1.Physics Research Division, Pakistan Institute of Nuclear Science &Technology, P.O. Nilore, Islamabad, Pakistan
Scan for full text
M. AHMAD, W. AHMAD, M. U. RAJPUT, et al. Re-estimation of absolute gamma ray intensities of 56Mn using
The thermal neutron capture gamma ray facility at Pakistan Research Reactor (PARR-1) is being used for the re-estimation of various properties like capture cross-sections, resonance integral, absolute gamma intensities, etc. of different isotopes. The data for gamma ray transitions from the capture of thermal neutrons by ,55,Mn are not in good agreement specifically below 2 MeV. So there is a need to re-estimate its intensities with better accuracy. Analytical grade MnCl,2, powder and high purity Mn metal pieces were used in this study. Standard ,152,Eu and ,60,Co radioactive sources as well as thermal neutron capture γ-rays in chlorine were chosen for efficiency calibration. The ,k,0, standardization technique was applied for these measurements to eliminate systematic errors in efficiencies. Chlorine also acted as a comparator in ,k,0,- factor calculations. The results have been tabulated for the main gamma rays from,56,Mn in the low as well as in the medium energy regions. The absolute intensities are in good agreement with most of the reported values.
Absolute intensitiesPrompt gamma raysk0-standardizationManganese-56
Friendlander G, Kennedy J W, Macios E S, et al. Nucl. Radiochem, 3rd Edition, John Wiley & Sons, Inc., USA, 1981
Zaidi J H, Arif M, Fatima I, et al. J Radioanal Nucl Chem, 1999, 241: 123
Rajput M U, Ahmad M, Ahmad W. J Radioanal Nucl Chem, 2000, 243: 719
Dokhale P A, Csikia J, Olak L. Appl Radiat Isot, 2001, 54: 967
Ahmad W, Ahmad M, Rajput M U. J Neutron Res, 2003, 11: 145
Simonits A, De Corte F, Hoste J. J Radioanal Chem, 1975, 24: 31
Acharya R N, Sudarshan K, Nair A G, et al. J Radioanal Nucl Chem, 2001, 250: 303
Molnar G L, Belgya T, Dabolczi L, et al. J Radioanal Nucl Chem, 1997, 215: 111
Molnar G L, Revay Zs, Paul R L, et al. J Radioanal Nucl Chem, 1998, 234: 21
De Corte F, Simonits A, De Wispelaere A, et al. J Radioanal Nucl Chem, 1987, 113: 145
Matsue H, Yenozowa C. J Radioanal Nucl Chem, 2001, 249: 11
Knoll G F. Radiation Detection and Measurements, John Wiley & Sons. Inc. USA, 1979: 131
Kawade K, Ezuka M, Yamomats H, et al. Nucl Instr Meth, 1981, 190: 101
IAEA-TECDOC-619, X-ray and γ-ray standard for detector calibration, IAEA-1991
Sudarshan K, Nair A G, Acharya R N, et al. Nucl Instr Meth, 2001, A457: 180
Reedy R S, Frankle S C. At Data Nucl Data Tables, 2002, 80(1):
Ahamd M, Rajput M U, Ahmad W. The Nucleus, 1999, 36: 23
Satti M S. Prompt gamma-ray neutron activation analysis (PGNAA) of steel, M. Sc. Thesis, Univ. of Punjab, Lahore, PK, 2002
Jamil K, Ali S, Ahmad M, et al. The Nucleus, 1999, 36: 31
Sajjad M. Neutron flux estimation at thermal neutron capture gamma ray facility of Pakistan Research Reactor (PARR-I), M. Sc. Thesis, Univ. of Punjab, Lahore, PK, 2002
Rajput M U, Ahmad M, Ahmad W. J Radioanal Nucl Chem, 2002, 251: 457
Tahir M. Calibration of high purity germanium detector, M. Sc. Thesis, Univ. of Punjab, Lahore, PK, 2002
Paul R L, Lindstrom R M, Heald A. J Radioanal Nucl Chem, 1997, 215: 63
Matsue H, Yonezawa C. J Radioanal Nucl Chem, 2000, 245: 189
Mughabghab S F, Divadeeram M, Holden N E. Neurton Cross-sections, 1981, 1-A:
Vocke R D. Pure Appl Chem, 1999, 71: 1593
Rosman K J R, Taylor P D P. Pure Appl Chem, 1998, 70: 217
LANL Report LA-UR-01-4984 (2001)
Lone M A, Leavitt R A, Harrison D A. At Data Nucl Data Tables, 1981, 26: 511
Van Asseche P H M, Baader H A, Koch H R, et al. Nucl Phys, 1971, A160: 367
0
Views
16
Downloads
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution