Vapor-water two-phase low friction pressure drop in helically boiled tubes
. In:
Experimental study on steam-water two-phase flow frictional pressure drops in helical coils
Experiments of steam-water two-phase flow frictional pressure drop in a vertical helical coil were carried out in the high-pressure water test loop of Xi'an Jiaotong University, The coil is made of stainless steel tube with an inner diameter of 16 mm, the helix diameter measured from tube axis to tube axis is 1.3 m, and helix angle of the coil is 3.65°. The experimental conditions are: pressure p=4~18MPa, mass velocity G=400~1400 kg/ (m2·s) , inner wall heat flux q=100~700 kW/m2. Based on these data, a correlation for predicting the steam-water two-phase flow frictional pressure drop was derived, it can be used for the design of steam generator of HTGR.
Vapor-water two-phase low friction pressure drop in helically boiled tubes
. In: