logo

Experimental test of a new neutron threshold detector and its application

Experimental test of a new neutron threshold detector and its application

LI Gui-Sheng
ZHANG Tian-Mei
SU You-Wu
LI Shu-Wei
Nuclear Science and TechniquesVol.13, No.3pp.149-155Published in print 01 Aug 2002
31300

The possibility of using 209Bi as a new threshold detector to measurc high-energy neutrons was investigated for the first time. At the same time the experiment measured successfully the emitted neutron fiuence rate, energy spectrum and dose equivalent rate distributions in the heavy ion target area using a detector complex including 209Bi, 115In, 27Al, 19F and 12C samples.

209Bi threshold detectorExperimental testNeutron spectrumFluence rateDose equivalent rate
References
1 Liu S K. Neutron Physics (in Chinese ), Beijing; Atomic Energy Press, 1986
2 Cecil R A, Anderson B D, Baldwin A R et al. Phys Rev, 1981, C24: 2013
3 Kazuo SHIN, Takatsugu SAITO, Masahiko FUJII Nucl Instr Meth, 1981, 187: 587
4 Broome T A, Perry D R, Stapleton G S. Health Phys, 1983, 44(5): 487
5 Li G S, Zhang T M, Li Z W et al. Nucl Instr Meth, 1998, A404: 349
6 LI G S, Zhang T M, Li Z W et al. Nucl Instr Meth, 2000, A452: 454
7 Charalambus St, Dutrannois J, Goebel K. CERN/DI/HP 90, 1966
8 Imamura M, Shibata S, Uwamino Y et al.

JAERI TIARA Annual Report, 1994.5: 1995.205

Baidu ScholarGoogle Scholar
9 ICRP Conversion Coefficients for use in Radiological Protection against External Radiation. ICRP Publication, Vol. 74, Oxford: Pergamon Press, 1996