Qian-Shun She, Yi QIAN, Jie KONG, et al. Design of fast adaptive readout system for wire scanners. [J]. Nuclear Science and Techniques 29(1):15(2018)
Qian-Shun She, Yi QIAN, Jie KONG, et al. Design of fast adaptive readout system for wire scanners. [J]. Nuclear Science and Techniques 29(1):15(2018) DOI: 10.1007/s41365-017-0343-3.
A new wide-range fast readout system capable of adaptive identification is designed for wire scanners, which are used to measure beam profiles and emittance. This system is capable of handling varying current signals with Gaussian distributions and current pulses up to 1000 counts/s, as well as an input current range of 1 nA–1 mA. When tested, the resolution was found to exceed 3.68% for full scale, the nonlinearity was found to be less than 0.11%, and the measurement sensibility was found to be less than 5 pA. We believe that the system will play a crucial role in improving the measurement accuracy of beam diagnosis and the efficiency of accelerator operation, as well as decreasing the time required for beam tuning. This system was applied to the beam diagnosis of an injector II prototype for an accelerator-driven subcritical system (ADS), and produced excellent measurement results. A description of the adaptive fast readout system for wire scanners is presented in this paper.
Wire scannerWeak-current measurementAdaptive identificationFront-end readout electronicsBeam diagnosis.
J. Sun, Y. Ruan, S. Xiao, et al. Design of beam profile and halo measurement system for high-intensity RFQ accelerator. High Power Laser Part. Beams 23, 190-194 (2011). (in Chinese) doi: 10.3788/HPLPB20112301.0190http://doi.org/10.3788/HPLPB20112301.0190
U. Hahn, N.V. Bargen, P. Castro, et al. Wire scanner system for FLASH at DESY. Nucl. Instrum. Meth. A 592, 189-196 (2008). doi: 10.1016/j.nima.2008.04.018http://doi.org/10.1016/j.nima.2008.04.018
A. La Rosa, M.A. Garella, F. Bourhaleb, et al. A pixel ionization chamber used as beam monitor at the Institute Curie-Centre de Protontherapie de Orsay (CPO). Nucl. Instrum. Meth. A 565, 833-840 (2006). doi: 10.1016/j.nima.2006.06.024http://doi.org/10.1016/j.nima.2006.06.024
Y.F. Sui, L. Wang, Y. Zhao, et al. BEPCⅡ wire scanner system. Chin. Phys. C 34, 1661-1664 (2010) doi: 10.1088/1674-1137/34/10/021http://doi.org/10.1088/1674-1137/34/10/021
D. Di Giovenale, L. Catani, L. Fröhlich, A read-out system for online monitoring of intensity and position of beam losses in electron linacs. Nucl. Instrum. Meth. A 665, 33-39 (2011). doi: 10.1016/j.nima.2011.11.038http://doi.org/10.1016/j.nima.2011.11.038
C.Y. Zhou, H. Su, R.S. Mao, et al. An accurate low current measurement circuit for heavy iron beam current monitor. Nucl. Instrum. Meth. B 280, 84-87 (2012). doi: 10.1016/j.nimb.2012.01.033http://doi.org/10.1016/j.nimb.2012.01.033
M. Ferrarini, V. Varoli, A. Favalli, et al. A wide dynamic range BF3 neutron monitor with front-end electronics based on a logarithmic amplifier. Nucl. Instrum. Meth. A 613, 272-276 (2010). doi: 10.1016/j.nima.2009.11.078http://doi.org/10.1016/j.nima.2009.11.078
C. R. Rose, W. Christensen, Lisa Day, et al. SNS WIRE SCANNER USER GUIDE, Los Alamos National Laboratory, 2002.11.
Y. Ruan, L. Han, H. Liu, et al. Design and simulation of a wire scanner for the CSNS linac. Chin. Phys. C 34, 1655-1660 (2010) doi: 10.1088/1674-1137/34/10/020http://doi.org/10.1088/1674-1137/34/10/020
Y. Liu, A. Aleksandrov, S. Assadi, et al. Laser wire beam profile monitor in the spallation neutron source(SNS) superconducting linac. Nucl. Instrum. Meth. A 612, 241-253 (2010). doi: 10.1016/j.nima.2009.10.061http://doi.org/10.1016/j.nima.2009.10.061
G. Schmidt, U. Hahn, M. Meschkat, et al. First results of the high resolution wire scanners for beam profile and absolute beam position measurement at the TTF. Nucl. Instrum. Meth. A 475, 545-548 (2001)
T. Yang, S. Fu, T. Xu, et al. Thermal analysis for wire scanners in the CSNS Linac. Nucl. Instrum. Meth. A 760, 10-18 (2014). doi: 10.1016/j.nima.2014.05.061http://doi.org/10.1016/j.nima.2014.05.061
A. E. Avetisyan, S. G. Arutunian, I. E. Vasiniuk, et al. Yerevan synchrotron injector electron beam transversal scan with vibrating wire scanner. Contemp. Phys. 46, 247-253 (2011). doi: 10.3103/S1068337211060016http://doi.org/10.3103/S1068337211060016
Z. Xu, R. Mao, L. Duan, et al. A new multi-strip ionization chamber used as online beam monitor for heavy ion therapy. Nucl. Instrum. Meth. A 729, 895-899 (2013). doi: 10.1016/j.nima.2013.08.069http://doi.org/10.1016/j.nima.2013.08.069
F. Yan, Z. Li, J. Tang. Preliminary physics design of China Accelerator Driven Sub-critical System main linac. High Power Laser Part. Beams 25, 1783-1787 (2013). (in Chinese) doi: 10.3788/HPLPB20132507.1783http://doi.org/10.3788/HPLPB20132507.1783
A. Bosco, M.T. Price, G.A. Blair, et al. A two-dimensional laser-wire scanner for electron accelerators. Nucl. Instrum. Meth. A 592, 162-170 (2008). doi: 10.1016/j.nima.2008.04.012http://doi.org/10.1016/j.nima.2008.04.012
0
Views
0
Downloads
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution