logo

Excitation curve calibration for the SSRF booster magnets and applications in the commissioning

SYNCHROTRON TECHNOLOGY AND APPLICATIONS

Excitation curve calibration for the SSRF booster magnets and applications in the commissioning

HOU Jie
SUN Xiaoying
CHEN Guangling
ZHOU Xuemei
LI Haohu
LIU Guimin
Nuclear Science and TechniquesVol.19, No.4pp.204-208Published in print 20 Aug 2008
43400

The Shanghai Synchrotron Radiation Facility (SSRF) is a low emittance third-generation synchrotron radiation light source under commissioning. The excitation curve calibration for the booster magnets is important to provide the magnet current configurations as reference. Calibration studies give the polynomial coefficients of each type of magnets and provide the magnet current configurations under different beam energies as beam is ramped at speed of 2 Hz. The applications of calibration in booster commissioning which show the accuracy of the magnetic excitation curve calibration are also discussed.

BoosterMagnetCalibrationCommissioning
References
[1] Xu H J, Zhao Z T. Nucl Sci Tech, 2008, 19: 1-6.
[2]

SSRF design report, Chapter 3

, 2005, 96-103.
Baidu ScholarGoogle Scholar
[3] SSRF technique specifications, SSRF-BSMG-SP-50, -51, -52/2005, 2005.
[4] Bozoki E. IEEE Transactions on Nuclear Science, 1983, NS-30: 2219-2221.
[5] Portmann G J, Corbett J, Terebilo A. Middle layer software manual for accelerator control, August, 2006.