54304

Technical diagnosis system (TDS) is an important subsystem to monitor status parameters of EAST (experimental advanced superconducting tokamak). The upgraded TDS data monitoring system is comprised of management floor, monitoring floor and field floor. Security protection, malfunction record and analysis are designed to make the system stable, robust and friendly. During the past EAST campaigns, the data monitoring system has been operated reliably and stably. The signal conditioning system and software architecture are described.

EASTTDSdata monitoring
References
[1] Wan Yuanxi. Nucl Fus, 2000, 40: 1057-1068.
[2] Chen Z M, Cryogen Superconduct, 2007, 35(2): 93-95 (in Chinese)
[3] Qian J, Weng P D, Luo J R, et al.

Measurement system in large-scale superconducting magnet performance test

, the 21st International Conference on Magnet Technology, October 2009, Hefei, China.
Baidu ScholarGoogle Scholar
[4] Wu S T, Wu Y, Song Y T, et al. IEEE Trans. Appl. Supercon., 2009, 19(3): 1069-1080
[5] Qian J, Weng P, Luo J, et al. Comput Eng, 2008, 34(12): 212-214 (in Chinese)
[6] Schmidt V, Flor G, Hemming O N, et al. Fusion Eng, 1995, 25: 461-496.
[7] Wang L, Centioli C, Iannone F, et al. Fusion Eng, 2004, 71: 23-28.
[8] EAST physics design team, EAST Physics Design Symposium, 1998, Vol. 2. (in Chinese)
[9] SUN X, Luo J, Ji Z, et al. Nucl Tech, 2008, 31(4): 293-297 (in Chinese)
[10] SUN X, Luo J, Ji Z, et al. Nucl Fus Plasma Phys, 2008, 28(4): 352-356. (in Chinese)
[11] http://www.ni.com/signalconditioning/whatis.htm
[12] Wu S T, Wan Y. Design Collection І for EAST. Hefei: Institute of Plasma Physics, Chinese Academy of Sciences, 1998 (in Chinese)
[13] Chen W. Design analysis of TF magnet structure and magnet experimental study for EAST. Hefei: Institute of Plasma Physics, Chinese Academy of Sciences, 2002. 42-50. (in Chinese)