1. Introduction
The spent fuel pool (SFP) is one of the most important equipment in the nuclear power plant. It plays a major role in removing the decay heat and shielding the radiation produced by the spent fuel during the process of spent fuel storage. After the Fukushima nuclear accident in 2011, investigations on the thermal-hydraulic characteristics and the safety performance of the spent fuel pool have become the research focus in the world.
In 2012, China promulgated an 863 project named “nuclear safety research”. One of the sub-topics is aimed to analyze and improve the safety of the spent fuel pool for generation II+ pressurized water reactor, such as CPR1000 which is the major reactor type in service or in construction in China. However, the cooling system of the SFP for generation II+ PWR is depending on the driving forces. Once without the driving forces, the water of the SFP will be boiling and the fuel will be melt. The passive safety systems were put forward in the 1980s, which depend on the gravity and natural circulation instead of operator actions or electronic feedback in the emergency event. The passive system has been widely applied in generation III reactors, such as the Westinghouse AP1000[1], the Japanese N.G.P, the Chinese ACPR1000[2], the Russian VVER, the PIUS with inherent safety features designed by ABB Power Generation Ltd. in Switzerland[3], the PWR with SIP-1 presented by SIET laboratory in Italy[4], and so on.
After Fukushima accident, a number of researchers have studied the safety of the spent fuel pool. Carlos et al. used TRACE thermal-hydraulic code to simulate the steady state and transient conditions with a loss of cooling and coolant of spent fuel pools. Their calculations of steady state have a good agreement with the measurements of Maine Yankee[5]. Chen et al. have developed a 3-D CFD model to analyze the localized distributions of the flow and heat transfer of the spent fuel pool in a loss of cooling event. The results show that the temperature rising rate calculated by the 3-D CFD is identical to that calculated by Procedure 597.1 for the Maanshan NPP[6]. Wang et al. applied RELAP5 to investigate the behavior of the spent fuel pool for CPR1000 with loss of heat sink[7].
Some researchers have developed the advanced passive safety system for SFP. Arndt B et al.[8] introduced a design based on the concept of cooling the spent fuel storage pool only depending on air cooling. Westinghouse Corporation[9] designed a floating passive cooling system using gravitate heat pipe principle to manage the spent fuel pool cooling. Their system is composed of many modular gravitate heat pipes. Each heat pipe may at most remove 300 kW of heat, and the cooling system can control the temperature of the pool water under 60
In order to take away the decay heat of the SFP effectively, the heat exchanger used in nuclear industry needs to be studied to improve heat exchange efficiency. Heat exchange efficiency is determined mainly by the structures of heat exchangers. Partial modification of the tubular heat exchanger can raise its heat exchange efficiency. Ye et al. [11] and You et al. [12] developed a powerful numerical model tool to predict the thermal hydraulic performances of the shell-and-tube heat exchanger, and they found the shell-and-tube heat exchanger (STHXs) with flower baffles has a better overall thermal hydraulic performance than the STHXs with segmental baffles. Then they conducted the experimental and numerical investigations of shell-side thermo-hydraulic performances for the STHXs with trefoil-hole baffles. Both results showed the heat transfer rate on the shell-side of the STHXs with trefoil-hole baffles was significantly enhanced, and the flow resistance increased substantially as well.
In the present paper, a passive system with air cooling for the SFP of CPR1000 is designed to control its water temperature under 80
2. Thermal-hydraulic design of passive cooling system
The CPR1000 (improved Chinese PWR) which is based on the French 900MW PWR with upgraded net power output of 1000 MW is the main reactor type in service and under construction in China. So its safety behavior is a critical issue for Chinese nuclear industry.
When SBO accident takes place, the water temperature of the SFP will continue to rise until boiling. If no active cooling measures are available, the water will evaporate away. Then the radioactive materials will release into the environment to cause danger. The passive cooling system is applied to remove the decay heat effectively and control the water temperature below an acceptable level when the active devices failure or loss of heat sink occurs.
The sketch of the designed passive cooling system is shown in Fig.1. The heat exchangers in the SFP and air are all shell-and-tube type. The SFP heat exchanger is immersed in the pool around the pool wall to load or unload the spent fuels assemblies conveniently. Water is used as the working fluid in the closed loop. The atmosphere is used as the final heat sink. The air cooling heat exchanger is equipped with uniform section circular fins to increase the heat transfer area.
-201601/1001-8042-27-01-008/alternativeImage/1001-8042-27-01-008-F001.jpg)
Under normal operating conditions, the tube side of the heat exchangers and the connecting pipes are filled with water and isolated by a check valve and an isolation valve. After the SBO occurs, the check and isolation valves will open automatically and the passive cooling system will start to work automatically without any active operation. The water heated in the SFP heat exchanger flows upward and enters the tube side of the air cooling heat exchanger, where it is cooled by the shell side air by natural convection. Finally, the cooled water flows back to the tube side of the SFP heat exchanger by gravity. Consequently, the passive SFP cooling system removes the decay heat by natural circulation under station blackout accident.
2.1. The heat transfer model in the passive cooling system
Ignoring the fouling resistance, the total heat transfer coefficient correlations for SFP and air heat exchangers based on tube outer surface are respectively as
In Eq. (2),
-201601/1001-8042-27-01-008/alternativeImage/1001-8042-27-01-008-F002.jpg)
The heat transfer equation is as following form:
In Eq. (3),
The heat transfer coefficient between the wall and water in the tubes of the SFP or air cooling heat exchanger is calculated by Churchill-Chu correlation[14]:
Where,
The Churchill-Chu correlation is reported to be valid over the full laminar and turbulent Rayleigh number range. It is usually used for natural convection, especially for a vertical flat plate.
For the heat exchanger without fins, the heat transfer mode between the tube outer wall and the coolant belongs to natural convection in infinite space. For the heat exchanger with fins, the heat transfer mode may belong to natural convection in infinite space or natural convection in finite space depending on the situation. Seigel et al.[15] found if the ratio of the fin pitch to fin height is larger than 0.28, the heat transfer mode between the fins and the coolant is natural convection in infinite space. Otherwise, it will be natural convection in finite space. The natural convection heat transfer correlation in infinite space is as follows[13]:
The natural convection heat transfer correlations in vertical and horizontal finite space can be presented respectively as follows[13]:
Eq. (10) is fully applicable to gas. But for liquid, considering the relation between the properties and the temperature, the right side of this equation should be multiplied by a correction factor depending on the property change. So the heat transfer correlation for the tube outside is modified as
In the Eq. (8)- (11), C, n and m are determined by experiments, depending on the heat transfer surface shape and position, turbulent or laminar flow, and thermal boundary conditions. Their values can be found in the literatures[13].
2.2. The pressure drop model in the passive cooling system
The establishment of the stable natural circulation is based on the situation that the pressure drop produced by the density difference between the riser and downcomer must overcome the resistance pressure drop in the loop:
Where,
The elevation pressure drop:
The frictional pressure drop:
The elbow, junction or valve pressure drop:
The area abrupt contraction pressure drop:
The area abrupt expansion pressure drop:
The heat exchanger tube pressure drop:
Where, K is form drag coefficient;
2.3. Thermal-hydraulics design
According to the design basis of the spent fuel pool for CPR1000, the max permissible temperature of the pool water is 80℃. In this paper, 80℃ is designed as the final temperature of the spent fuel pool in a loss of heat sink event. The environment temperature is designed to 30℃. According to the target, the numbers of the SFP heat exchanges tubes
The first step is to calculate the outlet temperature of the SFP heat exchanger
SFP heat exchanger | Air cooling heat exchanger | |||||
---|---|---|---|---|---|---|
Tube length/m | Tube type | Tube length/m | Tube type | Fin height/m | Fin thickness/m | Fin distance/m |
6.5 | φ25×2.5 | 12.0 | φ25×2.5 | 0.03 | 0.002 | 0.01 |
The detailed calculation procedure is shown in Fig. 3.
-201601/1001-8042-27-01-008/alternativeImage/1001-8042-27-01-008-F003.jpg)
Other parameters of the passive cooling system are assumed as Table 2. The power of the spent fuel assemblies is set to 11.98MW, which is the maximum power in abnormal conditions.
Parameters | Values |
---|---|
Environment temperature (℃) | 30 |
Pool temperature (℃) | 80 |
Inlet temperature of the SPF heat exchanger (℃) | 35 |
Mass flow of the passive cooling loop (kg/s) | 65 |
Diameter of the passive cooling loop pipe (m) | 0.3 |
Power of the spent fuel assemblies (MW) | 11.98 |
Working fluid | Water |
The number of each heat exchanger tubes and height difference between the two heat exchangers are calculated by the design parameters, as shown in Table 3. The height difference is 3.8m, which is easy to achieve from the view of engineering. These results indicate the designed passive cooling system for the spent fuel pool of CPR 1000 is practical significance.
Parameters | Values |
---|---|
The number of the SPF heat exchanger tubes | 6627 |
The number of the air heat exchanger tubes | 19086 |
Height difference (m) | 3.8 |
2.4. Height difference sensitivity analysis
As shown in section 2.3, the establishment of the stable natural circulation is based on the situation that the pressure drop produced by the density difference between riser and downcomer must overcome the resistance pressure drop of the loop. So the height difference between the bottom of the air heat exchanger and the top of the SFP heat exchanger which has a significant influence on pressure drop will affect the stable natural circulation.
Fig. 4 shows the curve of the mass flow of the passive cooling loop with the height difference.
-201601/1001-8042-27-01-008/alternativeImage/1001-8042-27-01-008-F004.jpg)
Keeping other parameters constant, the numbers of the air and SPF heat exchangers tubes are changed with the height difference between the bottom of the air heat exchanger and the top of the SFP heat exchanger. Fig. 5 and Fig. 6 show the curves of numbers of the air and SFP heat exchangers tubes with the height difference respectively. As they show, the number of SFP heat exchanger tubes decreased as height difference increased; while the number of the air cooling heat exchanger tubes increased.
-201601/1001-8042-27-01-008/alternativeImage/1001-8042-27-01-008-F005.jpg)
-201601/1001-8042-27-01-008/alternativeImage/1001-8042-27-01-008-F006.jpg)
This is because the mass flow of the natural circulation increases with the height difference. According to Eq. (19),
where the decay heat
The ratio of the material area is defined as the ratio of the material area of the passive cooling system and the minimum of them. Fig. 7 shows the curve of the ratio of the material area with height difference. In terms of economy, the height difference is better between 3 to 10 meters.
-201601/1001-8042-27-01-008/alternativeImage/1001-8042-27-01-008-F007.jpg)
3. The passive cooling system performance analysis based on RELAP5
This section will use RELAP5 to analyze the designed passive cooling system, taking the result of section 2 as the input conditions. We need to verify whether the passive cooling system can control the pool temperature at 80℃ after loss of heat sink occurs.
3.1. RELAP5 code introduction
RELAP5 developed by the Idaho National Engineering Laboratory for the U.S. Nuclear Regulatory Commission, is a general system code for transient behavior analysis, used as the basis for a nuclear plant analyzer. RELAP5 adopts the two-phase flow model and uses the semi-implicit algorithm or nearly-implicit algorithm to solve the model. It can simulate transients in LWR systems such as loss of coolant (LOCA), anticipated transients without scram (ATWS), and operational transients such as loss of feedwater, loss of offsite power, station blackout (SBO), and turbine trip. RELAP5 is a highly generic code that it can simulate a wide variety of thermal-hydraulic transients in both nuclear and nonnuclear systems involving mixtures of steam, water, noncondensable gas and solute.
3.2. The passive cooling system for CPR1000 SFP
A nodalization of the passive cooling system for the SFP is shown in Fig. 8. Control volume 271 and 276 represent the SFP and air cooling heat exchangers respectively. Control volume 272 and 277 represent the riser and downcomer of the loop respectively. 287 is the valve at the downcomer, and must be opened immediately to remove the decay heat when the loss of heat sink occurs.
-201601/1001-8042-27-01-008/alternativeImage/1001-8042-27-01-008-F008.jpg)
Fig. 9 shows the coolant mass flow change of the passive cooling system. The mass flux increases rapidly to 46.3 kg·s-1 at 100 seconds after the accident. Early in the accident the large temperature difference between the SFP and air heat exchangers causes the large density difference and a large driving force in the loop.
-201601/1001-8042-27-01-008/alternativeImage/1001-8042-27-01-008-F009.jpg)
As Fig. 10 shows, early in the accident the thermal load of the heat exchanger rises rapidly, but still under the decay heat of the spent fuel (11.98 MW). So the passive cooling system can’t remove the decay heat, and the temperature of the pool surface increases continually, shown in Fig. 11.
-201601/1001-8042-27-01-008/alternativeImage/1001-8042-27-01-008-F010.jpg)
-201601/1001-8042-27-01-008/alternativeImage/1001-8042-27-01-008-F011.jpg)
The increase of the water temperature results in a larger temperature difference between the cold and heat sources of the loop. Moreover, the driving force of the coolant increases, and the coolant mass flux increases with it. Meanwhile the heat load of the heat exchanger increases until 11.98 MW to remove the decay heat of the spent fuel exactly. After that every parameter remains constant. It means the passive cooling system has been established successfully.
As shown in Fig. 11, the temperature of the pool surface is 80℃ after the establishment of the passive system. Fig. 12 shows the inlet temperature of the SFP heat exchanger is 35℃. They certify the passive cooling system we designed is effective.
-201601/1001-8042-27-01-008/alternativeImage/1001-8042-27-01-008-F012.jpg)
4. Conclusion
In this paper, a passive cooling system for the SFP of CPR1000 is designed. The passive cooling system can maintain the temperature of the SFP around 80
Then the height difference sensitivity was analyzed. The result shows that the number of SFP heat exchanger tubes decreased as height difference increased; while the number of the air cooling heat exchanger tubes increased.
The loss of heat sink accident of the spent fuel storage pool with the passive cooling system was analyzed by RELAP5-MOD3.3, which used the theoretical calculation as the input. After the accident, the temperature of the pool surface increased continually until 80.5
Westinghouse AP1000 advanced passive plant
. Nucl Eng Des, 2006,236:1547-1557. DOI: 10.1016/j.nucengdes.2006.03.049Application and development of passive technology in nuclear power units
. Proceedings of the CSEE, 2013,33:81-89.IAEA activities on passive safety systems and overview of international development
. Nucl Eng Des, 2000,201:41-59. DOI: 10.1016/S0029-5493(00)00260-0Two new passive safety systems for LWR applications
. Nucl Eng Des, 2000,200:383-396. DOI: 10.1016/S0029-5493(00)00256-9Use of TRACE best estimate code to analyze spent fuel storage pools safety
. Prog Nucl Energ, 2014,77:224-238. DOI: 10.1016/j.pnucene.2014.07.008CFD simulating the transient thermal-hydraulic characteristics in a 17× 17 bundle for a spent fuel pool under the loss of external cooling system accident
. Ann Nucl Energy, 2014,73:241-249. DOI: 10.1016/j.anucene.2014.06.054ICONE21-16503: Safety Analysis of CPR1000 Spent Fuel Pool in Case of Loss of Heat Sink
, theIAEA-CN-102/17: Advanced spent fuel storage pools
.The design and simulation of a new spent fuel pool passive cooling system