logo

A mathematical method to calculate efficiency of BF3 detectors

ADVANCED NUCLEAR INSTRUMENTATION AND DETECTION

A mathematical method to calculate efficiency of BF3 detectors

SI Fenni
HU Qingyuan
PENG Taiping
Nuclear Science and TechniquesVol.20, No.3pp.181-183Published in print 20 Jun 2009
37401

In order to calculate absolute efficiency of the BF3 detector, MCNP/4C code is applied to calculate relative efficiency of the BF3 detector first, and then absolute efficiency is figured out through mathematical techniques. Finally an energy response curve of the BF3 detector for 1~20 MeV neutrons is derived. It turns out that efficiency of BF3 detector are relatively uniform for 2~16 MeV neutrons.

BF3 detectorAbsolute efficiencyRelative efficiencyEnergy response curve
References
[1] Kushneriuk S A. Canadian Journal of Physics, 1952, 30(5): 402-411.
[2] DING Dazhao, YE Chuntang, ZHAO Zhixiang, et al. Nutron Phys. 2nd Ed. Beijing: Atomic Energy Press. 2005: 129-168 (in Chinese).
[3] Pszona S. Nucl Instr and Meth, 1998, 402(1): 139-142.
[4] Kim G N, Lee Y S, Son D.

Pohang Neutron Facility Based on 100-MeV Electron Linac

. In: Proceedings of the second Asian Particle Accelerator Conference. Beijing, 2001.
Baidu ScholarGoogle Scholar
[5] ZHANG Guohui, CHEN Jinxiang. At Energy Sci Technol, 2007, 41(1): 22-25 (in Chinese).
[6] XU Shuyan. Application of Monte Carlo method in experimental nuclear physics. 2nd Ed. Beijing: Atomic Energy Press. 2006: 1-18 (in Chinese).
[7] Chien-Yi Chen, Chien Chung. Nucl Instr Meth, 1997, 395(2): 195-201.
[8] Hason A O, Mckibben J L. Phys Rev, 1947, 72(8): 673-677.
[9] X-5 Monte Carlo Team. MCNP5—A General Monte Carlo N-Particle Transport Code, Version 5. USA: Los Alamos National Laboratory. 2003: 1-19.
[10] Keller S E, Heuser B J, Carpenter J M. Physica B, 1997, 241: 30-32.
[11] Bourva L C A, Croft S, Ottmar H, et al. Nucl Instrum Methods Phys Res Part A, 1999, 426(2-3): 503-517.
[12] Takeda N, Kudo K, Toyokawa H, et al. Nucl Instrum Methods, 1999, 422(1-3): 600-605.
[13] Nasrabadi M N, Jalali M, Mohammadi A. Nucl Instrum Methods, 2007, 263(2): 473-476.
[14] Iki E, Besshou S, Ogata K. Fusion Eng Des, 1997, 34: 603-606.