logo

Major parameter measurement of high-brightness injector in Hefei Light Source

SYNCHROTRON SCIENCE AND TECHNOLOGY

Major parameter measurement of high-brightness injector in Hefei Light Source

WANG Xiaohui
HE Zhigang
SUN Baogen
JIA Qika
Nuclear Science and TechniquesVol.22, No.4pp.200-204Published in print 20 Aug 2011
32400

A photocathode radio frequency gun, which is an S-band normal conducting 1.6 copper cell cavity with water cooling system, was installed in Hefei Light Source. In order to know its characteristics and get it into normal operation, continuous conditioning was conducted in the last few months. Beam charge and dark current charge were measured using integrating current transformer. The beam transverse size was determined as 1.63 mm in minimum using YAG screen and GigE Vision camera. Using multi-slits technique, the transverse emittance was measured and normalized at 1.95 mm·mrad with beam charge of 240 pC. The results provide a way to optimize the facility.

Photocathode RF gunTransverse emittanceBeam chargeSolenoid
References
[1] Gibson D J, Anderson S G, Barty C P J, et al. Phys Plasmas, 2004, 11: 2857-2864.
[2] Neumann J, Fiorito R, Freund H, et al.

Generation of Terahertz Radiation by Modulating the Electron Beam at the Cathode

. Proceedings of the 2004 FEL Conference, Trieste, Italy, 2004, 9, 586-589.
Baidu ScholarGoogle Scholar
[3] Wang X H, Sun B G, Lu P, et al.

Design of Beam Measurement System for High Brightness Injector in HLS

. Proceedings of PAC 2009, Vancouver, Canada, 2009, 5, 4090-4092.
Baidu ScholarGoogle Scholar
[4] Unser K B.

Design and Preliminary Tests of a Beam Intensity Monitor for LEP

. Proceedings of the 1989 IEEE Accelerator Conference, Chicago, USA, 1989, 1(3): 71-73.
Baidu ScholarGoogle Scholar
[5] Otevrel M, Asova G, Bähr J W, et al.

Conditioning of A New Gun at PITZ Equipped with An Upgraded RF Measurement System

. Proceedings of the 2010 FEL conference, Malmö, Sweden, 2010, 8, 398-401.
Baidu ScholarGoogle Scholar
[6] Tang L L, Sun B G, Wang J G, et al.

Application of the Gige Vision Digital Camera for Beam Diagnostics in HLS

. Proceedings of IPAC 2010, Kyoto, Japan, 2010.5, 1041-1043.
Baidu ScholarGoogle Scholar
[7] Flöttmann K, http://www.desy.de/~mpyflo/(September 8, 2010).
[8] Anderson S G, Rosenzweig J B, Lesage G P, et al.

Emittance Measurements of the Space Charge Dominated Thomson Source Photoinjector

. Proceedings of PAC 2001, Chicago, USA, 2001.6, 2260-2262.
Baidu ScholarGoogle Scholar
[9] Rosenzweig J, Travish G. Nucl Instrum Meth,1994, A341: 379-385.