logo

Study of time-domain digital pulse shaping algorithms for nuclear signals

LOW ENERGY ACCELERATOR AND RADIATION APPLICATIONS

Study of time-domain digital pulse shaping algorithms for nuclear signals

ZHOU Jianbin
ZHOU Wei
LEI Jiarong
TUO Xianguo
ZHU Xing
LIU Yi
Nuclear Science and TechniquesVol.23, No.3pp.150-155Published in print 20 Jun 2012
37503

With the development on high-speed integrated circuit, fast high resolution sampling ADC and digital signal processors are replacing analog shaping amplifier circuit. This paper firstly presents the numerical analysis and simulation on R-C shaping circuit model and C-R shaping circuit model. Mathematic models are established based on 1st order digital differential method and Kirchhoff Current Law in time domain, and a simulation and error evaluation experiment on an ideal digital signal are carried out with Excel VBA. A digital shaping test for a semiconductor X-ray detector in real time is also presented. Then a numerical analysis for Sallen-Key (S-K) low-pass filter circuit model is implemented based on the analysis of digital R-C and digital C-R shaping methods. By applying the 2nd order non-homogeneous differential equation, the authors implement a digital Gaussian filter model for a standard exponential-decaying signal and a nuclear pulse signal. Finally, computer simulations and experimental tests are carried out and the results show the possibility of the digital pulse processing algorithms.

R-C shapingC-R shapingNuclear pulseDigital S-K filterDigital Gaussian filter
References
[1] Wang J J, Fan T M, Qian Y G. Nuclear electronics. Beijing: Atomic Energy Press, 1983 (in Chinese).
[2] Wang Z Y, Lou B Q, Zhu J J, et al. Principle of Nuclear Electronics. Beijing: Atomic Energy Press, 1989 (in Chinese).
[3] Hu X J. Circuit Analysis. Beijing: Higher Education Press, 2001 (in Chinese).
[4] Wang B X. Signal and System. Harbin: Harbin Institute of Technology Press, 2003 (in Chinese).
[5] Jordanov V T, Knoll G F. Nucl Instrum Methods Phys Res Sec A, 1994, 345: 337-345.
[6] Jordanov V T, Knoll G F, Huber A C. Nucl Instrum Methods Phys Res Sec A, 1994, 353: 261-264.
[7] Jordanov V T, Knoll G F. IEEE Transact Nucl sci, 1995, 42: 683-687.
[8] Jordanov V T, Pantazis J A, Huber A C. Nucl Instrum Methods Phys Res Sec A, 1996, 380: 353-357.
[9] Jordanov V T. Nucl Instrum Methods Phys Res Sec A, 2003, 505: 347-351.
[10] Chen S G, Ji S Y, Liu W S, et al. Acta Phys Sinica, 2008, 57: 2882-2887 (in Chinese).
[11] Chen S G, Ji S Y, Liu W S, et al. Acta Phys Sinica, 2009, 58: 3041-3046 (in Chinese).
[12] Li D C, Yang L, Tian Y, et al. Nucl Electron Detection Technol, 2008, 28: 563-566 (in Chinese).
[13] Li D C, Yang L, Tian Y, et al. J Lanzhou University (Nat Sci), 2007, 43: 110-113 (in Chinese).
[14] Zhou J B, Zhou W, Fang F, et al. 2011 Proceedings of the 10th International Conference on Electronic Measurement & Instruments, 2011, 4: 163-165.