Introduction
Fast and reliable identification of γ-emitting radionuclides in public areas is crucial for nuclear safety. At customs and security checkpoints, such capabilities help prevent the smuggling of radioactive materials and protect national security. In nuclear power plant monitoring, they support the assessment of environmental and health impacts, enabling rapid decision-making during emergencies to minimize radiation risks. However, low-count detection is challenging due to background noise and heterogeneous media along the transport paths between the sources and detectors, which makes meaningful and timely detection difficult [1-3]. Classical methods used to identify radionuclides involve analyzing the full-energy peak structure in the spectra, such as the derivative peak searching method [4] and the second derivative peak identification method [5]. Novel detection methods have been proposed to mitigate the impact of noise and environmental backgrounds, including the stochastic resonance method [6], fuzzy logic radioisotopic pattern method [7], Poisson-statistics-based spectral decomposition algorithm [8], and convolutional neural networks (CNNs) [9], etc. Although these methods are reliable, they are limited by their exclusive reliance on the energy information of characteristic γ-rays. Moreover, the effectiveness of data analysis relies heavily on the quality of γ-ray spectral measurements, which requires acquisition of a substantial number of photons to obtain a spectrogram with reliable characteristics. Consequently, these methods cannot meet the urgent need for the real-time detection of radionuclides in public areas and emergency response scenarios.
In 2009, Candy et al. proposed a sequential Bayesian method for radionuclides [3]. This method leverages both the energy characteristic γ-rays and the temporal information of individual photons. The core concept is to process photons individually, to extract all available physical information, discard irrelevant signals from nontarget radionuclides, and retain only those associated with the targeted (threat) radionuclide(s) [10-13]. Candy later extended this approach by incorporating Compton scattering physics, resulting in improved performance over the original photoelectric-only processor [14]. However, studies on the performance and implementation details of this method remain limited. To address this, Xiang Qingpei developed a numerical experimental platform comprising a sequential Bayesian processor and an event sequence generator to validate this technique [15-18]. Using a ϕ3"×3" NaI(Tl) radiation monitoring system, Wen Siying demonstrated that this method provided faster identification and lower detection limits than traditional methods [19]. Wang Changlong enhanced this method by combining pulse characteristics with position transformation, improving the identification of moving targets [20, 21]. Li Zixin improved this by using full-spectrum energy information without relying on temporal information [22]. Wu Zeqian introduced a new model that excludes temporal information but requires extending the number of iterations for the decision-making function to enhance accuracy [23]. Gao Chao proposed a threshold selection method based on Monte Carlo simulations [24]. Li Xiaozhe replaced the background interarrival time distribution assumption from Gaussian to uniform distribution and on this basis, proposed a rapid nuclide recognition system [25-27]. Fang Xinchao further optimized the algorithm by integrating dynamic environmental background parameters and conducting repeated tests to adapt to changes in the environmental background [28]. However, these methods require prior knowledge of sample-specific parameters-such as the time interval variance- which are typically unknown during real-time measurements. Moreover, limited research exists on distinguishing between Compton plateaus, background characteristic γ-rays, and radionuclide-specific characteristic γ-rays. These challenges continue to hinder the practical implementation and reliability of current radionuclide identification techniques.
When instruments are deployed in public spaces, background radiation remains relatively constant regardless of the presence of radionuclides [25]. However, when radionuclides are present, both the energy variance and time intervals between photon events decrease relative to background-only conditions. Furthermore, the distribution characteristics of energy and time within regions of interest (ROIs) differ depending on the type of γ-rays. Leveraging these observations, we propose a theoretically optimized sequential Bayesian approach for rapid identification of γ-emitting radionuclides. Based on the statistical differences between background and radionuclide emissions observed in event mode sequence (EMS), two distinct probabilistic models were developed to characterize their respective behaviors. The posterior probabilities were calculated using Bayes’ theorem with non-informative priors and Bayesian factors, while prior probabilities were dynamically updated through sequential detection. By analyzing the relationship between energy- and time-based decision functions and their respective thresholds, the method can effectively differentiate Compton plateaus, background characteristic γ-rays, and radionuclide-specific characteristic γ-rays, etc. Finally, the joint decision function for multiple characteristic γ-rays of the targeted radionuclide is compared with a preset threshold for detecting radionuclides. This model was constructed and validated experimentally using a LaBr3(Ce) detector with typical radionuclides (137Cs, 60Co, and 133Ba) under different background radiation conditions.
Method of sequential Bayesian approach
The monoenergetic decomposition concept [3] was proposed to leverage the EMS information. Suppose that the sequence of photons emitted by a radionuclide is a set of photons emitted by several separate monoenergetic sources. More precisely, we define _2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M001.png)
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M002.png)
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M003.png)
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M004.png)
The deviations observed during the comparison between the measured spectrum and expected stable background signal may indicate potential instances of radionuclides. Consequently, a hypothesis test was applied to identify the radionuclides through sequential detection based on the two hypotheses.
For hypotheses H0 and H1, the conditional probability density function _2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M005.png)
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M006.png)
The conditional probability density function _2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M007.png)
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M008.png)
A posterior probability is deduced analytically from a noninformative a priori probability. The prior probability density functions (PDFs) for parameters σ2 and τ are described as follows:_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M009.png)
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M010.png)
Bayesian factors are defined as the ratio of the posterior odds to the prior odds [30] and are described as follows:_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M011.png)
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M012.png)
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M013.png)
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M014.png)
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M015.png)
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M016.png)
By combining the decision functions for _2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M017.png)
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M018.png)
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M019.png)
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M020.png)
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M021.png)
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-M022.png)
Experimental designs
Experimental conditions and equipment
A proof-of-concept experiment was developed to assess the feasibility of the sequential Bayesian processor and its ability to detect and identify targeted radionuclides. This experiment was conducted in the low-background radiation laboratory at the Nuclear and Radiation Safety Center’s Changyang Base (NRSC) and Natural Background Radiation Laboratory at the National Institute of Metrology’s Changping Base (NIM). The radiation levels in the low background radiation laboratory (
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-F001.jpg)
| Type | Activity | Manuf ID | γ-rays energy (keV) | γ-rays branch (%) | γ-rays FWHM (keV) |
|---|---|---|---|---|---|
| 137Cs | 8.92×103 Bq@19/3/23 | 341NIM | 661.62 | 85.01 | 18.36 |
| NIM | |||||
| 60Co | 3.50×104 Bq@17/3/23 | 191101 | 1173.23 | 99.85 | 23.87 |
| NIM | 1332.50 | 99.98 | 26.09 | ||
| 133Ba | 1.34×105 Bq@22/3/23 | 0609-9 | 79.6+81.0a | 2.63+33.31 | 7.31 |
| 276.40 | 7.13 | 11.87 | |||
| 302.85 | 18.31 | 12.64 | |||
| 356.01 | 62.05 | 13.57 | |||
| NIM | 383.85 | 8.94 | 13.97 | ||
| LaBr3(Ce) |
— | SAINT-GOBAIN | — | — | — |
| ADC | — | 10870017 | — | — | — |
| Jiechuang Nuclear Instrument (Beijing) Technology Co., Ltd. |
| Distance (cm) | Source dose rate contribution (μGy·h-1) | |||||
|---|---|---|---|---|---|---|
| 137Cs | 60Co | 133Ba | ||||
| Lowa | Naturalb | Lowa | Naturalb | Lowa | Naturalb | |
| 7 | 0.13 | 0.13 | 2.07 | 1.88 | 1.82 | 1.70 |
| 12 | 4.5×10-2 | 4.4×10-2 | 0.72 | 0.66 | 0.63 | 0.59 |
| 17 | 2.3×10-2 | 2.2×10-2 | 0.36 | 0.33 | 0.32 | 0.30 |
| 22 | 1.4×10-2 | 1.3×10-2 | 0.22 | 0.19 | 0.19 | 0.18 |
| 27 | 9.1×10-3 | 8.9×10-3 | 0.14 | 0.13 | 0.13 | 0.12 |
| 32 | 6.5×10-3 | 6.4×10-3 | 0.10 | 9.0×10-2 | 9.1×10-2 | 8.5×10-2 |
| 37 | 4.9×10-3 | 4.8×10-3 | 7.7×10-2 | 6.8×10-2 | 6.8×10-2 | 6.4×10-2 |
| 42 | — | — | 6.0×10-2 | 5.3×10-2 | 5.3×10-2 | 4.9×10-2 |
| 47 | — | — | 4.8×10-2 | 4.2×10-2 | 4.2×10-2 | 4.0×10-2 |
| 52 | — | — | 3.9×10-2 | 3.4×10-2 | 3.4×10-2 | 3.2×10-2 |
Parameter preset
A sequential Bayesian processor was embedded within a radionuclide library comprising 22 radionuclides. The parameters of radionuclides for 137Cs, 60Co, and 133Ba are listed in Table 1. The ROIs were set to full width at tenth maximum (FWTM) interval, where the coverage factor was k=2.146. The background count rates within each ROIs were determined using a continuous 12-hour measurement of the environmental background.
Because of the unbiasedness of the prior probability, the initial value of the prior probability was set to 0.5. For any feasible radionuclide identification method, the following performance criteria are generally required: when no radionuclide is present, the false alarm rate is not significant, and a high detection performance is not required. However, when a radionuclide is present, the miss rate, detection time, and sample size should be minimized. Therefore, in this study, the parameters are set to α=0.2 and β=0.2.
Results and discussions
Background experiment
Results of pulse-height spectra and EMS progress
Using a fast radionuclide identification method, the typical radionuclides (137Cs, 60Co, and 133Ba) were detected under conditions of low and natural background radiation. The pulse-height spectra (PHS) and EMS detected under low and natural background radiation are shown in Fig. 2(a)-(d). In the spectra and EMS, we first observe a low-energy peak centered at approximately 35.5 keV, which is an intrinsic characteristic γ-rays in LaBr3(Ce). This is attributed to the sum of 95.6% of the 31.83 keV Kα X-ray response and 90% of the 5.6 keV Auger electron response in the EC decay process, by referring to the theoretical calculation [33]. Subsequently, we observe a β continuum with an end point of 263 keV mixed with the Compton continua, primarily from the 788.7 and 1435.8 keV of 138La and the 1460.8 keV of 40K. With increasing energy, the 788.7 keV bump is shown to extend to higher energies and end at approximately 1 MeV. This is because of the coincidence of the 788.7 keV γ with the β- continuum [33]. Finally, we observed the 1436 keV gamma, but it was displaced to a higher energy by approximately 37 keV to 1473 keV owing to the coincident capture of X-rays, resulting in Ba K-level filling following K-electron capture. Similarly, the hump near 1441 keV on the low-energy side of the 1473 line is a result of the 1436 keV gamma plus 5 keV owing to the 1436 keV gamma plus 5 keV because of the coincident capture of X-rays when the Ba L-level fills following L-electron capture [34]. A comparison of the PHS and EMS between low- and natural-background radiation revealed a higher abundance of low-energy photons in the natural background. Furthermore, the significant presence of 1460 keV γ-rays from 40K in the natural background radiation contributed to the overlap of the peaks, making it difficult to distinguish between the 1436 keV and 1473 keV peaks.
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-F002.jpg)
According to Eqs. (13)–(17), the sequential Bayesian method was used to detect background characteristic γ-rays. As shown in Fig. 3(a)–(c), although both the energy and time decision functions exhibit oscillations in the early stages of identification, however, they do not affect their overall trends or final identification result. Under low background radiation, a 35.5 keV γ-ray could be identified within 0.764 s, whereas under natural background radiation, it could be detected within 0.572 s. The higher presence of low-energy photons in natural background radiation makes it more challenging to make evaluations based on the energy decision function than on the time decision function, as illustrated in Fig. 3(a). The 1473 keV γ-ray can be identified under low background radiation with a detection time of 6.83 s, under natural background radiation identification encounters difficulties owing to interference from the 1460 keV γ-ray. Nevertheless, by combining 1436 keV and 1473 keV γ-rays into a single ROI, rapid identification becomes possible with a detection time of 2.77 s. Additionally, under low background radiation, the identification speed is slower because of the non-Gaussian distribution, as illustrated in Fig. 2(a), with a detection time of 13.67 s.
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-F003.jpg)
As each photon is processed, the decision function is sequentially updated until one of the thresholds (target/non-target) is crossed, indicating a threat or non-threat. As shown in Fig. 4(a)–(c), the decision function gradually increases as events are processed until it exceeds the high threshold, indicating the absence of radionuclides at
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-F004.jpg)
This identification was achieved using the energy and time interval information of the ROI. However, by disregarding information from individual ROIs and considering only the temporal characteristics of the full spectrum, a hypothesis can be formulated [35]. By computing the posterior probability using only a time-sequential Bayesian approach for decision-making based on the full spectrum, a faster identification speed was achieved, as shown in Fig. 4(d). The detection time did not exceed 5 s. Therefore, for background discrimination, the sequential Bayesian decision-making method based on the time-sequenced full spectrum was more effective. This method be used initially to determine the presence of background.
Detection performance experiments
To evaluate the detection performance of the proposed method, a series of experiments were conducted under both low and natural background radiation without radionuclides, with 20 repeated detection experiments for each condition. The analysis was based on the decision functions for 137Cs, 60Co, 133Ba and a time-sequenced full spectrum. Table 3 presents the average detection time, average number of γ-rays per ROI, and false-alarm rate for different radionuclides.
| Radionuclide | 137Cs | 60Co | 133Ba | Time-sequenced full spectrum | ||||
|---|---|---|---|---|---|---|---|---|
| Low | Natural | Low | Natural | Low | Natural | Low | Natural | |
| Average detection time (s) | 53.43±53.12 | 30.16±26.06 | 246.43±178.63 | 89.87±93.68 | 72.0±59.62 | 16.51±14.77 | 5.29±6.22 | 4.48±4.69 |
| Average number of γ-rays per ROI | 25±30 | 29±30 | 73±55 | 48±57 | 49±43 | 64±61 | 310±366a | 659±744a |
| t value | -3.30 | 1.369 | -0.942 | -1.88 | ||||
| P value | 0.743 | 0.179 | 0.352 | 0.071 | ||||
| False alarm rate (%) | 0 | 5 | 0 | 0 | 0 | 0 | 15 | 30 |
Based on the time-sequenced full-spectrum radionuclide detection method [35], the false alarm rates under low and natural background radiation were 15% and 30%, respectively, which indicates the probability of misidentifying non-source events as source events. The false identification rate of 137Cs under natural background radiation was 5%. False-alarm events often result in increased detection times and larger sample sizes. These false alarm events were primarily concentrated in the early stages of detection, as shown in Fig. 5(a). During the initial phase, the limited sample size led to significant statistical fluctuations in the data, which amplified the influence of random errors and resulted in false-alarm events. In particular, as shown in Fig. 5(b), most energy samples fall near the center of the ROI, and the random fluctuations in the timing of radiation samples cause the decision function to mistakenly indicate the presence of a radionuclide. The impact of these random errors diminished as the sample size gradually increased, reducing the occurrence of false alarms and ultimately achieving accurate background identification.
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-F005.jpg)
Using an independent samples two-sided t-test to compare the number of γ-rays for background identification under various background radiation, the results in Table 3 indicated that the difference between the two conditions was not statistically significant (P>0.05). This suggests that, statistically, the required number of γ-rays for background identification is similar under a natural background and low background radiation.
This finding explains the relatively short time required for background identification under natural background irradiation. This is because regardless of the specific radionuclide, the number of γ-ray detections required for background discrimination remains consistent. However, the count rate under natural background radiation exceeded that under low-background conditions. Consequently, background identification was accomplished more rapidly using natural background radiation.
Radionuclide detection experiment
Results of pulse-height spectra and EMS progress
137Cs was positioned 37 cm in front of the LaBr3(Ce) detector with a source dose rate contribution of 4.9 nGy/h. 60Co and 133Ba were placed 52 cm from the LaBr3(Ce) detector with source dose-rate contributions of 3.9×10-2 μGy/h and 3.4×10-2 μGy/h, respectively, under low background radiation. However, under natural background radiation, the source dose rate contributions were 4.8 nGy/h for 137Cs, 3.4×10-2 μGy/h for 60Co, and 3.2×10-2 μGy/h for 133Ba. The decision functions are shown in Fig. 6.
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-F006.jpg)
Radionuclide identification was conducted under known background conditions, and the initial probability was adjusted accordingly. As each photon is discriminated and processed, the decision function is sequentially updated until one of the thresholds is crossed, signifying non-threat (upper threshold) or threat (lower threshold). Based on the time-sequenced full spectrum radionuclides detection method [35], the detection times for the presence of radionuclides are 9.99 s and 1.91 s for 137Cs, 2.49 s and 1.29 s for 60Co, and 0.43 s and 0.29 s for 133Ba, under low and natural background radiation, respectively. The corresponding numbers of γ rays were 640 and 370 for 137Cs, 183 and 265 for 60Co, and 67 and 94 for 133Ba.
The identification times for 137Cs, 60Co and 133Ba under low background radiation are 5.01 s, 9.49 s, and 3.43 s, with corresponding numbers of γ-rays per ROI of 15, 16, and 30, respectively. Under natural background radiation, the identification times are 8.19 s, 12.33 s, and 5.50 s, with corresponding numbers of γ-rays per ROI of 22, 23, and 70, respectively. Figure 7 illustrates the pulse-height spectra at the time of detection. At the moment of detection, only a small number of counts had accumulated in the ROI for 137Cs, 60Co, and 133Ba, resulting in an indistinct or unformed peak.
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-F007.jpg)
Using the time-sequenced full spectrum method to determine the presence or absence of a nuclide is faster than using the ROI, except for 137Cs under low background radiation. Therefore, first use the sequential Bayesian method based on a time-sequenced full spectrum to determine the presence of radionuclides and then use ROI-based analysis to identify the specific radionuclides.
When exposed to a 60Co source, decision functions for ROIs at various energy levels were calculated. The analysis revealed that the ROI at 35.5 keV was identified as a background characteristic γ-ray at 0.497 s and 0.683 s, the ROI at 661.62 keV was recognized as a Compton plateau at 28.0 s and 40.59 s, and the ROI at 1332.5 keV was classified as a characteristic γ-ray at 7.41 s and 8.68 s under low and natural background radiation, respectively, as shown in Fig. 8. These results demonstrate that simultaneously applying the time interval and energy decision functions effectively discriminates between Compton plateaus, background characteristic γ-rays, and radionuclide-specific characteristic γ-rays.
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-F008.jpg)
Detection performance experiments
Experiments were conducted by varying the distance between the source and detector to evaluate the performance of the proposed method. The radionuclides were placed at different distances in front of the LaBr3(Ce) detector, and the measurements were repeated 20 times. The average detection time was calculated and plotted for each experimental group, as shown in Fig. 9. All measurements successfully detected the corresponding radionuclides, yielding a miss rate of 0% for the background detection. Overall, the miss rate remained below 0.01%.
_2026_02/1001-8042-2026-02-27/alternativeImage/1001-8042-2026-02-27-F009.jpg)
When the detection distance is set to 7 cm (source dose rate contribution: 0.13 μGy/h, refer to Table 2), the 137Cs detection time is 0.36 s and 0.49 s under low and natural background radiation, respectively. The distance increased along with the detection time. When the distance reaches 32 cm, the average detection time increases to 7.9 s and 8.5 s. For 60Co, the average detection time is within 2.0 s when the detection distance is within 22 cm. At a distance of 47 cm, the average detection time is 8.1 s and 9.8 s under low and natural background radiation, respectively. For 133Ba, as the distance increased from 2 to 52 cm, the detection time under low background conditions increased from 0.062 s to 4.05 s, whereas under natural background radiation, it increased from 0.058 s to 5.99 s, meeting the requirements for rapid identification.
The relationship between the source dose rate contribution and detection time, as depicted in Fig. 9(a), demonstrates a power-law relationship, meaning detection time decreases as dose rate increases. The detection times remained largely consistent across different background radiation levels, indicating that the radionuclide identification performance was affected to a lesser extent by variations in the background radiation. The relationship between net count rate and detection time followed the same pattern, as shown in Fig. 9(b). However, under equivalent net count rate conditions, the detection times followed the order 133Ba > 60Co > 137Cs. Similarly, at the same source dose-rate contribution, 60Co exhibited longer detection times than 133Ba and 137Cs. This disparity arises because 60Co emits two high-energy characteristic γ-rays, whereas 133Ba emits multiple γ-rays. Consequently, 133Ba achieved a higher net count rate than 60Co for the same source dose-rate contribution.
Conclusions and prospects
This study proposes a fast identification approach for γ-emitting radionuclides in public areas based on a sequential Bayesian approach. This method assumes that the energy variance and time intervals decrease when radionuclides are present compared with the background. Two distinct probability models were developed: one for the background radiation and the other for the target radionuclide. The posterior probability is obtained using noninformative prior and a Bayesian factor based on the different characteristics of the energy and time interval distributions. The target radionuclide is identified by integrating the decision functions of multiple characteristic γ-rays.
This approach leverages the differing energy and time distributions of γ-rays within regions of interest (ROIs). By analyzing the relationship between the energy and time decision functions and their corresponding thresholds, the method effectively distinguishes between Compton plateaus, background characteristic γ-rays, and radionuclide-specific characteristic γ-rays—a capability rarely reported in other sequential Bayesian approaches. In addition, unlike traditional methods, which require preset values for the mean and variance of the time interval when a radionuclide is present, this approach requires only a preset time range that is smaller than the background time interval. This innovation helps avoid the influence of unpredictable factors such as source activity, thereby enhancing its applicability across different conditions.
A particular realization of the process was successfully developed and applied to proof-of-concept experimental data demonstrating its overall feasibility under low and natural background radiation. This approach can identify 137Cs in 7.9 s and 8.5 s (source dose rate contribution: approximately 6.5 × 10-3 μGy/h), 60Co in 8.1 s and 9.8 s (approximately 4.8 × 10-2μGy/h), and 133Ba in 4.05 s and 5.99 s (approximately 3.4 × 10-2μGy/h,) under low and natural background radiation, respectively, with a miss rate of less than 0.01%. This demonstrates the effectiveness of the proposed method for the rapid identification of radionuclides, even at low activity levels, which can help establish an accurate and timely radioactive material detection system as an additional nuclear safety application option, particularly for public safety.
To fully explore the applicability of this method across various scenarios, experiments were conducted under both low background radiation simulation conditions in which the detector is shielded in systems such as item monitoring [36], and natural background radiation simulation conditions in which the detector is directly exposed to the environment. Without radionuclides, background detection occurs more quickly under natural background radiation than under low background radiation because, although the number of particles required is the same, a higher dose rate accelerates the process. In the presence of radionuclides, the detection times remained largely consistent across the different background radiation levels.
However, this approach requires prolonged evaluation time for background discrimination. Therefore, we recommended first using the sequential Bayesian method based on a time-sequenced full spectrum to determine the presence of radionuclides [35] and then use ROI-based analysis to identify the specific radionuclides.
Future work will focus on further optimizing the algorithm. To enhance its applicability in complex environments, research efforts should aim at achieving rapid detection and identification of radionuclide types in mixed compositions, particularly under challenging background conditions and dynamic source movements.
Evaluation of key detector parameters for isotope identification
.Physics-based detection of radioactive contraband: a sequential Bayesian approach
. IEEE T. Nucl. Sci. 56, 3694–3711 2009). https://doi.org/10.1109/TNS.2009.2034374Development of measurement and analysis software for multi-channel gamma-ray spectrometer
. Master’s dissertation,A method for automatic identification of peaks in the presence of background and its application to spectrum analysis
. Nucl. Instrum. Methods. 50, 309–320 1967). https://doi.org/10.1016/0029-554X(67)90058-4Methods and experiments for weak nuclear signal detection and nuclide identification
. Dissertation,Assessment of fuzzy logic radioisotopic pattern identifier on gamma-ray signals with application to security
. Int. J. Monit. Surveillance Technol. Res. 2, 1–21 2014). https://doi.org/10.4018/ijmstr.2014010101Bayesian spectral deconvolution based on poisson distribution: Bayesian measurement and virtual measurement analytics (VMA)
. J. Phys. Soc. Jpn. 88,Automatic and real-time identification of radionuclides in Gamma-Ray spectra: a new method based on convolutional neural network trained with synthetic data set
. IEEE T. Nucl. Sci. 67, 644-6532020). https://doi.org/10.1109/TNS.2020.2969703Radioactive contraband detection: A Bayesian approach
. OCEANS 2009. 1-10 2009). https://doi.org/10.23919/OCEANS.2009.5422451Bayesian processing for the detection of radioactive contraband from uncertain measurements
. inPhysics-based detection of radioactive contraband: a sequential Bayesian approach
. IEEE T. Nucl. Sci. 56, 3694–37112009). https://doi.org/10.1109/TNS.2009.2034374Threat detection of radioactive contraband incorporating compton scattering physics: a model-Based processing approach
. IEEE T. Nucl. Sci. 58, 214–230 2011). https://doi.org/10.1109/TNS.2010.2090361Off-line experiments on radionuclide detection based on the sequential Bayesian approach
. Nucl. Instrum. Meth. Phys. Res. Sect. 729, 212–2192013). https://doi.org/10.1016/j.nima.2013.07.046Numerical study on the sequential Bayesian approach for radioactive materials detection
. Nucl. Instrum. Meth. Phys. Res. Sect. 697, 107–113 2013). https://doi.org/10.1016/j.nima.2012.09.031On-line experiments on rapid detection of radionuclides based on sequential Bayesian analysis
. J. Radioanal. Nucl. Chem. 306, 57–70 2015). https://doi.org/10.1007/s10967-015-4072-yResearch on nuclide identification algorithm based on sequential Bayesian method
, Dissertation,The study on nuclide identification algorithm based on sequential Bayesian analysis
. Nucl. Eng. Dete. Tech. 36, 179–183 2016). https://doi.org/10.3969/j.issn.0258-0934.2016.02.015Rapid detection of weak radionuclide in moving target
. Inf. Tec. Net. Sec. 37, 137–139 2018). https://doi.org/10.19358/j.issn.2096-5133.2018.03.033The study of radioactive nuclide identification method based on random pulse information and Bayesian classifier
, Master dissertation,Fast nuclide identification based on energy weight graph
. Nucl. Electron. Detect. Technol. 39, 501–507 2019). https://doi.org/10.3969/j.issn.0258-0934.2019.04.022Design of radionuclides identification algorithm based on sequence Bayesian method
.Study on sequential Bayesian radionuclide identification approach: Threshold and detection capability
.Fast nuclide identification based on a sequential Bayesian method
. Nucl. Sci. Tech. 33, 29 2022). https://doi.org/10.1007/s41365-021-00982-zResearch of nuclide identification method based on background comparison method
. Appl. Radiat. Isot. 192,Research and design of a rapid nuclide recognition system
. J. Instrum. 17,Study on the sequential Bayesian approach for a CsI(Tl)-based radioactive material detection system
. Nucl. Instrum Meth. Phys. Res. A 1038,Benchmark of the nonparametric Bayesian deconvolution method implemented in the SINBAD code for X/γ rays spectra processing
. Nucl. Instrum. Meth. Phys. Res. A 836, 91–97 2016). https://doi.org/10.1016/j.nima.2016.08.025Model-based signal processing
. J. Acoustical Soc. Am. 119, 2553 2006). https://doi.org/10.1121/1.2184129Air kerma rate constants for gamma emitters used most often in practice
. Radiat. Prot. Dosim. 115, 247–250 2005). https://doi.org/10.1093/rpd/nci131Air kerma rate constants for nuclides important to gamma ray dosimetry and practical application
. Med. Phys. 2012). https://doi.org/10.5772/39170Study of 138La radioactive decays using LaBr3 scintillators
. Nucl. Instrum. Meth. Phys. Res. A 683, 46–52 2012). https://doi.org/10.1016/j.nima.2012.04.066Intrinsic background radiation of LaBr3(Ce) detector via coincidence measurements and simulations
. Nucl. Sci. Tech. 31, 99 2020). https://doi.org/10.1007/s41365-020-00812-8Research of fast detection method for radionuclides based on sequential Bayesian approach
. Nuclear Techniques (in Chinese) 48,Belt-conveyor type non-destructive radioactive caesium contamination monitoring machine
. Radioisotopes. 67, 67–73 2018). https://doi.org/10.3769/radioisotopes.67.67The authors declare that they have no competing interests.

