logo

Design of a mobile neutron radiography installation based on a compact sealed tube neutron generator

Design of a mobile neutron radiography installation based on a compact sealed tube neutron generator

Ma Wei-Chao
Dong Ai-Ping
Yao An-Ju
Li Zhong-Min
Li Wen-Jie
Yue Jin-Sheng
Nuclear Science and TechniquesVol.8, No.1pp.53-55Published in print 01 Feb 1997
40402

A series of optimum conditions are taken into account in the construction of neutron radiography (NR) installation based on a sealed tube neutron generator capable of gnerating 1010 n/s with 14 MeV. The characteristics of NNU screens, a kind of self-made 6LiF•ZnS(Ag) scintillation intensifying screen are presented. Finally, some neutron radiographies taken by this NR installation and NNU screens are given.

Neutron radiographyMobileNeutron tubeScintillation screen
References
1 Schmidt K A. Neutron radiography proceedings of the second world conference, EUR-11021. Prodrecht, Netherlands: Reidel, 1987; 239
2 Cluzeau S, Dubouchet M. Neutron radiography proceedings of the third world conference. Osaka, Japan, May 14~18, 1989; 14: 205
3 Hawkesworth M R. Mobile equipment for neutron radiography using a californium-252 source, HL 78/3938(c.14), Harwell: AERE, 1978
4 Profio A E. Radiation shielding and dosimetry. New York: John Wiley Z Sons, 1979
5 Ma Wei-Chao, Zhou Ming-Da. Atomic Energy Science and Technology (in Chinese), 1990; 24(2): 7
6 Zhou Ming-Da. Ma Wei-Chao, Niu Ji-Zhen et al. Nuclear Techniques (in Chinese), 1994; 17(7): 417
7 Ma Wei-Chao, Jin Zhong-Tie, Zhou Ming-Da et al. Science in China (in Chinese), 1991; A21: 394
8 Ma Wei-Chao, Jin Zhong-Tie, Zhou Ming-Da et al. Nuclear Techniques (in Chinese), 1991: 14(8): 459