logo

Calculation of response of Chinese hamster cells to ions based on track structure theory

Calculation of response of Chinese hamster cells to ions based on track structure theory

Liu Xiao-Wei
Zhang Chun-Xiang
Nuclear Science and TechniquesVol.8, No.4pp.243-245Published in print 01 Nov 1997
38100

Considering biological cells as single target two-hit detectors, an analytic formula to calculate the response of cells to ions is developed based on track structure theory. In the calculation, the splitting deposition energy between ion kill mode and γ kill mode is not used. The results of calculation are in agreement with the experimental data for response of Chinese hamster cells, whose response to γ rays can be described by the response function of single target two hit detector to ions.

Chinese hamster cellsTrack theoryIonsDose response
References
1 Butts J J, Katz R. Radiation Research, 1967; 30: 855
2 Katz R, Sharma S C, Homayoonfar M.

The structure of particle tracks

. In: Attix F H, ed. Radiation dosimetry, Supplement 1. New York: Academic Press, 1972; 317-383
Baidu ScholarGoogle Scholar
3 Zhang Chun-Xiang, Dunn D E, Katz R. Radiat Prot Dosim, 1985; 13: 215
4 Liu Xiao-Wei, Li Mian-Feng, Yu K N. Physics in Medicine and Biology, 1994; 39: 1757
5 Liu Xiao-Wei, Li Miang-Feng, Luo Da-Ling et al. Int J Radiat Biol, 1996; 70(2): 227
6 Skarsgard L D, Kihlman B A, Parker I et al. Radiat Res Suppl, 1967; 7: 208
7 Katz R, Ackerson B, Homayoonfar M et al. Radiat Res, 1971; 47: 402