SSRF diagnostics system will adopt a new generation digital electron beam position processor, Libera, as the signal condition, signal processing and data acquisition device for beam position monitor. In order to provide a uniform data and control interface for users, we developed an EPICS interface based on Control System Programming Interface (CSPI) layer, allowing the performance of the electron beam to be monitored through EPICS channels. In this interface a new record type for BPM was defined and its associated support routines were implemented.