logo

High-resolution SPECT for small-animal imaging

ADVANCED NUCLEAR INSTRUMENTATION AND DETECTION

High-resolution SPECT for small-animal imaging

QI Yu-Jin
Nuclear Science and TechniquesVol.17, No.3pp.164-169Published in print 20 Jun 2006
32700

This article presents a brief overview of the development of high-resolution SPECT for small-animal imaging. A pinhole collimator has been used for high-resolution animal SPECT to provide better spatial resolution and detection efficiency in comparison with a parallel-hole collimator. The theory of imaging characteristics of the pinhole collimator is presented and the designs of the pinhole aperture are discussed. The detector technologies used for the development of small-animal SPECT and the recent advances are presented. The evolving trend of small-animal SPECT is toward a multi-pinhole and a multi-detector system to obtain a high resolution and also a high detection efficiency.

Small-animal SPECTMolecular imagingPinhole collimationGamma camera
References
[1] Cherry S R, Phys. Med. Biol. 2004, 49:R13-R48.
[2] Weissleder R, Mahmood U, Radiology, 2001, 219:316-333.
[3] Weissleder R, Cancer Reviews, Nature, 2002, 2:1-8.
[4] Budinger T F, Benaron D A, Koretsky A P, Annual Review, Annu. Rev. Biomed. Eng. 1999, 1: 611-648.
[5] Weber D A, Ivanovic M, Franceschi D, et al. Journal of Nuclear Medicine, 1994, 35: 342-348.
[6] Jaszczak R, Li J, Wang H, et al. Phys Med Biol, 1994, 39: 425-443.
[7] Weber D A, Ivanovic M, Journal of Nuclear Medicine, 1995, 36: 2287-2289.
[8] Yokoi T, Kishi H, Kaku Igaku-Japanese Journal of Nuclear Medicine, 1998, 35: 901-907.
[9] Wu M C, Tang H R, O'Connell J W, et al. IEEE Transactions on Nuclear Science, 1999, 46: 1199-1202.
[10] Tsui B M W, Wang Y, Frey E C, et al. Journal of Nuclear Medicine, 2001, 42(5): 54P-55P.
[11] Kastis G A, Barber H B, Barrett H H, et al. Journal of Nuclear Medicine, 1998, 39: 9P.
[12] McElroy D P, MacDonald L R, Beekman F J, et al. IEEE Trans. Nucl. Sci., 2002, 49: 2139-2147.
[13] Wojcik R, Goode A R, Smith M, et al. IEEE Nuclear Science Symposium Conference Record, 2003, 3: 1819-1823.
[14] Qi Y J, Tsui B M W, Wang Y, et al.

Development and characterization of a high-resolution microSPECT system for small animal imaging

, In: Kupinski M A, Barrett H H (ed), Small-animal SPECT imaging, Springer Press, 2005: 259-266,.
Baidu ScholarGoogle Scholar
[15] Anger H O,

Radioisotope cameras

, In: Instrumentation in nuclear medicine, Vol.1, Hine G J, ed. New York: Academic Press, 1967: 485-552.
Baidu ScholarGoogle Scholar
[16] Barrett H H, Swindell W, Radioological imaging: The theory of imaging formation, detection, and processing, Vol. 1 & 2, New York: Academic Press, 1981.
[17] Tsui B M W, Gunter D, Beck R, et al.

Physics of collimator design

, In: Sandler C R, Wackers FJTh, Patton J A, et al. (ed). Diagnostic nuclear medicine, Vol. 1, Third Edition, Baltimore William and Wilkins, 1996: 67-80.
Baidu ScholarGoogle Scholar
[18] Metzler S D, Bowsher J E, Smith M F, et al. IEEE Transactions on Medical Imaging, 2001, 20(8): 730-741.
[19] Metzler S D, Bowsher J E, Greer K L, et al. IEEE Transactions on Medical Imaging, 2002, 21: 878-887.
[20] Gieles M, de Jong H W A M, Beekman F J. Phys. Med. Biol. 2002, 47(11): 1853-1867.
[21] Qi Y, Tsui B M W, Wang Y, et al. Journal of Nuclear Medicine, 2004, 45 (5), Suppl: 442.
[22] Smith M F, Jaszczak R J, Wang H.,. IEEE Transactions on Nuclear Science, 1997, 44(3): 1154-1160.
[23] Wojcik R, Majewski S, Steinbach D, et al. IEEE Transactions on Nuclear Science, 1998, 45(3): 487-491.
[24] Weisenberger A G, Kross B, Majewski S, et al. IEEE Transactions on Nuclear Science, 1998, 45(6): 3053-3058.
[25] Pani R, Soluri A, Scafe R, et al. IEEE Transactions on Nuclear Science, 1999, 46: 702-708.
[26] Levin C S, Hoffman E J, Tornai M P, et al. IEEE Transactions on Nuclear Science, 1997, 44(4): 1513-1520.
[27] Kastis G A, Barber H B, Barrett H H, et al. IEEE Transactions on Nuclear Science, 2000, 47: 1923-1927.
[28] Kastis G A, Furenlid L R, Wilson D W, et al. IEEE Transactions on Nuclear Science, 2004, 51: 63-67.
[29] Weisenberger A G., Wojcik R., Bradley E L, et al. IEEE Transactions on Nuclear Science, 2003, 50: 74-79.
[30] MacDonald L R, Patt B E, Iwanczyk J S, et al. IEEE Transactions on Nuclear Science, 2001, 48: 830-836.
[31] Schramm N U, Ebel G, Engeland U, et al. IEEE Transactions on Nuclear Science, 2003, 50: 315-320.
[32] Mok Seng Peng, Tsui M W, Wang Yuchuan, et al. IEEE Nuclear Science Symposium Conference Record, 2004, 6: 3340-3444.
[33] Meikle S R, Kench P, Weisenberger A G, et al. IEEE Transactions on Nuclear Science, 2002, 49: 2167-2171.
[34] Accorsi R, Gasparini F, Lanza R C. IEEE Transactions on Nuclear Science, 2001, 48(6): 2411-2417.
[35] Beekman F J, Vastenhouw B, IEEE Nuclear Science Symposium Conference Record, 2002, 2: 792-796.
[36] Beekman F J, van der Have F, Vastenhouw B, et al. Journal of Nuclear Medicine, 2005, 46: 1194-1200.