The safety shutter of the SR (synchrotron radiation) facility located at the front end of the facility is an indispensable component for radiation protection. Its thickness is decided by the gas bremsstrahlung produced in the SR facility storage ring by the interaction of electrons with the residual gas molecules in the vacuum chamber of the storage ring. In the calculation, the 3.5GeV, 300mA electron beam and a 15m long insertion-device straight section (0.133μPa) were taken into account, and the safety shutter was assumed to be located 12m away from the end of the straight section. The EGSnrc code based on the Monte-Carlo method and empirical formulas were used, respectively, to calculate the thickness to satisfy the shielding requirement of the safety shutter at the front end of the SR facility, and the results were compared and the availability of EGSnrc was proved.

SR facilitySafety shutterMonte-Carlo methodEGSnrc code
References
[1] Tromba G, Rindi A. Nucl. Instr and Meth in Phys Res, 1990, A292: 700.
[2] National Shanghai Synchrotron Radiation Facility Center, Shanghai Synchrotron Radiation Facility Preliminary Design, P6-1, 2001
[3] Job P K, Haeffner D R, Shu D. Bremsstrahlung scattering calculations for the beam stops and collimators in the APS insertion-device beamlines, ANL/APS/TB-20, 1993.
[4] Ferrari A, Pelliccioni M, Sala P R. Nucl. Instr and Meth in Phys Res, 1993, B83: 518.
[5] Kawrakow I, Hirayama H, Rogers D W O. The EGSnrc Code System. Canada: National Research Council of Canada. 2003:14-15.
[6] Ipe N, Haeffner D R, Alp E E, et al. Guide to beamline radiation shielding design at the advanced photon source, ANL/APS/TB-7, 1994.
[7] Berger M J, Hubbell J H, Seltzer S M, et al. XCOM: Photon cross sections database, NBSIR 87-3597, 2005.
[8] Ipe N I, Fasso A. Impact of gas bremsstrahlung on synchrotron radiation beamline shielding at the advanced photon source, Slac-Pub-6410, 1994.