser-driven bremsstrahlung γ-ray
. Nucl. Phys. A 1043,Highly Enriched Uranium-Free Medical Radioisotope Production Methods: An Integrative Review
. Applied Sciences 12, 12569 (2022). https://doi.org/10.3390/app122412569Photonuclear production of medical radiometals: a review of experimental studies
. J. Radioanal. Nucl. Ch. 328, 493-505 (2021). https://doi.org/10.1007/s10967-021-07683-2Target optimization for the photonuclear production of radioisotopes
. Appl. Radiat. Isotopes 96, 162-167 (2015). https://doi.org/10.1016/j.apradiso.2014.12.003Review: Production of nuclear medicine radioisotopes with ultra-intense lasers
. AIP Adv. 11,Promising prospects for 44Sc-/47Sc-based theragnostics: Application of 47Sc for radionuclide tumor therapy in mice
. J. Nucl. Med. 55, 1658-1664 (2014). https://doi.org/10.2967/jnumed.114.14161467Cu Production Capabilities: A Mini Review
. Molecules 27, 1501 (2022). https://doi.org/10.3390/molecules27051501The implementation of indigenous peoples education (IPED) program: towards a proposed plan of action
.Photonuclear production of the medical isotope 67Cu
. Nucl. Instrum. Methods Phys. Res., Sect. B 498, 48-51 (2021). https://doi.org/10.1016/j.nimb.2021.04.016Copper-67 as a therapeutic nuclide for radioimmunotherapy
. Eur. J. Nucl. Med. Mol. I. 29, 821-830 (2002). https://doi.org/10.1007/s00259-001-0724-yThe Pattern of the Whole Body Distribution of Radioactive Copper (67Cu, 64Cu) in Wilson’s Disease and Various Control Groups
. QJM: An International Journal of Medicine 46, 445-462 (1977). https://doi.org/10.1093/oxfordjournals.qjmed.a067518Modern Nuclear Data Evaluation with the TALYS Code System
. Nucl. Data Sheets 113, 2841-2934 (2012). https://doi.org/10.1016/j.nds.2012.11.002Geant4-a simulation toolkit
. Nucl. Instrum. Methods Phys. Res., Sect. A 506, 250-303 (2003).Wakefield acceleration
. Reviews of Modern Plasma Physics 4, 7 (2020). https://doi.org/10.1007/s41614-020-0043-zHigh-Yield High-Efficiency Positron Generation in High-z Metal Targets Irradiated by Laser Produced Electrons from Near-Critical Density Plasmas
. Chinese Phys. Lett. 34,Generating multi-gev electron bunches using single stage laser wakefield acceleration in a 3d nonlinear regime
. Phys. Rev. ST Accel. Beams 10,Smilei: A collaborative, open-source, multi-purpose particle-in-cell code for plasma simulation
. Comput. Phys. Commun. 222, 351-373 (2018). https://doi.org/10.1016/j.cpc.2017.09.024Demonstration of stable long-term operation of a kilohertz laser-plasma accelerator
. Phys. Rev. Accel. Beams 23,Generation of 400 pC electron bunches in laser wakefield acceleration utilizing a structured plasma density profile
. Phys. Plasmas 30,The authors declare that they have no competing interests.