logo

A precise time measurement evaluation board for a radiography system of high-Z materials

LOW ENERGY ACCELERATOR AND RADIATION APPLICATIONS

A precise time measurement evaluation board for a radiography system of high-Z materials

DOU Fei
LIANG Hao
ZHOU Lei
ZHOU Yongzhao
Nuclear Science and TechniquesVol.23, No.5pp.284-288Published in print 20 Oct 2012
39300

The time resolution of a radiography system for high-Z materials shall be at least 1 ns, hence the need of a time measurement system with a resolution of about 100 ps. In this paper, a Time Measurement Evaluation Board (TMEB) is developed to meet the need. It is based on the time-to-digital converter of ACAM TDC-GP2. Test results show an overall time resolution of 81 ps in detecting cosmic-rays with a plastic scintillator.

RadiographyTime measurementTDCCFDResolutionLinearity
References
[1] Hohlmann M, Ford P, Gnanvo K. IEEE Trans Nucl Sci, 2009, 56: 1356-1363.
[2] Borozdin K N, Hogan G E, Morris C. Nature, 2003, 422: 277-277.
[3] Priedhorsky W C, Borozdin K N, Hogan G E. Rev Sci Instrum, 2003, 74: 4294-4297.
[4] Schultz L J, Borozdin K N, Gomez J J. Nucl Instrum Meth Phys Res A, 2004, 519: 687-694.
[5] Xie Y G, Chen Ch, Wang M. Particle detectors and data acquisition, Beijing (China): Science Press, 2003, 91-104.
[6] Yang T, Zhao B, Zhang Ch. Nucl Electr Detect Technol, 2002, 5: 244-246.
[7] TDC-GP2.2-channel Universal Time-to-Digital Converter, version2.0, May, 2010.
[8] Zhang Y H, Li F, Jin G. Nucl Tech, 2007, 3: 227-230.