1 Introduction
Neutron-induced reactions play an essential role in the synthesis of the heavy elements of the universe, and approximately half of the chemical elements heavier than iron are produced by the slow neutron capture process (s process) in stars [1-4]. Most neutron capture cross-sections are measured relative to the cross-section standards and normalized to absolute values. To date, the cross section of the 197Au(n, γ) reaction with thermal neutron energy up to 2.5 MeV is the only capture criterion, while most neutron capture cross-section measurements refer to one or both energy regions [5]. Using the standard neutron capture cross-section data from the ENDF/B-VIII.0 database [6], we can check the feasibility of our experimental setup and method.
We use the C6D6 detector system to measure the decay of gamma rays emitted from the compound nucleus owing to its low sensitivity to neutrons and short response time [7]. The 197Au(n, γ) cross section was measured from 1 eV to 100 keV owing to the influence of the gamma flash from a white neutron source at high neutron energy regions. We then analyzed the experimental data using the pulse height weighting technique (PHWT), and compared our experimental data with the evaluation data of the evaluated nuclear data file (ENDF). Finally, we used SAMMY code [37] to fit the experimental data in the resonance energy range from 1 eV to 1 keV and extracted the corresponding resonance parameters.
The remainder of this paper is organized as follows: A detailed introduction of the C6D6 detector system at Back-n is given in Sect. 2. The raw data analysis using the PHWT method for neutron capture cross-sections is presented in Sect. 3. Finally, conclusions and uncertainty analysis are presented in Sect. 4.
2 Measurements
The China Spallation Neutron Source (CSNS) [9, 10] is the first spallation neutron source facility that provides a pulsed neutron beam with energy from thermal energy to 400 MeV in China [11, 12]. The neutron beam is produced through the pulses of protons with an energy of 1.6 GeV and a pulse frequency of 25 Hz, bombarding a tungsten (W) target. The Back-n white neutron beamline is constructed 180 to the proton beam direction, and the neutron flux can reach up to 107 n/cm2/s at the experimental station (ES). There are two experimental stations on the Back-n beamline, as shown in Fig. 1; ES#1 is approximately 55 m from the spallation target, which mainly studies the (n, lcp (light charge particle)) reaction cross section, and ES#2 is approximately 76 m, which is mainly for the measurements of (n, γ), (n, tot), and (n, f) reactions cross sections [13-16].
-202109/1001-8042-32-09-013/alternativeImage/1001-8042-32-09-013-F001.jpg)
2.1 The C6D6 detector system in Back-n neutron beamline
The Back-n C6D6 detector system consists of four C6D6 liquid scintillation detectors, one aluminum detector’s brackets, and one aluminum sample holder, as shown in Fig. 2. The C6D6 detectors are placed upstream of the neutron beam sample target to decrease the elastic scattering neutron background, and the detector axis is at an angle of 110 °from the neutron beam. The distance between the C6D6 detectors front center to the sample target center was 150 mm and 80 mm from the neutron beam axis.
-202109/1001-8042-32-09-013/alternativeImage/1001-8042-32-09-013-F002.jpg)
The C6D6 detector is a liquid scintillator EJ315 [17] produced by the ELJEN Technology Corporation. The shell of the scintillator shell is made of aluminum owing to its low capture rate, with a diameter and length of 130 mm and 76.2 mm, respectively. The structure of the detector system used in the Geant4 simulation is shown in Fig. 3.
-202109/1001-8042-32-09-013/alternativeImage/1001-8042-32-09-013-F003.jpg)
In the neutron capture cross-section measurements, the amplitude of the anode signals of the C6D6 detectors is from 0.01 to 3 V. Signals from the C6D6 detectors are delivered to the readout electronics, which can digitize the analog signals into a full waveform with a 1 GS/s sampling rate and 12 bits resolution [18]. The neutron start time T0 signals are picked up by the pulsed proton beam, while the stop time Ts of the neutrons that have reacted in the sample is picked up by the C6D6 detectors; further, the electronics record these signals so that the incident neutron energy can be determined using the time-of-flight (TOF) technique. The energy of the incident neutron (En) is given by Eq. (1), and the neutron energy resolution is calculated using Eq. (2) [19],
where the flight length L = L0+Δ L(En), L0 is the geometric distance from the spallation target to the sample, and Δ L(En) is the equivalent change in moderation length associated with the incident neutron energy. En, L, and tof=Ts-T0 are in units of MeV, m, and ns, respectively.
In addition, the setup of the capture measurements is complemented by a silicon flux monitor (SiMon); the SiMon consists of a thin 6LiF conversion layer and eight silicon detectors outside the neutron beam (Li-Si Monitor) to count the number of neutrons by detecting alpha particles and 3H through the reaction 6Li(n, α)3H [20].
2.2 Samples
The gold sample(Au) with Φ 50舁mm × 1舁mm, natural C sample with Φ 50舁mm × 1舁mm, and natural Pb sample (an additional experiment with a proton power of 80 kW) with Φ 30舁mm × 0.53舁mm are shown in Table 1. The natC and empty samples were used for background subtraction in our experiment because of sample scattered neutrons and γ rays from the surroundings, and the natPb sample was used for subtracting the in-beam γ-ray background.
Sample | Diameter(mm) | Thickness(mm) | Weight(g) | Area(cm2) | Area density Atoms/Barn |
---|---|---|---|---|---|
197Au | 50 | 1 | 37.93 | 19.63 | 5.907×10-3 |
natC | 50 | 1 | 4.42 | 19.63 | 1.128×10-2 |
natPb | 30 | 0.53 | 4.24 | 7.07 | 1.748×10-3 |
Empty target | - | - | - | - | - |
3 Analysis of the C6D6 data
The C6D6 detector system is one of the total energy detection systems primarily used for neutron capture cross-section measurements [19]. Because of the low detection efficiency of γ rays and the detection efficiency being directly proportional to the γ ray energy, the pulse height weighting technique (PHWT) was used in the data analysis.
3.1 From measured count rate to capture yield
The experimental yield Yexp is obtained as a function of the neutron energy En from the weighed rate NW through the PHWT [21, 22]
where Yexp, NW, and the neutron intensity I depend on the TOF or neutron energy; the weighted count rate NW is described in the following sections. The neutron intensity I(En) is proportional to the total number of neutrons interacting with the sample with energy En, as shown in Fig. 4. The fixed fraction fN is the yield normalization factor for flux calibration, which was normalized to one at 4.9 eV owing to the saturated resonance of the thick gold sample. Ec represents the total capture energy, which for the kinetic energy En of the center-of-mass frame is given by Ec = En + Sn, where Sn=6.512 MeV is the neutron separation energy of the compound nuclei 198Au.
-202109/1001-8042-32-09-013/alternativeImage/1001-8042-32-09-013-F004.jpg)
3.2 Pulse height weighting technique
In 1963, Moxon and Rae [24] first proposed the principle of the PHWT and constructed a simple gamma detector consisting of a carbon disk and a thin plastic scintillator. Macklin and Gibbons [25] first applied a pair of C6F6 detectors to neutron capture cross-section studies in 1967. Using this technique, the detection efficiency is proportional to the gamma energy; thus, ϵγ = c·Eγ. Because and Ec = En + Sn, the capture efficiency ϵc can be written as [7]
To validate the equation, we introduced the weighting function (WF)W(Ei) as follows:
The WFs used for the present measurements were obtained from the response functions of mono-energetic γ-rays, which were calculated using Monte Carlo simulations of the experimental setup with Geant4.10.06 [26-28]. The simulated γ-rays with energies ranging from 0.15 to 7 MeV were produced from the volume (surface) of the gold sample, and then emitted homogeneously; further, part of the gamma ray was deposited energy in the C6D6 detectors. The simulated γ-ray energy deposition spectrum or pulse height (PH) spectrum is shown in Fig. 5; the energy threshold was 100 keV. Moreover, the original detection efficiency of the primary C6D6 setup is approximately 2%, the weighted efficiency has a fixed linear relationship with γ-ray energy, and the ratios of each energy point are very close to those shown in Fig. 6a. We compared the γ-rays emitted from the volume of the gold sample and from the surface of the sample, and there was little difference between the two modes of emissions.
-202109/1001-8042-32-09-013/alternativeImage/1001-8042-32-09-013-F005.jpg)
-202109/1001-8042-32-09-013/alternativeImage/1001-8042-32-09-013-F006.jpg)
The χ2 method is applied to ensure that the WF parameters ak use gamma-ray energy ranging from 0.15 to 7 MeV, as shown in Eq. (5) or Eq. (6)
Usually, the constant factor c is set to one, and or is the response function of the detectors of the jth γ-rays with an energy of Eγ j from the Geant4 simulation, Ed is the deposion gamma energy, and Δ E denotes the γ energy bin width of 10 keV. The weight function is solved by the ROOT Minuit method shown in Fig. 6b.
3.3 From capture yield to cross section
In the experiment, we measured data from the gold sample, carbon sample to subtract the elastic scattering contribution, empty sample (beamOn) to subtract the ambient background, and lead sample to subtract the in-beam γ background. The raw counts from the experiment shown in Fig. 7a were normalized to the SiMon rate. The experimental capture yield, as shown in Fig. 7b, was normalized to a single neutron using the counts of the SiMon detectors. The weighted counts NW of the gold sample were deduced from the ambient background through the empty sample (beam on), neutron elastic scattering background through the carbon sample, and in-beam c-ray background through the natural lead sample, as expressed by Eq. (7), where Nnet, NBkg, NC, and NPb are the sample counts after subtracting the background, empty sample counts, natural carbon sample counts, and natural Pb sample counts, respectively. W is the weighting function of the detector system, and η is directly proportional to the product of the number of target nuclei per unit area and the elastic scattering cross section of the sample. In theory, the multiple scattering and self-shield-corrected capture yield [5, 21] is related to the capture cross section rc, total cross section σt (from ENDF’s evaluated database), density of the sample n, thickness of the sample t, and fixed factor fc of the sample thickness, which is related to the capture cross sections, as shown in Eq. (8).
-202109/1001-8042-32-09-013/alternativeImage/1001-8042-32-09-013-F007.jpg)
The experimental capture yield, as shown in Fig. 7b, was normalized to a single neutron using the counts of the SiMon detectors. The weighted counts NW of the gold sample were deduced from the ambient background through the empty sample (beam on), neutron elastic scattering background through the carbon sample, and in-beam γ-ray background through the natural lead sample, as expressed by Eq. (7), where Nnet, NBkg, NC, and NPb are the sample counts after subtracting the background, empty sample counts, natural carbon sample counts, and natural Pb sample counts, respectively. W is the weighting function of the detector system, and η is directly proportional to the product of the number of target nuclei per unit area and the elastic scattering cross-section of the sample. In theory, the multiple scattering and self-shield-corrected capture yield [5, 19] is related to the capture cross section σc, total cross section σt (from ENDF’s evaluated database), density of the sample n, thickness of the sample t, and fixed factor fc of the sample thickness, which is related to the capture cross sections, as shown in Eq. (8).
Then, combined with the experimental capture yield Yexp(En), the present experimental capture cross-section formula is as follows:
Considering the multi-elastic scattering of neutrons in the thick sample, we introduced the factor fc, which is related to the sample’s absorption cross-section and the thickness of the sample. The factor fc is defined in Eq. (10). It is the ratio of the mean neutron transmission length (the addition of all step lengths extracted from the Geant4 simulation) to the target thickness t.
Fig. 8 shows the Geant4 simulated results of gold targets with thicknesses of 0.1 mm and 1 mm and neutrons with energy in the range from 0.1 eV to 100 keV. The negative peaks show strong resonance absorption, such as 4.9 eV (the first resonance peak in 197Au target). The regions of the positive peaks indicate that neutrons multi-scattered in those elastic scattering energy regions. Thus, the sufficient thickness of the sample () is larger than the thickness of the target when the factor fc larger than one.
-202109/1001-8042-32-09-013/alternativeImage/1001-8042-32-09-013-F008.jpg)
4 conclusions and uncertainty analysis
The 197Au(n, γ) reaction cross section was experimentally measured with neutrons with energy from 1 eV to 100 keV, and the results were in good agreement with the latest 197Au standard evaluated capture cross sections ENDF/B-VIII.0 [29], CENDL-3.1 [30], and JENDL-4.0 [31] in the entire tested energy region, as shown in Fig. 9. More detailed results in the resolved resonance region(RRR) are shown in Fig. 10a and Fig. 10b, which indicates that this work has a good energy resolution. Among the peak values of the energy points, the present results are larger than those of the ENDFs owing to the background in the experiment, which cannot be deducted completely [32-35]. Fig. 10c indicates that there are many resonances in the region of 2-5 keV in the experimental data, as well as in the CENDL-3.1 data, while the average cross-section data is still used in the ENDF/B-VIII.0 database for this region. In addition, the present data in the unresolved resonance region (URR) from 10 keV to 100 keV are generally in agreement with those of the evaluated databases, Lederer’s data [36] in 2011 and Massimi’s data [37] in 2014 shown in Fig. 10d. Finally, the R-matrix code SAMMY(R6) [8] in the Reich-Moore multi-level approximation was used to analyze the resonance shape of the capture cross section in the energy region from 1 eV to 1 keV. The analysis included self-shielding and multiple corrections, and Doppler broadening with an effective temperature of 300 K using the free gas model (FGM). The R-matrix fitting results were in agreement with the experimental data shown in Fig. 11). The fitting resonance parameters of the resonance energy (ER), gamma width (Γγ), and neutron width (Γn) are listed in Table 2.
ER (eV) | l | Jπ | Γγ (meV) | Γn (meV) | ||||
---|---|---|---|---|---|---|---|---|
This work | ENDF/B-VIII.0 | n_TOF | This work | ENDF/B-VIII.0 | n_TOF | |||
4.904 | 0 | 2+ | 119.0 | 121.4 | 124.0 | 16.01 | 14.96 | 15.2 |
.70 | 0 | 1+ | 132.0 | 127.0 | 128.0 | 0.190 | 0.220 | 0.223 |
.08 | 0 | 1+ | 111.7 | 113.0 | 112.0 | 4.55 | 4.31 | 4.34 |
.31 | 0 | 2+ | 113.5 | 118.0 | 110.0 | 88.80 | 70.66 | 73.9 |
.53 | 0 | 1+ | 118.5 | 124.0 | 120.0 | 25.59 | 17.00 | 17.79 |
.04 | 0 | 2+ | 110.2 | 123.0 | 110.0 | 10.31 | 7.83 | 8.29 |
.25 | 0 | 2+ | 128.0 | 121.0 | 128.0 | 0.730 | 0.900 | 0.86 |
.46 | 0 | 1+ | 121.0 | 121.0 | 120.0 | 3.90 | 9.07 | 9.35 |
.42 | 0 | 2+ | 150.0 | 121.0 | 150.0 | 36.15 | 22.26 | 21.6 |
.13 | 0 | 1+ | 197.0 | 129.0 | 197.0 | 67.88 | 55.16 | 42.5 |
.25 | 0 | 2+ | 109.0 | 121.0 | 109.0 | 7.17 | 9.98 | 8.67 |
.04 | 0 | 1+ | 132.0 | 121.0 | 130.0 | 58.98 | 49.08 | 49.8 |
.21 | 0 | 1+ | 178.0 | 121.0 | 180.0 | 0.473 | 0.860 | 0.860 |
.65 | 0 | 2+ | 99.6 | 121.0 | 99.6 | 74.17 | 74.16 | 86.6 |
.82 | 0 | 1+ | 124.0 | 124.0 | 130.0 | 0.204 | 0.561 | 0.500 |
.26 | 0 | 1+ | 129.0 | 129.0 | 124.0 | 325.6 | 144.0 | 152.0 |
.95 | 0 | 2+ | 121.0 | 121.0 | 110.0 | 1.58 | 4.83 | 4.41 |
.56 | 0 | 2+ | 135.7 | 126.0 | 123.6 | 587.2 | 364.0 | 348.0 |
.39 | 0 | 2+ | 137.0 | 137.0 | 137.0 | 31.56 | 46.0 | 41.5 |
.92 | 0 | 1+ | 130.0 | 130.0 | 130.0 | 45.19 | 62.18 | 56.2 |
.25 | 0 | 2+ | 125.0 | 125.0 | 125.0 | 24.46 | 40.00 | 37.6 |
.36 | 0 | 2+ | 121.0 | 121.0 | 99.0 | 289.7 | 85.88 | 109.0 |
.20 | 0 | 1+ | 121.0 | 121.0 | 125.0 | 4.77 | 13.92 | 12.3 |
.13 | 0 | 2+ | 98.0 | 121.0 | 97.0 | 45.15 | 63.11 | 73.9 |
.27 | 0 | 2+ | 128.0 | 128.0 | 128.0 | 6.83 | 6.83 | 6.08 |
.68 | 0 | 1+ | 140.0 | 140.0 | 140.0 | 19.35 | 26.96 | 25.8 |
.45 | 0 | 1+ | 150.0 | 150.0 | 149.0 | 650.5 | 297.3 | 281.4 |
.15 | 0 | 2+ | 111.0 | 128.6 | 110.0 | 28.14 | 63.50 | 63.7 |
.60 | 0 | 2+ | 124.0 | 137.1 | 124.9 | 927.0 | 317.0 | 296.1 |
.90 | 0 | 1+ | 138.0 | 138.0 | 138.0 | 17.68 | 60.83 | 62.2 |
.98 | 0 | 2+ | 110.0 | 121.0 | 111.0 | 10.36 | 28.16 | 28.5 |
.13 | 0 | 2+ | 130.0 | 130.0 | 130.0 | 9.01 | 66.01 | 31.8 |
.58 | 0 | 1+ | 128.0 | 121.0 | 127.0 | 19.45 | 62.14 | 58.6 |
.68 | 0 | 2+ | 128.0 | 128.0 | 128.0 | 3.36 | 2.95 | 2.44 |
.26 | 0 | 2+ | 126.6 | 155.6 | 126.0 | 647.2 | 358.7 | 288.4 |
.16 | 0 | 1+ | 123.0 | 114.7 | 122.0 | 306.8 | 146.2 | 306.8 |
.84 | 0 | 2+ | 134.0 | 134.0 | 134.0 | 22.86 | 23.86 | 22.4 |
.99 | 0 | 2+ | 112.5 | 119.5 | 113.0 | 42.70 | 227.4 | 223.9 |
.37 | 0 | 1+ | 313.6 | 127.5 | 135.0 | 128.3 | 128.3 | 111.0 |
.72 | 0 | 1+ | 121.0 | 121.0 | 121.0 | 20.8 | 30.86 | 53.4 |
.23 | 0 | 2+ | 138.0 | 121.0 | 138.0 | 11.55 | 50.15 | 24.7 |
.96 | 0 | 2+ | 120.0 | 132.1 | 118.5 | 510.7 | 510.6 | 464.0 |
.16 | 0 | 2+ | 97.0 | 97.0 | 97.0 | 1.04 | 4.84 | 4.20 |
.27 | 0 | 1+ | 128.0 | 128.0 | 128.0 | 6.64 | 19.89 | 16.8 |
.04 | 0 | 1+ | 142.5 | 159.1 | 139.0 | 699.8 | 716.4 | 666.7 |
.44 | 0 | 2+ | 244.2 | 111.3 | 110.0 | 800.0 | 699.8 | 736.1 |
.88 | 0 | 2+ | 112.0 | 121.0 | 112.0 | 17.96 | 114.4 | 110.0 |
.72 | 0 | 1+ | 120.0 | 120.0 | 120.0 | 1.76 | 12.08 | 10.6 |
.16 | 0 | 1+ | 113.0 | 119.0 | 110.0 | 34.97 | 411.6 | 426.7 |
.04 | 0 | 1+ | 127.0 | 136.0 | 125.0 | 480.9 | 431.9 | 474.6 |
.62 | 0 | 2+ | 140.0 | 140.0 | 140.0 | 20.74 | 110.3 | 14.0 |
.40 | 0 | 2+ | 124.0 | 142.0 | 123.0 | 178.0 | 157.8 | 177.6 |
.81 | 0 | 1+ | 128.0 | 128.0 | 128.0 | 15.46 | 24.11 | 22.1 |
.78 | 0 | 2+ | 128.0 | 128.0 | 128.0 | 240.0 | 253.9 | 232.0 |
.56 | 0 | 2+ | 155.3 | 134.8 | 117.0 | 560.0 | 523.1 | 426.4 |
.10 | 0 | 2+ | 121.0 | 121.0 | 107.0 | 4.90 | 20.94 | 18.4 |
.18 | 0 | 2+ | 66.0 | 121.0 | 66.0 | 6.43 | 30.92 | 35.2 |
.61 | 0 | 2+ | 126.0 | 134.7 | 124.0 | 754.2 | 429.8 | 340.0 |
.27 | 0 | 2+ | 128.0 | 121.0 | 128.0 | 2.40 | 6.18 | 6.30 |
.51 | 0 | 2+ | 150.0 | 157.3 | 150.0 | 9.01 | 49.2 | 49.2 |
.85 | 0 | 2+ | 125.5 | 116.3 | 94.0 | 586.0 | 327.8 | 250.0 |
.89 | 0 | 2+ | 160.0 | 121.0 | 160.0 | 34.28 | 125.2 | 94.0 |
.81 | 0 | 2+ | 131.0 | 121.0 | 130.0 | 505.1 | 505.0 | 350.0 |
-202109/1001-8042-32-09-013/alternativeImage/1001-8042-32-09-013-F009.jpg)
-202109/1001-8042-32-09-013/alternativeImage/1001-8042-32-09-013-F010.jpg)
-202109/1001-8042-32-09-013/alternativeImage/1001-8042-32-09-013-F011.jpg)
The 197Au(n, γ) neutron capture cross section was measured at the Back-n neutron beamline of the CSNS, which is aimed at verifying the rationality of the new C6D6 setup for neutron capture cross-section measurements. The results are found to be in good agreement with those of the ENDFs and other evaluation data and the n_TOF experimental data, especially in the resonant energy region. The statistical uncertainty of the measured 197Au(n, γ) reaction cross section is less than 2%, while the other uncertainties come from the background that is removed through the carbon and empty targets, and from the energy dependence of the neutron flux, which is the largest contribution with approximately 5% at present [23]. The other uncertainties are due to the PHWT and were 2-3%, as shown in Ref [38]. The results show that the C6D6 detectors and PHWT detection technology in the Back-n neutron beamline of CSNS is an effective detection system for capture cross-section measurements that are >100 mb, especially for the 1 eV to 100 keV low resonance energy regions.
Neutron physics with accelerators
. Prog. Part. Nucl. Phys. 101, 177 (2018). doi: 10.1016/j.ppnp.2018.02.002Reaction cross sections for the s, r, and p process
. Prog. Part. Nucl. Phys. 66, 390 (2011). doi: 10.1016/j.ppnp.2011.01.040The s process: Nuclear Physics, stellar models, and observations
. Rev. Modern Phys. 83, 157 (2011). doi: 10.1103/RevModPhys.83.157Measurement of 73Ge(n, γ) cross sections and implications for stellar nucleosynthesis
. Phys. Lett. B 790, 458-465 (2019). doi: 10.1016/j.physletb.2019.01.045197Au(n, γ) cross section in the resonance region
. Phys. Rev. C 81, 044616 (2010). doi: 10.1103/PhysRevC.81.044616Evaluated nuclear data file (ENDF)
. https://www.nndc.bnl.gov/exfor/endf00.jspThe use of C6D6 detectors for neutron induced capture cross-section measurements in the resonance region
. Nucl. Instr. Method A 577, 626 (2007). doi: 10.1016/j.nima.2007.03.034China's first pulsed neutron source
. Nat. Mater. 15, 689 (2016). doi: 10.1038/nmat4655Proposal for muon and white neutron sources at CSNS
. Chin. Phys. C 34, 121 (2010). doi: 10.1088/1674-1137/34/1/022Ionizing and non-ionizing kerma factors in sillicon for China Spallation Neutron Source neutron spectrum
. Nucl. Sci. Tech. 30, 143 (2019). doi: 10.1007/s41365-019-0664-5Back-n white neutron facility for nuclear data measurements at CSNS
. J. Instrum 12, P07022 (2017). doi: 10.1088/1748-0221/12/07/P07022Studies of back-streaming white neutrons at CSNS
. Nucl. Instrum. Methods A 621 91 (2010) doi: 10.1016/j.nima.2010.06.097Back-n white neutron source at CSNS and its applications
. Nucl. Sci. Tech. 32, 11 (2021). doi: 10.1007/s41365-021-00846-6Back-n white neutron facility at CSNS and first-year nuclear data measurements
. in Proceeding of ND2019, EPJ Web of Conferences, 239, 06002 (2020). doi: 10.1051/epjconf/202023906002EJ-315 deuterated liquid scintillator data sheet
. https://eljentechnology.com/The C6D6 detector system on the Back-n beam line of CSNS
. Radiat. Detect. Technol. Methods: 3 and 52 (2019). doi: 10.1007/s41605-019-0129-8Neutron-induced cross sections: From raw data to astrophysical rates
. Eur. Phys. J. P 133, 424 (2018). doi: 10.1140/epjp/i2018-12295-3Measurement of the 238U(n, γ) cross section up to 80 keV with the Total Absorption Calorimeter at the CERN n_TOF facility
. Phys. Rev. C 96, 064601 (2017). doi: 10.1103/PhysRevC.96.064601Measurement and analysis of the 241Am(n, γ) cross section with liquid scintillator detectors using time-of-flight spectroscopy at the n_TOF facility at CERN
. Phys. Rev. C 89, 044609 (2014). doi: 10.1103/PhysRevC.89.044609Radiative neutron capture on 242Pu in the resonance region at the CERN n_TOF EAR1 facility
. Phys. Rev. C 97, 024605 (2018). doi: 10.1103/PhysRevC.97.024605Neutron energy spectrum measurement of the Back-n white neutron source at CSNS
. Eur. Phys. J. A 55, 115 (2019). doi: 10.1140/epja/i2019-12808-1A gamma-ray detector for neutron capture cross-section measurements
. Nucl. Instr. and Meth. 24, 445 (1963). doi: 10.1016/0029-554X(63)90364-1Capture-Cross-Section Studies for 30-220 keV Neutrons Using a New Technique
. Phys. Rev. 159, 1007 (1967). doi: 10.1103/PhysRev.159.1007Geant4 – a simulation toolkit
. Nucl. Instrum. Methods A 506, 250 (2003) doi: 10.1016/S0168-9002(03)01368-8Geant4 developments and applications
. IEEE T. Nucl. Sci. 53, 270-278 (2006) doi: 10.1109/TNS.2006.869826Recent developments in Geant4
. Nucl. Instrum. Methods A 835, 186-225 (2016). doi: 10.1016/j.nima.2016.06.125IAEA, ENDF/B-VIII.0 Database, LANL
http://www-nds.iaea.org/exfor/endf.htmIAEA, CENDL-3.1 database, CNDC
http://www-nds.iaea.org/exfor/endf.htmIAEA, JENDL-4.0 database, JAEA
http://www-nds.iaea.org/exfor/endf.htmBackground study for (n, γ) cross section measurements with C6D6 detectors at CSNS Back-n
. Nucl. Instrum. Methods A 985, 164703 (2021) doi: 10.1016/j.nima.2020.164703In-beam γ-rays of back-streaming white neutron source at China Spallation Neutron Source
. Acta Physica Sinica 69(17), 172901 (2020). doi: 10.7498/aps.69.20200718 (in Chinese)Neutron capture cross section measurement of 197Au with pulse height weighting techniques
. Nuclear Techniques, 43(8), 080501 (2020). doi: 10.11889/j.0253-3219.2020.hjs.43.080501 (in Chinese)Measurement of the neutron total cross section of carbon at the Back-n white neutron beam of CSNS
. Nucl. Sci. Tech. 30, 139 (2019). doi: 10.1007/s41365-019-0660-9197Au(n, γ) cross section in the unresolved resonance region
. Phys. Rev. C 83, 034608 (2011). doi: 10.1103/PhysRevC.83.034608Neutron capture cross section measurements for 197Au from 3.5 to 84 keV at GELINA
. Eur. Phys. J. A. 50, 124 (2014). doi: 10.1140/epja/i2014-14124-8Accuracy of the pulse height weighting technique for capture cross section measurements
. Journal of Nuclear Science and Technology, 39, 689 (2002). doi: 10.1080/00223131.2002.10875193Updated Users' Guide for SAMMY: Multilevel R-matrix Fits to Neutron Data Using Bayes' Equations. Oak Ridge National Laboratory Report No. /TM-9179/R6
.A possible scheme for the surface muon beamline at CSNS
. Nucl. Sci. Tech. 30, 169 (2019). doi: 10.1007/s41365-019-0648-1