logo

DOSE RESPONSE CURVE OF 60Co FOR PREMATURE CONDENSED CHROMOSOME FRAGMENTS OF HUMAN LYMPHOCYTES

DOSE RESPONSE CURVE OF 60Co FOR PREMATURE CONDENSED CHROMOSOME FRAGMENTS OF HUMAN LYMPHOCYTES

Gao Jinsheng
Zheng Siying
Jiang Haiyan
Bao Hong
Nuclear Science and TechniquesVol.6, No.3pp.183-187Published in print 01 Aug 1995
32400

The dose-response curves obtained by premature condensed chromosome (PCC) and conventional cellular genetic methods can be represented by two linear equations. The ratio of the slopes, KPCC/KM1, is about 28. In comparison to the conventional method, the PCC method has many advantages; e.g. it is faster, simpler, more sensitive and accurate. Its significance in the study of radiation damage is also discussed.

Dose response relationships60CoMenLymphocytesPremature condensed chromosome
References
1 Johnson R T, Rao P N. Nature, 1970; 226: 717
2 Pantelias G E, Maillie H D. Somatic Cell Genetic, 1983; 9(5): 533
3 Crossen P E, Morgan W F. Exp Cell Res, 1977; 104: 453
4 Pantelias G E, Maillie H D. Radiat Res, 1984; 99: 140
5 Bertsche U. Radiat Environ Biophys, 1988; 27: 201
6 Jin Cut Zhen. Irradiation Safeguard, 1988; 8(4/5): 391
7 Cornforth M N, Bedford J S. Science, 1983; 222: 1141
8 Maillie H D, Baker J V. Health Physics, 1986; 51: 672