An accurate and fast sampling method was developed on the modeling of a voxel phantom called Rad-HUMAN for radiation protection of MC-based radiation transport and simulation. The segmented organ voxels, which were assigned with three dimensional (3D) coordinates, were simplified through a two-step hybrid sampling algorithm. Firstly, certain voxels were sampled into a coordinate matrix by the nearest neighbor sampling. Secondly, the coordinate matrix was renewed using a weighted sampling. To compare visualization with the sampling, the resultant matrix was used to extract the contour of organs/tissues for constructing polygon-surface phantom. The feasibility and effectiveness of the sampling method was verified through the modeling of large organs (e.g. skeleton system) and application of transformation to MC computational geometries.
关键词
Keywords
SamplingMonte CarloVoxel3DRad-HUMAN
references
Wu Y C, Song G, Cao R F, et al. Chinese Phys C, 2008, 32: 77-182.
Zhao F, Xue Y, Chen Y, et al. Nucl Sci Tech, 2011, 22: 144-150.
Yang J B, Tuo X G, Li Z, et al. Nucl Sci Tech, 2010, 21: 221-226.
Liu Y, Xie T W, Liu Q, et al. Nucl Sci Tech, 2011, 22: 144-150.
Zhang Q H, Hui W H, Wang D, et al. Nucl Sci Tech, 2010, 21: 177-181.
Xu X G, Echerman K F. Handbook of Anatomical Models for Radiation Dosimetry, New York, CRC Press, 2009: 136-285.
Li Y, Lu L, Ding A P, et al. Fusion Eng Des, 2007, 82: 2861-2866.
Lu L, Lee Y K, Zhang J J, et al. Nucl Instrum Meth A, 2009, 605: 384-387.
Zeng Q, Lu L, Ding A, et al. Fusion Eng Des, 2006, 81: 2773-2778.
Li J, Huang S Q, Li G, et al. 2010 3rd International Congress on Image and Signal Processing, ISP2010, 2396-2400.
Ando M, Maksimenko A, Yuasa T, et al. Nucl Sci Tech, 2006, 17: 389-395.
Askri B, Trabelsi A, Baccari B, et al. Nucl Sci Tech, 2008, 19: 358-364.
Gou C J, Li X, Hou Q, et al. Nucl Sci Tech, 2011, 22: 349-352.
Wu Y C, FDS Team, Fusion Eng Des, 2009, 84: 1987-1992.
Kim C H, Jeong J H, Bolch W E, et al. Phys Med Biol, 2011, 56: 3137-3161.
Zeng Q, Lu L, Ding A, et al. Fusion Eng Des, 2006, 81: 2773-2778.
Zeng Q, Long P C, Zou J, et al. AIP Conf Proc, 2012, 1442: 265-266.
Lorensen W E and Cline H E. Comp Graph, ACM Siggraph’87, Conference Proceedings, 1987, 21: 163-169.
Xu X G, Chao T C, Bozkurt A. Health Phys, 2000, 78: 476-486.
Schimmerling W, Cucinotta F A, Wilson J W. Adv Space Res, 2003, 31: 27-34.
Hi’CT: a pixel sensor-based device for ion tomography
Parallel computing approach for efficient 3-D X-ray-simulated image reconstruction
Assessment of the induced radioactivity in the treatment room of the Heavy Ion Medical Machine in Wuwei using PHITS
Monte Carlo simulation for performance evaluation of detector model with a monolithic LaBr3(Ce) crystal and SiPM array for γ radiation imaging
Simulation of proton-neutron collisions in inverse kinematics and its possible application
Related Author
No data
Related Institution
Advanced Energy Science and Technology Guangdong Laboratory
School of Nuclear Science and Technology, University of Chinese Academy of Sciences
Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College
Institute of Modern Physics, Chinese Academy of Sciences