1 Introduction
The Shanghai Synchrotron Radiation Facility (SSRF) is the third synchrotron radiation light source facility in Shanghai China, which can produce broad rates of X-rays for primary scientific research and applications in other domains. To produce high brilliance pulses, bunch length and beam emittance should be regulated within appropriate ranges. Moreover, the bunch length is an important factor of the overall beam performance.
Bunch length was previously measured at the SSRF using a streak-camera [1]. Bunch-by-bunch measurements can be obtained, and a resolution of 2 ps can be achieved using this method. However, the performance of this method requires complicated optical structures and continuous operator monitoring to address operational contingencies. Moreover, the measurement mechanism involved makes it difficult to follow dynamical changes in the bunch length [1-7]. Thus, a real-time measurement or analysis method is required at the SSRF for daily operation.
The two-frequency method provides a means of indirectly measuring the bunch length in the frequency domain. Average bunch length measurements by this method at CERN have provided a resolution of about 0.7 ps [8]. The two-frequency method employs an electronic system that can provide on-line bunch-by-bunch measurements and be integrated into the EPICS control network if configured with the development of the beam diagnostics technique at the SSRF.
A two-frequency measurement system is comprised of radio frequency (RF) front end electronics, a real-time data acquisition module, and a high level data analysis package. Working frequencies of 3 GHz and 500 MHz were selected, and the RF front end was designed and constructed on the basis of these two frequencies. A high sampling rate multi-channel oscilloscope served as a convenient data acquisition device, and the raw data was resampled and analyzed using the MATLAB software platform. The constructed system was employed to study the bunch length synchronous oscillation phenomenon during injection, and further beam experiments confirm the relationship between bunch length and bunch charge.
2 Principles and Analysis
The longitudinal charge distribution of an electron bunch in a storage ring is typically Gaussian, and the Fourier component of the mi-th harmonic is given as
where ω0 is the RF frequency 499.68 MHz employed at the SSRF, and V0 is the DC component. In the two-frequency method, the bunch length, σ, is obtained as the ratio between two Fourier components as follows [8-19]:
Here, V1 and V2 are the actual measured value of the m1-th and m2-th harmonics, where the m2 is greater than m1, and K is a coefficient that depends on the two frequencies.
When a bunch runs across from the electrical center of beam-position monitor (BPM), there is an influence by transverse deviation, but it can be dispelled. The response coefficients of the pickup and analog front end vary at different frequencies, and both contribute to the value of K. However, K is a constant for the two specified frequencies on a fixed system.
For independent V1 and V2, the uncertainty of the bunch length is propagated from the two signals:
where Δ V1, Δ V2, and Δ are the resolutions of the output signals V1 and V2, and the error propagation, respectively. In most occasions, the signal-to-noise ratios (SNR) of V1 and V2 are close enough that SNR(V1) =SNR(V2) = SNR(V) stands. In that case, the relative resolution of the calculated bunch length can be estimated:
The resolution will suffer a severe enlargement during the calculation when
3 Measurement System Setup
A block diagram of the bunch length measurement system including RF front-end electronics, timing module, and a digital oscilloscope is shown in Fig. 1.
-201707/1001-8042-28-07-004/alternativeImage/1001-8042-28-07-004-F001.jpg)
The beam signal derived from a button-type pickup is divided into two channels by a 2-way 0-degree power splitter. Each channel incorporates a corresponding band pass filter with center frequencies of 500 MHz or 3 GHz to obtain signals at the working frequencies. The timing module produces a 2.5 GHz clock signal serving as a local oscillator (LO) employed in conjunction with a mixer to output an intermediate frequency of 500 MHz from the filtered 3 GHz signal. The digital oscilloscope then acquires data from both channels after the adjusted channel signal has passed through another 500 MHz band pass filter. Figure 2 presents a photograph of the RF-front end employed in the measurements.
-201707/1001-8042-28-07-004/alternativeImage/1001-8042-28-07-004-F002.jpg)
The 500 MHz band pass filter was a very significant component of our measurement system.
Figure 3 presents an S-parameter chart of the WI Corp. 500 MHz band pass filter obtained by the network analyzer in laboratory. The filter bandwidth is 350 MHz to 650 MHz, which can ensure the bandwidth required for bunch-by-bunch measurement. Moreover, the S-parameter chart indicates that transmission outside of the band is reduced from 40 dB to 50 dB, which reliably suppresses other high order harmonics.
-201707/1001-8042-28-07-004/alternativeImage/1001-8042-28-07-004-F003.jpg)
Real-time bunch-by-bunch measurement requires two frequency signals synchronized with the machine RF signal. Therefore the 2.5 GHz LO input signal of the mixer must be generated according to a timing signal that is phase locked to the machine RF signal. A programmable wide band frequency synthesizer, (EVAL-ADF4351, ADI Corp.), was employed to this. The EVAL-ADF4351 is a phase-locked loop (PLL) evaluation unit with an integrated voltage controlled oscillator (VCO) whose input reference frequency is 250 MHz at maximum and with an output frequency range from 35 MHz to 4.4 GHz. In our application, the revolution frequency of 694 KHz from the timing system is employed as the input reference, and the multiplication factor of 3600 was configured to output a 2.4984 GHz signal. The amplitude response of this module is shown in Fig. 4, as measured using a Tektronix RSA6114A network analyzer.
-201707/1001-8042-28-07-004/alternativeImage/1001-8042-28-07-004-F004.jpg)
The phase noise of the sideband is less than -27.1 dBc/Hz, which obviously cannot have a large impact on the intermediate frequency signals of the mixer because its power is insufficient to support mixing. Actual experiments reveal that different frequencies signals can be reliably locked.
A digital oscilloscope is adopted as a DAQ device due to its high dynamic range. However, the sampling rate of the raw data captured by the oscilloscope is 5 GHz, which is not synchronized with the machine RF signal. Therefore, a software resampling technique was required in the data analysis procedure [20]. The MATLAB software platform was employed to this purpose. The RF frequency obtained from the discrete Fourier transformation of the raw waveform was employed to determine the bunch interval. Cubic spline interpolation was used to obtain bunch-by-bunch length information at accurate signal phases. With the resampled amplitude information, the bunch charge and length can be calculated correctly at the bunch-by-bunch rate.
4 Beam Experiments
Suitable beam experiments must be conducted to verify the functionality of the proposed bunch length measurement system. An ideal beam experiment involves adjusting the RF cavity voltage to change the bunch length and then compares the measured value with the expected value. However, the SSRF is a multiple-user facility, and this test is therefore impractical. Another suitable and performable choice is the observation of the beam injection transient, which is frequently observable in the top-up operation mode at the SSRF, where the bunch length of the refilled bunch varies considerably during injection.
4.1 Observation of Beam Injection Transient
Bunch injection induces damping betatron oscillation due to the timing mismatch of kickers and damping synchronous oscillation due to the phase mismatch of refilled charge. Figure 5 presents a conceptual model of the effect of the injection transient.
-201707/1001-8042-28-07-004/alternativeImage/1001-8042-28-07-004-F005.jpg)
The refilled bunch is a conjunction of the originally stored charge and the small, newly injected charge. After injection, the injected charge oscillates around the stored charge in the longitudinal plane, which creates a corresponding bunch length oscillation, the amplitude of which decreases gradually. The oscillation frequency is double that of the SSRF storage ring synchrotron frequency.
A practical beam experiment was conducted using a 240 mA beam on April 11th, 2016. The relative bunch charge information was retrieved from the channel one (500 MHz) data. The turn index of injection can be determined by comparing raw waveforms of the stored and refilled bunches, which is shown in Fig. 6.
-201707/1001-8042-28-07-004/alternativeImage/1001-8042-28-07-004-F006.jpg)
With the correct injection turn index, the filling pattern before and after injection can be calculated, as shown in Fig. 7. Subtraction of the two patterns provides the refilled bunch indices, which are 419–425 in this case.
-201707/1001-8042-28-07-004/alternativeImage/1001-8042-28-07-004-F007.jpg)
Figure 8 presents a waterfall plot indicative of the measured bunch length. The bunch length oscillation of the refilled bunches (419–425, given by the light yellow dashed line in Fig. 8) can be observed as well.
-201707/1001-8042-28-07-004/alternativeImage/1001-8042-28-07-004-F008.jpg)
Figure 9 presents a plot of the refilled bunch length as a function of the turn index, which clearly demonstrates the synchronous oscillation illustrated in Fig. 5 due to the merging of the stored charge and injected charge. As a reference, the stored bunch is plotted as well by the blue line, demonstrating a very stable bunch length over the period of the procedure. In this case, the accelerator phase of the injected charge is not matched with the synchronous phase of the stored charge, resulting in a gradually decreasing amplitude of oscillation, as shown by the red curve in the plot.
-201707/1001-8042-28-07-004/alternativeImage/1001-8042-28-07-004-F009.jpg)
If we conduct a Fourier analysis of the refilled bunch oscillation and the stored bunch, we attain their frequency spectrum, as shown in Fig. 10. We find its highest peak resides at the second harmonics of the normalized frequency of 0.007 and the third and fourth harmonics are notable comparing with the stored bunch line, which matches the synchrotron frequency of the SSRF exactly. These results verify that our bunch length measurement system was constructed correctly and operated successfully.
-201707/1001-8042-28-07-004/alternativeImage/1001-8042-28-07-004-F010.jpg)
5 Measurement Resolution
The standard deviation of the bunch length was 1.11 ps and it became 4.05 ps after the injection (as shown in Fig. 11).
-201707/1001-8042-28-07-004/alternativeImage/1001-8042-28-07-004-F011.jpg)
According to Eq. (3) or Eq. (4), the measurement resolution is restrained by the SNR. The SNR of the electronics was obtained by measuring the signals from the button with stored beams and without filling any bucket. Setting up an appropriate scale, the amplitudes of the signals with beams were around 120 mV, and the standard deviation of the noise is about 0.58 mV. 4 data points near the peak were used to determine the output voltage of a bunch during the experiment, so the SNR gains a boost by a factor of 2. Applying m1ω0=2π×500 MHz, m2ω0=2π×3 GHz,
6 Conclusion
Bunch-by-bunch measurement of the bunch length is an important tool that can facilitate the daily monitoring of the SSRF storage ring and act as a supplement to streak-camera absolute measurement of the bunch length.
The present work discussed the construction of an electronic system employing the two-frequency method that achieves bunch length measurements at the bunch-by-bunch rate. Bunch injection experiments accurately disclosed the phenomenon of bunch length synchronous oscillation, and the fusing process of the injected bunch and the stored one was observed for the first time. A time resolution of no more than 0.5 ps was demonstrated for the proposed design.
Bunch lenth measurement with streak camera at SSRF storage ring
, inReal time bunch length measurements in the SLC linac
, IEEE Transactions on Nuclear Science 32, 2006-2008, (1985). doi: 10.1109/TNS.1985.4333796Streak-camera measurements of the PEP-II high-energy ring
, AIP Conference Proceedings 451, 471-478, (1998). doi: 10.1063/1.57033Precise measurement of a subpicosecond electron single bunch by the femtosecond streak camera
, Nucl. Instrum. Meth. A, 406, 371-379 (1998). doi: 10.1016/s0168-9002(97)01220-5Subpicosecond electron single-beam diagnostics by a coherent transition radiation interferometer and a streak camera
, Nucl. Instrum. Meth. A, 437, 1-11 (1999). doi: 10.1016/s0168-9002(99)00674-9Sub-picosecond bunch length measurement at the TESLA test facility
, Nucl. Instrum. Meth. A, 445, 343-347 (2000). doi: 10.1016/s0168-9002(00)00140-6The bunch length measurement of BEPC with a streak camera
, inNon-intercepting bunch length monitor for picosecond electron bunches
, inHigh-resolution bunch-length monitor capable of measuring an rms value of a few mm
, Nucl. Instrum. Meth. A, 361, 430-435 (1995). doi: 10.1109/pac.1997.751089Electromagnetic simulations and RF measurements results of an ultra-short bunch length monitor
, inBunch length measurement and the beam signal observation through high power RF waveguide system, Technical Report, SLAC-PUB-10359
, doi: 10.2172/826787An RF bunch-length monitor for the SLC final focus
[C]//Bunch length measurement using beam spectrum (CESR storage ring)
, inBunch lengthening study in BEPC
,Bunch length monitor using two-frequency analysis for RF gun system
. Japanese journal of applied physics, 2004, 43(11R): 7747. DOI: 10.1143/jjap.43.7747Studies of bunch lengthening at the BEPC