logo

Optically stimulated luminescence dosimeter based on CaS:Eu,Sm

ADVANCED NUCLEAR INSTRUMENTATION AND DETECTION

Optically stimulated luminescence dosimeter based on CaS:Eu,Sm

LIU Yanping
CHEN Zhaoyang
BA Weizhen
FAN Yanwei
GUO Qi
YU Xuefeng
CHANG Aiming
LU Wu
DU Yanzhao
Nuclear Science and TechniquesVol.19, No.2pp.113-116Published in print 20 Apr 2008
47800

Alkaline earth sulfides (MgS, CaS and BaS) crystal doped with rare-earth ions is an optically stimulated luminescence dosimeter with very high sensitivity, short time constant of the optically stimulated luminescence (OSL) separated perfectly from the stimulation. In this paper, an OSL dosimeter is described. It has linear dose response from 0.01 to 1000 Gy. The equipment, relatively simple and small in size is promising for applications in space exploration and for high dose irradiation and dangerous irradiation conditions.

Optically stimulated luminescenceRadiation measurementRadiation dosimeter
References
[1] Dusseau L, Plattard D, Vaille J R, et al. IEEE Trans Nucl Sci, 2000, 47: 2412-2416.
[2] Fowler J F, Attix F H. Radiat Dosim, 1966, 2: 241-290.
[3] Lindmayer J. Solid State Technol, 1988, 31: 135-138.
[4] Bogorad A, Bowman C, Dennis A, et al. IEEE Trans Nucl Sci, 1995, 42: 2051-2057.
[5] MacKay G F, Thomson I, Sultan N, et al. IEEE Trans Nucl Sci, 1997, 44: 2048-2051.
[6] Dusseau L, Polge G, Albert L, et al. IEEE Trans Nucl Sci, 1998, 45: 2695-2699.
[7] Wang S J, Zhang H. Sci China Ser G (Phys Mech Astron), 2007, 50: 53-69.
[8] Buhler P, Desorgher L, Zehnder A, et al. Radiat Meas, 1996, 26: 917-921.
[9] Mackay G F, Thomson I, Sultan N, et al. IEEE Trans Nucl Sci 1997, 44: 2048-2051.
[10] Huntley D J, Godfrey-Smith D I, Thewaltet M, et al. Nature, 1985, 313: 105-107.
[11] Jutanulia S, Storti G M, Seideman W, et al. Appl Opt, 1990, 29: 4806-4811.
[12] Bogorad A, Bowman C, Dennis A, et al. IEEE Trans Nucl Sci, 1995, 42: 2051-2057.
[13] Dusseau L, Polge G, Mathias S, et al. IEEE Trans Nucl Sci, 2001, 48: 2056-2060.
[14] Idri K, Santoro L, Charpiot E, et al. IEEE Trans Nucl Sci, 2004, 51: 3638-3641.
[15] Boetter J L, McKeever S W S, Wintle A G, et al. Optically Stimulated Luminescence Dosimetry. Elsevier Science (1 edition), Oct 24, 2003, 2-10.
[16] Yamashita N, Asano S. J Phys Soc Jpn, 1987, 56: 352-358.
[17] Barbier L, Cheret M. J Phys, 1983, B16: 3213-3228.
[18] Akselrod M S, Agersnap-Larsen N, McKeever S W S, et al. Radiat Meas, 2000, 32: 215-225.
[19] Akselrod M S, Akselrod A E, Agersnap-Larsen N, et al. Radiat Prot Dosim, 1999, 85: 125-128.
[20] Akselrod M S, Lucas A C, Polf J C, et al. Radiat Meas, 1998, 29: 391-399.
[21] Akselrod M S, McKeever S W S. Radiat Prot Dosim, 1999, 81: 167-176.
[22] Akselrod M S, Yoder R C, Akselrod G M, et al. Radiat Prot Dosim, 2006, 119: 357-362.
[23] Chen R, Lockwood D J. J Electrochem Soc, 2002, 149: S69-S78.
[24] Trocmé M, Higueret S, Husson D, et al. Radiat Prot Dosim, 2007, 126: 536-540.