Pinhole imaging to observe spatial jitters of a triple-pulse X-ray source on the Dragon-II LIA

SYNCHROTRON RADIATION TECHNOLOGY AND APPLICATIONS

Pinhole imaging to observe spatial jitters of a triple-pulse X-ray source on the Dragon-II LIA

Yi Wang
Zhi-Yong Yang
Xiao-Bing Jing
Qin Li
Heng-Song Ding
Zhi-Yong Dai
Nuclear Science and TechniquesVol.27, No.5Article number 110Published in print 20 Oct 2016Available online 26 Aug 2016
45600

In high-energy flash radiography, scattered photons degrade the acquiring image, which limits the resolving power of interfaces and density of dense object. The application of large anti-scatter grid can reduce the scattered photons remarkably, but this requires a stable source position in order to reduce the loss of signal photons in the grid structure. The pinhole imaging technique is applied to observe spatial jitters of a triple-pulse radiographic source of a linear induction accelerator. Numerical simulations are conducted to analyze the imaging performance with the same or close parameters of the pinhole object and experimental alignment. Experiments are carried out to observe spatial jitters of the source between different measurements. Deviations of the source position between different pulses are measured in each experiment.

Spatial jitterX-ray sourcePinhole imagingLinear induction accelerator

1. Introduction

Flash radiography is an extraordinary diagnostic technique to investigate the hydrodynamic process of high explosives[1]. The radiographic source is generally produced by a linear induction accelerator (LIA). Electron beam pulses are accelerated to ~MeV and focused onto a high-Z convertor target to generate X-rays (bremsstrahlung)[2-6]. The temporal width of an E-beam pulse is usually tens of nanoseconds, which enables a recording of an inner stopped-motion image of a dense object. In flash radiography, photon scattering is a major obstacle for acquiring fine details of interfaces and object density[7,8].

Efforts were devoted to investigations of photon scatter properties and anti-scatter techniques, including various kinds of collimators made of heavy materials to reduce scatter background and improve contrast in radiography[9-11]. However, the collimators placed between the object and the light source is usually accompanied with a loss of abaxial image information of the object. The Los Alamos National Laboratory developed a structure of large anti-scatter grid of high grid ratios and the scattered photons can be remarkably reduced for radiography[12]. The scintillator array of image-receiving system is directly pinned to the grid, the correspondence of which is perfectly matched to be one-scintillator-pixel to one-grid-hole. Since the anti-scatter grid is designed to fit the directions in which radiation photons are emitted, it ought to be strictly aligned to focus exactly at the center of the light source. A spatial jitter of the source can result in a loss of primary radiation in the grid structure[13]. The higher the grid ratio is, the more sensitively the source spatial jitter would degrade the image.

In this paper, the pinhole imaging technique[14,15] is applied to measure spatial position of a triple-pulse X-ray source produced by the Dragon-II LIA. The acquiring image denotes a two-dimensional distribution of the X-ray source, by which the spatial position of the source centroid can be obtained. Experiments are performed to observe spatial jitters of the source between different measurements. The interpulse differences of the source centroid are measured in each experiment.

2. Principle and setup

In flash radiography, photons from the X-ray source pass through the objects in the light field and finally reach the image receiving system. The spatial distribution of radiographic image i(x,y) is a convolution of the source spatial distribution s(x,y), the transmitted intensity distribution of object o(x,y), and the detector response to a point X-ray source r(x,y), i.e.

i(x,y) =s(x,y)*o(x,y)*r(x,y), (1)

where the sign * denotes the convolution operation. The modulation transfer function (MTF) of a radiographic system is simply the product of MTFs of each component[16], and a Fourier transform of Eq. (1) can be done to obtain Eq.(2)

I(fx,fy) =S(fx,fy)·O(fx,fy)·R(fx,fy), (2)

where I, S, O and R stand for MTFs of each component in Eq. (1). A sketch of pinhole imaging setup is illustrated in Fig. 1. A pinhole object is placed between the X-ray source and the image receiving system. For an ideal pinhole, the spatial intensity distribution o(x,y) can be described by the delta function δ(x,y), which denotes the MTF of O(fx,fy)=1. The geometrical magnification of the experimental arrangement M is defined as the ratio of the pinhole-image distance b to the source-pinhole distance a. If the blurring of image recording system is ignored in the setup with a large magnification, the relation of the source MTF and the image MTF will be simplified as

Fig. 1
Sketch of pinhole imaging setup.
pic
I(fx,fy)S(fx,fy). (3)

So, spatial distribution of the image is exactly a reflection of the source. Then the relation between the source centroid P0(x,y) and the image centroid P(x,y) can be expressed as

P0(x,y) = P(x,y)/M, (4)

where the negative sign indicates opposite directions of the image position and the source position.

3. Numerical simulations

The precondition of a tenable relation between the source and image positions given by Eq. (4) is to image the source with an ideal pinhole, i.e. an infinitesimally small hole through an infinitesimally thin and completely opaque sheet[17]. This, however, cannot be realized in practice, especially with penetrating X-rays, high-Z materials are used to construct the pinhole object, which ought to be thick enough to make the “opaque” sheet. The pinhole aperture cannot be too small either because the view field shall cover enough area of the source. Besides, the screen blur effect should be considered.

Here we perform numerical simulations to analyze the pinhole imaging process with the same or close parameters of the object and the experimental alignment. Monte Carlo method[18,19] is applied to simulate the X-ray generation by striking an electron beam of 19.0 MeV onto a tantalum target of 1.2 mm thickness and transmitting the photons through a tungsten pinhole object of 65 mm thickness with an aperture of 0.47 mm. Then we calculate the convolution of the transmitted photon intensity distribution with the point-spread function (PSF) of the screen blur as the obtained image. The source-pinhole distance is a=1119 mm and the pinhole-image distance is b=4681 mm. The PSF of screen blur is assumed to a Gaussian function with the standard deviation of 0.7 mm, according to measurement result by the edge response technique[20].

In the simulation, a Gaussian function is used to model spatial distribution of the source, with the FWHM being 1.0 mm at first. The source center (x, y) is located (in mm) at (2, 0), (−2, 0), (0, 2) or (0, −2). For each simulation, the sampling amount is 106. The simulated images are shown in Fig. 2. Because the pinhole imaging process is not rotationally symmetric when the source is laterally decentered, we calculate the image centroid within boundaries containing 90% or 50% of the photon intensity sum (PIS). The corresponding source centroid is worked out according to Eq. (4). Table 1 shows the calculated source centroid (P0cal) and the set source position (P0setl). ΔL=|P0calP0setl|, the distance between the calculated and the set source positions, is superior to 0.1 mm with a 2-mm source displacement from the origin. The source FWHMs of 1.5 and 2.0 mm are then calculated and listed in Table 1. The results of P0cal show a good agreement with the results of P0setl.

Table 1
The set and calculated source positions by numerical simulations (in mm)
Source FWHM Set P0(x,y) Calculated P0(x,y)
    90%PIS ΔL 50%PIS ΔL
1.0 (2.000,0.000) (2.063,0.002) 0.063 (2.056,0.002) 0.056
  (−2.000,0.000) (−2.017,0.001) 0.017 (−2.024,0.003) 0.024
  (0.000,2.000) (0.022,2.042) 0.047 (0.020,2.046) 0.050
  (0.000,−2.000) (0.022,−2.039) 0.044 (0.014,−2.044) 0.046
1.5 (2.000,0.000) (2.045,0.005) 0.045 (2.034,-0.002) 0.034
  (−2.000,0.000) (−1.977,0.000) 0.023 (−1.989,0.005) 0.012
  (0.000,2.000) (0.034,2.015) 0.037 (0.020,2.010) 0.022
  (0.000,−2.000) (0.031,−2.011) 0.033 (0.018,−2.009) 0.020
2.0 (2.000,0.000) (2.017,0.004) 0.017 (1.995,-0.011) 0.012
(−2.000,0.000) (−1.928,-0.002) 0.072 (−1.940,0.004) 0.060
(0.000,2.000) (0.044,1.978) 0.049 (0.019,1.967) 0.038
(0.000,−2.000) (0.040,−1.974) 0.048 (0.028,−1.972) 0.040
Show more
Fig. 2
Simulated of pinhole images at different source positions (in mm) . The white and the black dashes denote the boundaries of 90% PIS and 50% PIS, respectively. The source FWHM is 1.0 mm.
pic

4. Measurements of the source position

Experiments are performed to observe the source position of the Dragon-II LIA, which generates triple X-ray pulses of ~60 ns in pulse length, and ~400 ns spacing between neighboring pulses. A lead collimator is placed just in front of the radiographic source as a radiation shield of the area away from the central field. A 65-mm thick tungsten bar with a pinhole of 0.47 mm diameter is precisely placed along the central axis (z-axis). The image receiving system consists of an LYSO scintillator screen, a flat mirror tilted at 45º with respect to z-direction, and a framing camera to record each pulse image. The camera is composed of an optical framing element and several intensifier CCD cameras, and its gating time is controlled by a high-speed micro channel plank. Precisions of the trigger time and exposure time are less than 5 ns. By inputting external trigger synchronization signals, the camera records each pulse image separately. The experimental alignment is a=1119 mm and b=4681 mm, hence a magnification of M=4.183. The experiments are conducted with electron beams of 18.9 MeV and 2.05 kA, trying to maintain a steady and identical state for all pulses. The pinhole object is placed close to the source to obtain a large magnification so as to acquired image in a better resolution and reduce the image blur effect. According to the parameters of the pinhole object and the experimental alignment, the view field width for the source reaches 15.7 mm, which is about ten times the source FWHM, so collimating effect of the pinhole object can be neglected.

Typical images of the triple-pulse X-ray source obtained by the pinhole imaging technique are shown in Fig. 3. The conversion ratio of the image pixel to the spatial distance is 0.104 mm/pixel. In order to correct pixel-to-pixel variations of the screen sensitivity and dark current of the camera, a standard procedure for gain and offset modification is applied to the images[21]. Besides, relative displacements of the origin and azimuths of the axes are corrected for different framing images. The source centroids of triple pulses are calculated, considering both the image boundary of 90%PIS and that of 50%PIS. The experimental results of X-ray source centroid are listed in Table 2. For each pulse, the center and radius of a minimum circle which contains all centroid positions in different measurements are used to denote the center and the range of source centroid jitters (Fig.4). For the boundary of 90%PIS, the jitter radii of the triple-pulse source centroid are 0.155, 0.153 and 0.072 mm for Pulses A, B and C, respectively. The deviation distances between the source-jitter centers of each pulse pair are LAB=0.690 mm, LBC=1.349 mm and LAC=0.674 mm. For the boundary of 50%PIS, the jitter radii are RA=0.188 mm, RB=0.213 mm and RC=0.125 mm; and the deviation distances are LAB=0.673 mm, LBC=1.295 mm and LAC=0.700 mm. The spatial jitters of the source centroid are relatively small for each pulse. However, deviations of the source positions are distinct between different pulses, because of, most probably, corkscrew oscillation of the electron beam due to tilted beam injections, inaccurate alignments of solenoid field, and energy spread of the electron beam [22,23].

Table 2
Experiment results of spatial position of the source centroid
Exp. No. Pulses E (MeV) I (kA) P 0(x,y) (mm)
        90%PIS 50%PIS
#1 A 18.9 2.04 (0.000, −0.099) (0.022, −0.073)
  B 18.9 1.98 (0.709, 0.230) (0.627, 0.374)
  C 18.8 2.07 (−0.562, -0.296) (−0.532, −0.110)
#2 A 19.0 2.03 (0.023, −0.341) (0.007, −0.342)
  B 18.8 2.04 (0.685, 0.048) (0.668, 0.195)
  C 18.7 2.08 (−0.567, −0.401) (−0.491, −0.261)
#3 A 19.0 2.05 (−0.039, −0.353) (−0.037, −0.367)
  B 19.0 2.08 (0.611, −0.032) (0.561, 0.034)
  C 18.9 2.09 (−0.633, −0.420) (−0.547, −0.254)
#4 A 19.0 2.06 (0.041, −0.321) (0.088, −0.347)
  B 18.9 2.06 (0.659, 0.020) (0.707, 0.148)
  C 18.9 2.06 (−0.664, −0.387) (−0.658, −0.326)
#5 A 19.0 2.04 (0.035, −0.354) (0.044, −0.403)
  B 19.0 2.06 (0.646, −0.071) (0.659, −0.050)
  C 18.9 2.07 (−0.603, −0.380) (−0.503, −0.236)
#6 A 19.0 2.05 (0.150, −0.368) (0.210, −0.399)
  B 19.0 2.08 (0.730, −0.003) (0.721, 0.110)
  C 19.0 2.07 (−0.636, −0.398) (−0.536, −0.255)
Show more
Fig. 3
Typical images of triple-pulse x-ray source by the pinhole method. The inside and outside curves denote the boundaries of 50%PIS and 90%PIS, respectively.
pic
Fig. 4
Spatial jitters of triple-pulse X-ray source centroid, for centroid within 90%(a) and 50% (b) PIS boundary.
pic

5. Conclusion

Spatial jitters of the triple-pulse X-ray source generated by the Dragon-II LIA are measured using the pinhole imaging technique. For flash radiography with a large anti-scatter grid, the spatial jitter of each X-ray pulse and the deviation between different pulses should be smaller than 0.5 mm for reducing direct radiation loss[24]. Numerical simulations are performed for the source position measurement, and the obtained source centroid agree well with the set one. In each measurement, images of triple pulses are obtained, and the centroids are calculated within 90%PIS or 50%PIS boundaries. For each pulse, the spatial jitter of source centroid is small. However, centroids of different pulses deviate distinctively from each other. For a flash radiographic system of large anti-scatter grid to provide stable and uniform positions of all pulses, the X-ray source should be optimized by reducing the electron beam injection tilt, accurate aligning the magnetic field, and decreasing energy spread of the electron beam.

References
1. T.P. Hughes, D.C. Moir and R.L. Carlson.

Upgrade of the PHERMEX accelerator

, Conference Record of the 1991 IEEE Particle Accelerator Conference, Vols 1-5: Accelerator Science And Technology, 1991.
Baidu ScholarGoogle Scholar
2. P. Allison, M.J. Burns, G.J. Caporaso, et al.

Beam-breakup calculation for the DARHT accelerator

, Conference Record of the 1991 IEEE Particle Accelerator Conference, Vols 1-5: Accelerator Science And Technology, 1991.
Baidu ScholarGoogle Scholar
3. C. Ekdahl.

Modern electron accelerators for radiography

. IEEE Transactions on Plasma Science, 2002, 30: 254-261.
Baidu ScholarGoogle Scholar
4. B.T. McCuistian, O. Abeyta, P. Aragon, et al.

DARHT-II commissioning status

, PPC-2003: 14th IFFF International Pulsed Power Conference, Vols 1 And 2, Digest Of Technical Papers, 2003.
Baidu ScholarGoogle Scholar
5. J. Deng, B. Ding, H. Wang, et al.

Physical design of the Dragon-I linear induction accelerator

. High Power Laser and Particle Beams, 2003, 15: 502-504 (in Chinese).
Baidu ScholarGoogle Scholar
6. B.N. Ding, J.J. Deng, H.C. Wang, et al.

Dragon-I linear induction electron accelerator

. High Energy Physics and Nuclear Physics-Chinese Edition, 2005, 29: 604-610 (in Chinese).
Baidu ScholarGoogle Scholar
7. B. Li, J. Shi, J. Liu, et al.

Numerical simulation of distribution of scattered exposure and reduced scatter in flash radiographic system

. High Power Laser and Particle Beams, 2005, 17: 788-792 (in Chinese).
Baidu ScholarGoogle Scholar
8. J. Shi, B. Li, J. Liu, et al.

Analytic determination of scatter exposure for radiography

. High Power Laser and Particle Beams, 2006, 18: 1211-1214 (in Chinese).
Baidu ScholarGoogle Scholar
9. J.L. Gerstenmayer, M. Nicolaizeau and P. Vibert. Multi-hole graded collimator—Quantitative tomographic measurements, Ultrahigh- and High-Speed Photography, Videography, and Photonics, 1993.
10. F.J. Goldin and S. Mitchell.

Collimated step-wedge spectrometer for flash X-ray radiography sources

. Hard X-ray and Gamma-ray Detector Physics V, 2004, 5198: 126-133. DOI: 10.1117/12.503868
Baidu ScholarGoogle Scholar
11. Z. Xiao, J. Liu, B. Hu, et al.

Experimental research of the performance of graded collimators in high-energy flash X-ray radiography

. Nuclear Electronics and Detection Technology, 2007, 27: 512-515 (in Chinese).
Baidu ScholarGoogle Scholar
12. S.A. Watson, M. Appleby, J. Klinger, et al.

Design, fabrication and testing of a large anti-scatter grid for Megavolt gamma-ray imaging

, 2005 IEEE Nuclear Science Symposium Conference Record, Vols 1-5, 2005.
Baidu ScholarGoogle Scholar
13. T. Tsunoo, N. Nakamori, H. Kanamori, et al.

The influences of incorrect placement of the focused grid an X-ray image formation

. Physics Of Medical Imaging, 1998, 3336: 651-659. DOI: 10.1117/12.317070
Baidu ScholarGoogle Scholar
14. Y. Kiwamoto, Y. Kikuchi, T. Takahashi, et al.

Pinhole camera imaging of X-rays and energetic neutral atoms for hot plasma diagnostics

. Review Of Scientific Instruments, 1998, 69: 2574-2575. DOI: 10.1063/1.1148962
Baidu ScholarGoogle Scholar
15. W. Leitenberger, H. Wendrock, L. Bischoff, et al.

Pinhole interferometry with coherent hard X-rays

. J. Synchrotron Radiation, 2004, 11: 190-197. DOI: 10.1107/s0909049503029169
Baidu ScholarGoogle Scholar
16. E. Samei, M.J. Flynn and D.A. Reimann.

A method for measuring the presampled MTF of digital radiographic systems using an edge test device

. Medical Physics, 1998, 25: 102-113. DOI: 10.1118/1.598165
Baidu ScholarGoogle Scholar
17. C. Ekdahl.

Characterizing flash-radiography source spots

. Journal Of the Optical Society Of America A-Optics Image Science And Vision, 2011, 28: 2501-2509.
Baidu ScholarGoogle Scholar
18. S. Agostinelli, J. Allison, K. Amako, et al.

GEANT4-a simulation toolkit

. Nucl Instr & Meth in Phys Res Section A, 2003, 506: 250-303. DOI: 10.1016/s0168-9002(03)01368-8
Baidu ScholarGoogle Scholar
19. D. Sardari, R. Maleki, H. Samavat, et al.

Measurement of depth-dose of linear accelerator and simulation by use of Geant4 computer code. Reports of practical oncology and radiotherapy

, J Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology, 2010, 15: 64-8. DOI: 10.1016/j.rpor.2010.03.001
Baidu ScholarGoogle Scholar
20. J.M. Boone and J.A. Seibert.

An analytical edge spread function model for computer fitting and subsequent calculation of the LSF and MTF

. Medical Physics, 1994, 21: 1541-1545. DOI: 10.1118/1.597264
Baidu ScholarGoogle Scholar
21. A. Karellas, L.J. Harris, H. Liu, et al.

Charge-coupled device detector — performance considerations and potential for small-field mammographic imaging applications

. Medical Physics, 1992, 19: 1015-1023. DOI: 10.1118/1.596819
Baidu ScholarGoogle Scholar
22. Y.J. Chen.

Corkscrew modes in linear accelerators

. Nucl Instr & Meth In Phys Res Section A, 1990, 292: 455-464. DOI: 10.1016/0168-9002(90)90403-s
Baidu ScholarGoogle Scholar
23. W. Zhang, Z. Dai, H. Li, et al.

Beam instability and correction for "Dragon-I"

, 2007 IEEE Particle Accelerator Conference, Vols 1-11, 2007.
Baidu ScholarGoogle Scholar
24. H.B. Xu, Y. Ye, N. Zheng.

Influence of source out of focused grid on image in high-energy X-ray radiography

. High Power Laser and Particle Beams, 2015, 27: 115103. DOI: 10.11884/HPLPB201527.115103(in Chinese)
Baidu ScholarGoogle Scholar