logo

The measurement of electron beam transverse sizes by synchrotron radiation interferometry for HLS II

SYNCHROTRON SCIENCE AND TECHNOLOGY

The measurement of electron beam transverse sizes by synchrotron radiation interferometry for HLS II

TANG Leilei
SUN Baogen
LU Ping
WANG Jigang
XIAO Yunyun
Nuclear Science and TechniquesVol.23, No.4pp.193-198Published in print 20 Aug 2012
34201

In order to improve accuracy of electron beam transverse sizes measurement, the vertical and horizontal synchrotron radiation light interferometers have been designed to measure beam transverse sizes for the upgrade project of Hefei Light Source (HLS II). In this paper, the light intensity distributions of the interferogram are descussed, and parameters of the interferometers are optimized. The interferograms are simulated under MATLAB. Taking integrations of two-dimensional interferogram intensity, normalized one-dimensional interference intensities distribution of the vertical and horizontal interferogram are obtained. The two curves are fitted to compare the beam transverse sizes with the designed sizes, and this verifies the feasibility of this method. Finally, several factors that affect the beam sizes measurement are discussed.

Beam transverse sizesSynchrotron radiation interferometerInterferogramSimulation
References
[1] Sun B G, Zheng P, Lu P, et al.

Development of new beam profile and emittance measurement system for HLS

. High Energy Phys Nucl Phys, 2006, 8, 30: 792-796.
Baidu ScholarGoogle Scholar
[2] Mitsuhashi T.

Spatial coherency of the synchrotron radiation at the visible light region and its application for the electron beam profile measurement

. Proceedings of PAC 1997, Vancouver, BC, Canada, 1997, 5: 766-768.
Baidu ScholarGoogle Scholar
[3] Chen J, Ye K R, Leng Y B.

Developmemnt of Shanghai synchrotron radiation racility synchrotron radiation interferometer

. High Power Laser Particle Beams, 2011, 23: 179-184.
Baidu ScholarGoogle Scholar
[4] Mitsuhashi T.

Beam profile and size measurement by SR interferometer

. In beam measurement, proceedings of joint US-CERN-Japan-Russia School on particle accelerators, Montreux, Switzerland, 1998, 5: 399-427.
Baidu ScholarGoogle Scholar
[5] Masaki M and Takano S.

Beam size measurement of the Spring-8 storage ring by two-dimensional inter-ferometer

. Proceedings of beam diagnostics and instrumentation for particle accelerator, Grenoble, France, 2001, 5: 142-144.
Baidu ScholarGoogle Scholar
[6] Naito T and Mitsuhashi T.

Improvement of the resolution of SR interferometer at KEK-ATF damping ring

. Proceedings of the international particle conference, Kyoto, Japan, 2010, 5: 972-974.
Baidu ScholarGoogle Scholar
[7] Fisher A S, Holtzapple R L, Petree M, et al.

Beam-size measurements on PEP-II using synchrotron-light interferometer

. Proceedings of PAC2011, Chicago, 2001, 6: 547-549.
Baidu ScholarGoogle Scholar
[8] Born M, Wolf E. Principles of optics. Cambridge University Press, Cambridge, 7th edition, 1999, chapter, 7-10.
[9] Tang L L, Sun B G, Wang J G, et al.

Application of the Gige vision digital camera for beam diagnostics in HLS

. Proceedings of IPAC2010, 2010, 5: 1041-1043.
Baidu ScholarGoogle Scholar
[10] Dierks F.

Sensitivity and image quality of digital cameras. Technical report

, Basler AG, 2004, 10.
Baidu ScholarGoogle Scholar