logo

Mitigating check valve slamming and subsequentwater hammer events for PPFS using MOC

NUCLEAR ENGINEER

Mitigating check valve slamming and subsequentwater hammer events for PPFS using MOC

TIAN Wenxi
SU Guanghui
WANG Gaopeng
QIU Suizheng
XIAO Zejun
Nuclear Science and TechniquesVol.20, No.2pp.118-123Published in print 20 Apr 2009
41705

The method of characteristic (MOC) was adopted to analyze the check valve-induced water hammer behaviors for a Parallel Pumps Feedwater System (PPFS) during the alternate startup process. The motion of check valve disc was simulated using inertial valve model. Transient parameters including the pressure oscillation, local flow velocity and slamming of the check valve disc etc. have been obtained. The results showed that severe slamming between the valve disc and valve seat occurred during the alternate startup of parallel pumps. The induced maximum pressure vibration amplitude is up to 5.0 MPa. The scheme of appending a damping torque to slow down the check valve closing speed was also performed to mitigate of water hammer. It has been numerically approved to be an effective approach.

Water hammerCheck valve slammingMethod of characteristicInertia-type valve model
Reference
[1] Giot M, Prasser H M, Dudlik A, et al. Two phase flow water hammer transients and induced loads on materials and structures of nuclear power plants (WAHAloads), FISA-2001 EU Research in Reactor Safety, Luxembourg, 2001.
[2] Gale J, Tiselj I.

Modeling of cold water hammer with WAHA code

. In International Conference on Nuclear Energy for New Europe, Portoroz, Slovenia, 2003, 214.1-214.8.
Baidu ScholarGoogle Scholar
[3] Chiu C. Trans Am Nucl Soc, 1987, 54: 289-291.
[4] Altstadt E, Carl H, Weis R.

Fluid-structure interaction experiments at the cold water-hammer test facility(CWHTF) of FZ-Rossendorf

. Jahrestagung Kerntechnik, Stuttgart, Tagungsband S. 2002, 59-64.
Baidu ScholarGoogle Scholar
[5] Griffith P. Screening reactor steam/water piping systems for water hammer, NUREG/CR-6519, U.S. NRC, 1997.
[6] Izenson M G, Rothe P H, Wallis G B. Diagnosis of condensation-induced water hammer, NUREG/CR-5220, U.S. NRC, 1988.
[7] Kaliatka A, Uspuras E, Vaisnoras M. Ann Nucl Energy, 2007, 34: 1-12.
[8] Werner B, Audrius J, Annalisa M, et al. Nucl Eng Des, 2008, 238: 1129-1145.
[9] Wylie E B, Streeter V L. Fluid Mechanics (6th edition). New York (USA): McGraw-hill Book Co., 1983.
[10] Wang X F. Water Hammer in Industrial Pipes. Beijing (China): Science press, 1995 (in Chinese).
[11] The RELAP5 Code Development Team. RELAP5/MOD3.3 Code Manual, NUREG/CR-5535, INEL-95/0174, 1995.
[12] Thorley A R D.

Check valve behaviors under transient flow conditions: a state-of-art review

. ASME J Fluids Engineering, 1987, 111: 178-183.
Baidu ScholarGoogle Scholar
[13] Weaver D S, Ziada S. ASME J Pressure Vessel Technology, 1980, 102: 146-151.