Introduction
Since the 1970s, computed tomography (CT) has been developed into a powerful tool for industrial non-destructive testing (NDT), in which the structural integrity of assembled devices is assessed and the quality of manufactured components is inspected. The main focus of NDT applications is qualitative feature recognition (or visualization), such as flaw detection, morphological characterization of internal structures, and material wear inspection. With the development of state-of-the-art precision engineering (e.g., additive manufacturing [1, 2]), there is an increasing demand for accurate dimensional measurements to assure manufacturing quality (e.g., wall thickness, pore size, and geometry tolerance verification) without destroying the part. The CT technique plays a significant role in dimensional metrology [3-6], especially for the dimensional determination of the internal or hidden structures of a component.
In industrial CT systems, X-rays are generally produced by the so-called bremsstrahlung, which is a process in which high-energy electrons are braked by an anode and a continuous spectrum is produced. Because the X-ray absorption of a material is energy dependent, beam-hardening artifacts occur when a polychromatic spectrum is used for CT reconstruction. Owing to the influence of beam-hardening artifacts, serious errors occur in dimensional measurements [7-11], which hamper accurate quantitative analysis and inspection. Since the invention of CT techniques, several methods have been developed to correct this influence. However, those correction algorithms have their own limitations, such as the reduction of photon flux by pre-filtering, the requirement of prior knowledge of the imaging materials or spectrum [8, 10, 12-22], two scans at preferably non-overlapping spectra [23, 24], and computational complexity [21, 22, 25-28]. To resolve the beam-hardening effect fundamentally, it is necessary to develop a monochromatic X-ray source; in particular, a monochromatic gamma-ray source with strong penetration power for industrial high-Z material imaging that is characterized by high beam quality, a suitable footprint, and a moderate cost.
With the development of high-brightness electron beams and high-power lasers, the inverse Compton scattering (ICS, also called Thomson scattering in the low-energy region [29, 30]) gamma-ray source has been developed as an excellent light source for advanced gamma-ray imaging because it can provide quasi-monochromatic, continuously energy-tunable, small-focal-spot, and high-brightness gamma rays [31-33]. Furthermore, the footprint of this type of light source is at the room or container scale, making it flexible for clinical or industrial NDT applications. Therefore, ICS light sources have recently attracted significant attention in the field of advanced radiation imaging, including monochromatic and spectral imaging [34-37], phase contrast imaging [38-42], polarization-based imaging [43, 44], and nuclear resonance fluorescence imaging [45-49]. For an ICS light source, the gamma-ray photon energy Eγ in a head-on interaction geometry between the relativistic electron and laser, and considering the relativistic approximation (_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-M001.png)
To improve the imaging efficiency of gamma-ray CT based on ICS light sources, the imaging FOV must be increased without reducing the beam intensity, which means that special efforts must be made to correct the influence of the intrinsic energy-angle correlation spectrum of this type of light source on CT reconstruction. In this study, a dual-energy scan scheme is proposed to realize large-FOV gamma-ray CT by taking full advantage of the straightforward energy tunability of ICS light sources. The feasibility of this scheme was investigated based on a typical ICS light source using Monte Carlo simulations.
Methods
Principle of gamma-ray dual-energy scan scheme
According to the interaction mechanism between X-ray photons and materials, the linear attenuation coefficient μ(E) of a material can be decomposed into three parts:_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-M002.png)
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-M003.png)
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-M004.png)
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-M005.png)
In the low-energy region (E<1.022 MeV), the pair production process cannot occur. Hence, only the photoelectric and Compton scattering terms in Eq. (2) contribute to the linear attenuation coefficient μ(E). For the photoelectric term, fPE(E) is empirically considered as 1/E3 when no electron-shell discontinuity occurs in the given energy region, which restricts the model to application to very-high-Z materials. For the Compton scattering term, fCS(E) is explicitly described by the well-known Klein–Nishina formula, which assumes the unbound electron and at-rest conditions, neglecting the incoherent scattering function and Doppler broadening, respectively. Using dual-energy CT scans, the projections of aPE and aCS can be calculated, based on which the spatial distribution of aPE and aCS can be reconstructed. Thus, a monochromatic CT image of the imaging object can be obtained using Eq. (2) by neglecting the pair production term. This is the principle of the dual-energy method for beam-hardening correction in the diagnostic X-ray energy region [23, 24], which has been applied to energy-angle correlation correction for monochromatic CT based on an ICS light source in the keV energy region [35].
In the high-energy region (e.g., hundreds of keV to several MeVs), the contribution of the photoelectric effect to the linear attenuation coefficient μ(E) is usually negligible compared with those of the Compton scattering and pair production terms. In principle, the spatial distributions of aCS and aPP for an imaging object can also be reconstructed using a dual-energy scan. However, no explicit expression for fPP(E) exists owing to the complex energy dependence of the pair production effect. In this case, the basis material decomposition model is often adopted [51].
In the basis material decomposition model, an arbitrary material can be considered as a mixture of two basis materials and its linear attenuation coefficient μ(E) can be decomposed as_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-M006.png)
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-M007.png)
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-M008.png)
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-M009.png)
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-M010.png)
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-M011.png)
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-M012.png)
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-M013.png)
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-M014.png)
The gamma-ray energy of an ICS light source can be easily adjusted by changing either the electron energy or interaction angle between the electron and laser. The influence of the energy-angle correlation spectrum encountered in a large-FOV imaging geometry using ICS light sources on CT reconstruction can be easily resolved using a dual-energy scan. Although an energy-angle correlation exists in the scan of each gamma-ray peak energy, the local quasi-monochromaticity [δ(E) approximation] at an arbitrary detection angle of the FOV (or an arbitrary detection position within the gamma-ray beam profile) can be satisfied (see Sect. 2.2 for the simulated gamma-ray spectra). Hence, two projections at different gamma-ray energies (EH and EL) can be obtained at any detection angle of the FOV. The two gamma-ray energies EH and EL can be calculated using Eq. (1) when the gamma-ray peak energies (EH,max and EL,max) are determined, based on which the values of μBM,1 and μBM,2 can be obtained at the two gamma-ray energies EH and EL. By solving Eq. (7) and using the composition relation in Eq. (9), the projections of the imaging object at any detection angle of the FOV can be corrected to the same gamma-ray energy, as illustrated in Fig. 1. Therefore, a monochromatic CT image of the imaging object can be reconstructed.
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-F001.jpg)
Monte Carlo simulation
Monte Carlo (MC) simulations were performed using the Geant4 toolkit [52] to demonstrate the feasibility of the large-FOV gamma-ray CT scheme. The imaging geometry was modeled based on the imaging system constructed for the very compact ICS gamma-ray source (VIGAS) [53-55] that is under construction at Tsinghua University. A fan-beam geometry was adopted, and the imaging layout is illustrated in Fig. 2. Gamma-ray photons were generated from the IP (gamma-ray spot size 10 μm, rms) and propagated R1 = 10 m to the imaging object. The spectrum of the gamma-ray photons, as shown in Fig. 3, was generated from CAIN [56], which is the most commonly used MC code for ICS simulations, by considering the practical beam parameters of the VIGAS. The gamma-ray peak energies EL,max and EH,max of the dual-energy scan were 2 and 4 MeV, respectively. The imaging object was scanned separately by the two spectra. At the VIGAS, gamma rays with peak energies of 2 and 4 MeV were generated by the interaction of 290 MeV electrons and lasers with wavelengths of 800 and 400 nm, respectively. The CAIN simulation results of the gamma-ray spectrum were loaded into Geant4 for further imaging simulations. Both the energy-angle correlation and energy spread of the spectrum were considered in the MC simulation. To acquire the projection data of the imaging object, an ideal transmission detector with a pixel size of 0.2 mm was placed R2 = 0.5 m downstream of the imaging object. The photon intensity of the generated gamma rays of an ICS light source decreases with the detection angle, as shown in Fig. 3(a). To guarantee the necessary photon intensity at the boundary of the gamma-ray beam profile, the gamma-ray collection angle θc was selected as 1/γ (~1.76 mrad), which corresponds to an FOV of ~3.5 cm at the position of the imaging object. Compared with the quasi-monochromatic case (typical FOV of ~5 mm or less at 2 MeV), the FOV increases more than seven-fold in the dual-energy scan scheme.
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-F002.jpg)
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-F003.jpg)
The imaging object was an aluminum (Al) cylinder with a diameter of 3.0 cm, inside which there were four cylindrical columns with a diameter of 8.0 mm. The four inner columns were made of iron (Fe), copper (Cu), water (H2O), and silicon (Si), respectively. For the CT scan of the imaging object, the rotation axis was the central axis of the Al cylinder, located at the center of the gamma-ray beam.
In the MC simulation, 360 projections that were evenly distributed in the angular range of 0–360° were acquired for each CT scan. In each projection, 9×107 gamma-ray photons were simulated to balance the statistical error and time cost.
Image reconstruction
Based on the dual-energy scan scheme, the monochromatic projections of the imaging object at an arbitrary gamma-ray energy E could be obtained using Eq. (9). Monochromatic CT reconstruction of the imaging object at gamma-ray energies of 2 and 4 MeV was realized using the well-known ART-TV iterative algorithm.
Because monochromatic CT images of the imaging object at gamma-ray energies of 4 and 2 MeV were obtained, the effective atomic number Zeff and electron density ρe of the imaging object could also be obtained. By combining Eqs. (2) and (3), the linear attenuation coefficient of a material in the gamma-ray energy region can be expressed as_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-M015.png)
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-M016.png)
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-M017.png)
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-M018.png)
Results and discussion
The basis materials selected for the CT reconstruction of the imaging object were iron (Fe) and carbon (C), the linear attenuation coefficients of which can be found in the National Institute of Standards and Technology (NIST) [57]. The CT reconstruction results of the imaging object using the original energy-angle correlation spectrum with a gamma-ray peak energy of 2 MeV and the monochromatic CT reconstruction results at a gamma-ray energy of 2 MeV using the dual-energy scan scheme are illustrated in Figs. 4(a) and (b), respectively. To avoid the mosaic phenomenon in the CT reconstruction image caused by undersampling and to obtain a smooth reconstruction result, 512 × 512 pixels were selected in the CT reconstruction region, which led to a virtual resolution that was much higher than the practical resolution of the transmission detector. The horizontal and vertical center profiles of the reconstruction results are shown in Figs. 4(c) and (d), respectively, to provide a quantitative comparison. Similar CT reconstruction results at a gamma-ray energy of 4 MeV are illustrated in Fig. 5. Owing to the influence of the energy-angle correlation spectra, obvious cupping artifacts appeared in the reconstructed images. Using the dual-energy scan scheme described in Sect. 2.1, the cupping artifacts could be perfectly corrected, and the reconstructed linear attenuation coefficient of the imaging object agreed well with its theoretical value, as shown in Figs. 4(c), 4(d), 5(c), and 5(d). Considering that gamma-ray energy is correlated with the detection angle, different parts of the imaging object are irradiated by gamma rays with different energies. The energy-modified linear attenuation coefficient of the imaging object, which yields the theoretical μ(E) of the imaging object with the gamma-ray energy E calculated based on the energy-angle correlation relation in Eq. (1), is also illustrated in Figs. 4(c), 4(d), 5(c), and 5(d) using black dotted lines. The energy-modified linear attenuation coefficient of the imaging object exhibited a similar variation tendency to the reconstruction result using the original energy-angle correlation spectrum, in which the linear attenuation coefficient for the same material increased with the radius. However, a quantitative comparison shows that the two results do not agree well, particularly around the center of the imaging object. Therefore, the single-spectrum correction using the energy-angle correlation information in Eq. (1) cannot reflect the practical reconstruction results.
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-F004.jpg)
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-F005.jpg)
The electron density and effective atomic number of the imaging object reconstructed using the pre- and post-processing methods are shown in Figs. 6 and 7, respectively. For both reconstruction methods, the reconstruction quality of the electron density was much better than that of the effective atomic number, which can be attributed to the division operation in Eq. (12b). Compared with the pre-processing method, there were serious artifacts around the boundaries of H2O, Fe, and Cu in the Zeff image reconstructed using the post-processing method.
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-F006.jpg)
_2026_05/1001-8042-2026-05-92/alternativeImage/1001-8042-2026-05-92-F007.jpg)
To evaluate the reconstruction quality of the two methods quantitatively, five regions of interest (ROIs) were selected, as indicated by the white dotted squares in Figs. 6(a), 6(d), 7(a), and 7(d). The ρe and Zeff reconstruction results for the five materials are presented in Tables 1 and 2, respectively. Both the mean value and its standard error calculated over the ROIs are provided for the reconstructed values in Tables 1 and 2. In terms of ρe, the precision (standard error) of the five materials reconstructed using the post-processing method was much higher than the value using the pre-processing method. Meanwhile, the accuracy (relative error) of ρe reconstructed using the post-processing method was slightly higher than the value using the pre-processing method for all materials, except for Cu. In terms of Zeff, the reconstruction precision using the post-processing method was slightly lower than that using the pre-processing method for all materials except for H2O, and the reconstruction accuracy using the post-processing method was similar to that using the pre-processing method for all materials except for H2O. Therefore, the post-processing method is more suitable for ρe reconstruction, whereas the pre-processing method is more suitable for Zeff reconstruction. For moderate-Z materials (e.g., Fe and Cu), excellent reconstruction was obtained, with accuracies of less than 3% and 1.5% for ρe and Zeff, respectively. For Fe, the relative errors of ρe and Zeff were the smallest, which was expected because Fe is a basis material. For relatively low-Z materials (e.g., Al, Si, and H2O), the lower ρe reconstruction accuracy may be attributed to the less accurate basis material decomposition of the linear attenuation coefficient. Basis material decomposition models with higher accuracy must be developed in future studies to improve the reconstruction accuracy of ρe. In addition, the gamma-ray energy selected for the dual-energy scan may be a reason for the high relative errors of the ρe and Zeff reconstruction for these low-Z materials. Because gamma-ray energies of 2 and 4 MeV are too high for low-Z materials in the imaging object, the statistical error of the monochromatic CT reconstruction was relatively high, as shown in Figs. 4(d) and 5(d), which resulted in a high relative error in the ρe and Zeff reconstruction. To reduce the relative errors of ρe and Zeff caused by the selection of gamma-ray energy for the dual-energy scan, the photon number used for the MC simulation should be increased or the gamma-ray energy should be reduced. Although the pre-processing method for Zeff reconstruction has advantages over the post-processing method in terms of boundary artifact suppression and high-precision reconstruction, the reconstruction precision of Zeff owing to the division operation in Eq. (12b) was significantly lower than that of ρe. Therefore, effective reconstruction methods must be developed to improve the reconstruction precision of Zeff.
| Material | Reference value (× NA cm-3) | Pre-processing | Post-processing | ||
|---|---|---|---|---|---|
| Reconstruction value (× NA cm-3) | Relative error (%) | Reconstruction value (× NA cm-3) | Relative error (%) | ||
| Al | 1.300 | 1.159±0.097 | 10.89 | 1.164±0.023 | 10.47 |
| Si | 1.162 | 1.053±0.092 | 9.35 | 1.063±0.016 | 8.50 |
| H2O | 0.555 | 0.461±0.099 | 16.92 | 0.470±0.020 | 15.35 |
| Fe | 3.666 | 3.651±0.088 | 0.42 | 3.654±0.023 | 0.32 |
| Cu | 4.089 | 4.196±0.093 | 2.62 | 4.198±0.023 | 2.67 |
| Material | Reference value | Pre-processing | Post-processing | ||
|---|---|---|---|---|---|
| Reconstruction value | Relative error (%) | Reconstruction value | Relative error (%) | ||
| Al | 13 | 12.58±2.69 | 3.21 | 12.66±2.88 | 2.58 |
| Si | 14 | 15.39±2.50 | 9.91 | 15.42±2.78 | 10.16 |
| H2O | 7.42 | 6.54±9.01 | 11.83 | 7.14±8.65 | 3.74 |
| Fe | 26 | 25.94±0.79 | 0.26 | 25.93±0.82 | 0.28 |
| Cu | 29 | 28.68±0.76 | 1.09 | 28.69±0.78 | 1.07 |
Because the FOV using the dual-energy scan scheme is increased by more than seven-fold compared with the quasi-monochromatic scan (translation + rotation scheme), the imaging time using the dual-energy scan scheme (only rotation is required) when CT scans using different gamma-ray energies are carried out separately can be reduced by at least 3.5 times. However, dual-color gamma rays can be easily produced simultaneously for an ICS light source [58-60] using one of the following three schemes: (i) dual-color lasers interacting with the same electron beam, (ii) a single-color laser interacting with the same electron beam at different interaction angles by beam splitting, and (iii) dual-color electron beams interacting with the same laser. Using dual-color gamma rays, a dual-energy scan can be realized simultaneously by combining it with a layered transmission detector (the front layer for low-energy gamma-ray detection and the rear layer for high-energy gamma-ray detection, as in the case of early dual-energy CT [61, 62]). Therefore, the imaging time can be reduced further by 2 times. Another advantage of the dual-energy scan scheme compared with the quasi-monochromatic scan is that the ρe and Zeff of the imaging object can be obtained simultaneously.
Conclusion
Quasi-monochromatic, continuously energy-tunable, and high-brightness gamma rays produced by ICS light sources can fundamentally resolve beam-hardening artifacts in CT reconstruction, which can improve the accuracy of quantitative analysis and inspection in CT-based dimensional metrology. An effective method for large-FOV imaging was developed to improve the imaging efficiency of gamma-ray CT using this type of light source. Using a dual-energy scan scheme, the influence of the intrinsic energy-angle correlation spectrum of ICS light sources on CT reconstruction was resolved, and a monochromatic CT image of the imaging object was accurately reconstructed. Furthermore, the electron density ρe and effective atomic number Zeff of the imaging object were obtained. For ρe reconstruction, the post-processing method has an obvious advantage over the pre-processing method; however, for Zeff reconstruction, the pre-processing method is preferred.
A review of additive manufacturing
. Int. Sch. Res. Notices 2012,The status, challenges, and future of additive manufacturing in engineering
. Comput. Aided Des. 69, 65–89 (2015). https://doi.org/10.1016/j.cad.2015.04.001Computed tomography for dimensional metrology
. CIRP Ann. - Manuf. Technol. 60, 821–842 (2011). https://doi.org/10.1016/j.cirp.2011.05.006Industrial applications of computed tomography
. CIRP Ann. - Manuf. Technol. 63, 655–677 (2014). https://doi.org/10.1016/j.cirp.2014.05.011Towards geometrical calibration of x-ray computed tomography-a review
. Meas. Sci. Technol. 26,X-ray computed tomography: from medical imaging to dimensional metrology
. Precis. Eng. 60, 544–569 (2019). https://doi.org/10.1016/j.precisioneng.2019.06.007Enhancement and proof of accuracy of industrial computed tomography (CT) measurements
. CIRP Ann. 56, 495–498 (2007). https://doi.org/10.1016/j.cirp.2007.05.118Sense and non-sense of beam hardening correction in CT metrology
. CIRP Ann. - Manuf. Technol. 61, 495–498 (2012). https://doi.org/10.1016/j.cirp.2012.03.013Improving the accuracy of CT dimensional metrology by a novel beam hardening correction method
. Meas. Sci. Technol. 26,Simulation-aided investigation of beam hardening induced errors in CT dimensional metrology
. Meas. Sci. Technol. 25,An experimental study on the influence of scatter and beam hardening in x-ray CT for dimensional metrology
. Meas. Sci. Technol. 27,Correction for beam hardening in computed tomography
. Phys. Med. Biol. 24, 81 (1979). https://doi.org/10.1088/0031-9155/24/1/008Beam hardening correction for middle-energy industrial computerized tomography
. IEEE Trans. Nucl. Sci. 53, 2796–2807 (2006). https://doi.org/10.1109/TNS.2006.879825A beam hardening correction method based on HL consistency
. Proc. SPIE 6318, 583–592 (2006). https://doi.org/10.1117/12.682869Beam hardening correction for fan-beam CT imaging with multiple materials
. IEEE NSS MIC, 3566–3570 (2010. https://doi.org/10.1109/NSSMIC.2010.5874473Data consistency condition–based beam-hardening correction
. Opt. Eng. 50, 076501 (2011). https://doi.org/10.1117/1.3599869Optimization based beam-hardening correction in CT under data integral invariant constraint
. Phys. Med. Biol. 63,Beam hardening correction for a cone-beam CT system and its effect on spatial resolution
. Chinese Phys. C 35, 978 (2011). https://doi.org/10.1088/1674-1137/35/10/018A fast beam hardening correction method incorporated in a filtered back-projection based MAP algorithm
. Phys. Med. Biol. 62, 1810 (2017). https://doi.org/10.1088/1361-6560/aa56b5Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography
. Med. Phys. 33, 1269–1274 (2006). https://doi.org/10.1118/1.2188076Simplified statistical image reconstruction for X-ray CT with beam-hardening artifact compensation
. IEEE Trans. Med. Imaging 39, 111–118 (2019). https://doi.org/10.1109/TMI.2019.2921929Alternating minimization algorithms for transmission tomography
. IEEE Trans. Med. Imaging 26, 283–297 (2007). https://doi.org/10.1109/TMI.2006.886806Energy-selective reconstructions in x-ray computerized tomography
. Phys. Med. Biol. 21, 733–744 (1976). https://doi.org/10.1088/0031-9155/21/5/002A framework for spectral artifact corrections in X-ray CT
. IEEE Trans. Biomed. Eng. 2, 128–141 (1981). https://doi.org/10.1109/TBME.1981.324786A method of iterative data refinement and its applications
. Math. Methods Appl. Sci. 7, 108–123 (1985). https://doi.org/10.1002/mma.1670070108An iterative approach to the beam hardening correction in cone beam CT
. Med. Phys. 27, 23–29 (2000). https://doi.org/10.1118/1.598853Iterative correction of beam hardening artifacts in CT
. Med. Phys. 38, S36–S49 (2011). https://doi.org/10.1118/1.3577758A novel beam hardening correction method requiring no prior knowledge, incorporated in an iterative reconstruction algorithm
. NDT & E Int. 51, 68–73 (2012). https://doi.org/10.1016/j.ndteint.2012.07.002Tsinghua Thomson scattering X-ray source
. Nucl. Instrum. Methods Phys. Res., Sect. A 608, S70–S74 (2009). https://doi.org/10.1016/j.nima.2009.05.088Development of a seven-cell S-band standing-wave RF-deflecting cavity for Tsinghua Thomson scattering X-ray source
. Nucl. Sci. Tech. 32, 36 (2021). https://doi.org/10.1007/s41365-021-00871-5Commissioning of laser electron gamma beamline SLEGS at SSRF
. Nucl. Sci. Tech. 33, 87 (2022). https://doi.org/10.1007/s41365-022-01076-0Progress of photonuclear cross sections for medical radioisotope production at the SLEGS energy domain
. Nucl. Sci. Tech. 34, 187 (2023). https://doi.org/10.1007/s41365-023-01339-4The SLEGS beamline of SSRF
. Nucl. Sci. Tech. 35, 111 (2024). https://doi.org/10.1007/s41365-024-01469-3Monochromatic computed tomography with a compact laser-driven X-ray source
. Sci. Rep. 3, 1313 (2013). https://doi.org/10.1038/srep01313Energy-angle correlation correction algorithm for monochromatic computed tomography based on Thomson scattering X-ray source
. J. Appl. Phys. 122,Experimental feasibility of dual-energy computed tomography based on the Thomson scattering X-ray source
. J. Synchrotron Radiat. 25, 1797–1802 (2018). https://doi.org/10.1107/S1600577518012663Spectroscopic imaging at compact inverse Compton X-ray sources
. Phys. Med. 79, 137–144 (2020). https://doi.org/10.1016/j.ejmp.2020.11.015Hard X-ray phase-contrast imaging with the Compact Light Source based on inverse Compton X-rays
. J. Synchrotron Radiat. 16, 43–47 (2009). https://doi.org/10.1107/S090904950803464XX-ray phase-contrast tomography with a compact laser-driven synchrotron source
. Proc. Natl. Acad. Sci. 112, 5567–5572 (2015). https://doi.org/10.1073/pnas.1500938112In-line phase-contrast imaging based on Tsinghua Thomson scattering x-ray source
. Rev. Sci. Instrum. 85,Recent progress of phase-contrast imaging at Tsinghua Thomson-scattering X-ray source
. Nucl. Instrum. Methods Phys. Res., Sect. B 402, 364–369 (2017). https://doi.org/10.1016/j.nimb.2017.02.062A simulation method of gamma-ray phase contrast imaging for metal samples
. Nucl. Instrum. Methods Phys. Res., Sect. A 1053,Linearly polarized X-ray fluorescence computed tomography based on a Thomson scattering light source: a Monte Carlo study
. J. Synchrotron Radiat. 27, 737–745 (2020). https://doi.org/10.1107/S1600577520003574Measurement of the spatial polarization distribution of circularly polarized gamma rays produced by inverse Compton scattering
. Phys. Rev. A 107,Demonstration of tomographic imaging of isotope distribution by nuclear resonance fluorescence
. AIP Adv. 9,Selective isotope CT imaging based on nuclear resonance fluorescence transmission method
. IEEE Trans. Nucl. Sci. 67, 1976–1984 (2020). https://doi.org/10.1109/TNS.2020.3004565Isotope-sensitive imaging of special nuclear materials using computer tomography based on scattering nuclear resonance fluorescence
. Phys. Rev. Appl. 16,Rapid interrogation of special nuclear materials by combining scattering and transmission nuclear resonance fluorescence spectroscopy
. Nucl. Sci. Tech. 32, 84 (2021). https://doi.org/10.1007/s41365-021-00914-xNondestructive determination of isotopic abundance using multi-energy nuclear resonance fluorescence driven by laser Compton scattering source
. J. Appl. Phys. 135,Thomson scattering of intense lasers from electron beams at arbitrary interaction angles
. Phys. Rev. E 52, 5425 (1995). https://doi.org/10.1103/PhysRevE.52.5425A reconstruction method for dual high-energy CT with MeV X-rays
. IEEE Trans. Nucl. Sci. 58, 537–546 (2011). https://doi.org/10.1109/TNS.2011.2112779GEANT4—a simulation toolkit
. Nucl. Instrum. Methods Phys. Res., Sect. A 506, 250 (2003). https://doi.org/10.1016/S0168-9002(03)01368-8A very compact inverse Compton scattering gamma-ray source
. High Power Laser and Particle Beams 34,Design, fabrication, and testing of low-group-velocity S-band traveling-wave accelerating structure
. Nucl. Sci. Tech. 33, 147 (2022). https://doi.org/10.1007/s41365-022-01124-9Design and test of an X-band constant gradient structure
. Phys. Rev. Accel. Beams 27,CAIN, Version 2.42
, https://www-jlc.kek.jp/tauchi/index/cain/non-linearQED/CainMan242.pdf (last accessedX-Ray Mass Attenuation Coefficients
, https://www.nist.gov/pml/x-ray-mass-attenuation-coefficients (last accessedDual color x rays from Thomson or Compton sources
. Phys. Rev. ST Accel. Beams 17,Two-colour X-gamma ray inverse Compton back-scattering source
. EPL 120,Dual-color γ-rays via all-optical Compton scattering from a cascaded laser-driven wakefield accelerator
. Plasma Phys. Control. Fusion 61,One-shot dual-energy subtraction chest imaging with computed radiography: clinical evaluation of film images
. Radiology 168, 67–72 (1988). https://doi.org/10.1148/radiology.168.1.3289096Single-exposure dual-energy computed radiography
. Med. Phys. 17, 866–875 (1990). https://doi.org/10.1118/1.596479The authors declare that they have no competing interests.