Shiping LI, Xiufeng XU, Hongrui CAO, et al. Dynamic linear calibration method for a wide range neutron flux monitor system in ITER. [J]. Nuclear Science and Techniques 24(4):040402(2013)
DOI:
Shiping LI, Xiufeng XU, Hongrui CAO, et al. Dynamic linear calibration method for a wide range neutron flux monitor system in ITER. [J]. Nuclear Science and Techniques 24(4):040402(2013) DOI: 10.13538/j.1001-8042/nst.2013.04.002.
Dynamic linear calibration method for a wide range neutron flux monitor system in ITER
As a key part of the diagnosis system in the International Thermonuclear Experimental Reactor (ITER), the neutron flux monitor (NFM), which measures the neutron intensity of the fusion reaction, is a Counting-Campbelling system with a large dynamic counting range. A dynamic linear calibration method is proposed in this paper to solve the problem of cross-over between the different counting and Campbelling channels, and improve the accuracy of the cross-calibration for long-term operation. The experimental results show that the NFM system with the dynamic linear calibration system can obtain the neutron flux of the fusion reactor in real time and realize the seamless measurement area connection between the two channels.
关键词
Keywords
Dynamic linear calibrationLong-term stabilityCross-overNeutron flux monitorInternational Thermonuclear Experimental Reactor (ITER)
references
Yang J W, Yang Q W, Xiao G S, et al. Plasma Sci Tech, 2008, 10: 141-147.
Lescop B, Normand S, Jean C T, et al. Nuclear science symposium conference record, IEEE, 2004, 3: 1567-1570.
Geslot B, Unruh T C, Philippe F, et al. Nucl Sci, 2012, 59: 1377-1381.
Yamauchi M, Nishitani T, Ochiai K, et al. Rev Sci Instrum, 2003, 74: 1730-1734.
Yang J W, Yang Q W, Yuan G L, et al. Plasma Sci Tech, 2008, 10: 676-680.
Jassby D L, Barnes C W, Bitter M, et al. Rev Sci Instrum, 1999, 70: 1111-1114.
Zhong G Q, Hu L Q, Li X L, et al. Plasma Sci Tech, 2011, 13: 162-166.
Cao H R, Li S P, Xu X F, et al. Nucl Sci Tech, 2012, 23: 114-117.
Cao H R, Li S P, Xu X F, et al. Plasma Sci Tech, 2011, 14: 1008-1010.
Takal H, Takeo N, Atsuhiko M, et al. Rev Sci Instrum, 2008, 79: 1063-1065.
Nishitani T, Ishikawa M, Kondoh T, et al. Burning plasma diagnostics, 2008, 988: 267-274.