1 Introduction
Isochronous mass spectrometry (IMS) of heavy-ion storage rings plays an important role in the mass measurements of short-lived nuclei [1, 2]. There are three storage ring facilities that conduct such experiments worldwide [3-6], namely, the experimental cooler-storage ring (CSRe) in Lanzhou, China; the experimental storage ring (ESR) in Darmstadt, Germany; and the Rare-RI Ring (R3) in Saitama, Japan. In IMS experiments, the nuclei of interest are produced in projectile fragmentation (PF) or in in-flight fission nuclear reactions, where the production cross sections are related to the binding energies of the fragments [7-9]. The reaction products of interest are selected with a fragment separator and injected into the storage ring for mass measurements. The revolution times of the stored nuclides are directly related to their mass-to-charge (m/q) ratios. The revolution times are typically measured by using dedicated timing detectors [10-13]. It is obvious that only those revolution times that could unambiguously be assigned to a specific ion species can be used [14, 15].
Particle identification (PID) is a prerequisite in experiments with radioactive ion beams (RIBs) produced in a nuclear reaction and is routinely accomplished along an RIB beam line by measuring the time of flight (TOF), energy loss (ΔE), and magnetic rigidity (Bρ) for each particle [16, 17]. In particular, the atomic number Z is mainly determined by using the ΔE value, which is usually measured with various ionization-type detectors placed along the beam line.
Among the storage-ring-based facilities, the R3 in RIKEN is the only one where a PID within a beam line can be performed [18, 19], where the quasi-DC beam from the superconducting cyclotron is employed. Thus, the RIBs can indeed be identified on an event-by-event basis prior to their injection into the R3. It is very different in the cases of the CSRe and ESR. The driver accelerator at the facility in Lanzhou is the heavy-ion synchrotron CSRm [20]. The primary beams are rapidly extracted from the CSRm within ∼300 ns. Correspondingly, the produced RIBs have a similar bunched structure. Therefore, event-by-event PID is not feasible in the RIBLL2 radioactive-ion beam line connecting the CSRm and the CSRe. A similar situation can be observed at the GSI Helmholtz Centre for Heavy Ion Research in Darmstadt, Germany, where the ions are fast-extracted from the heavy-ion synchrotron SIS-18, analyzed in-flight with the fragment separator FRS, and injected into the ESR for isochronous mass measurements [21]. In this work, we examined the sensitivity of the timing detectors to the charge of the stored ions for the purpose of performing in-ring PID.
Using IMS at the CSRe, we measured the masses of more than 30 short-lived nuclei [22-32]. For a recent review, the reader is referred to Refs. [5, 6, 27] and the references cited therein. In these experiments, the ions were identified almost solely through their m/q ratios by comparing the revolution time spectrum obtained experimentally with the simulated one [14, 15]. An m/q resolving power of 3 × 105 was achieved at the CSRe, which was sufficient to identify the isomeric states in 101In and 52Co [24, 28]. However, for some pairs of ions with very similar m/q ratios, such as 51Co27+ and 34Ar18+, the revolution times were too close to each other to be resolved clearly. Charge determination can provide crucial information for PID in these cases. Charge-resolved IMS was developed by analyzing the average amplitudes of the signals from the timing detector induced by the stored ions [33]. This method was used successfully to determine the mass of 51Co for the first time. Although the charge difference (ΔZ) of 51Co27+ and 34Ar18+ was relatively large, some events could not be unambiguously identified because of the limited charge resolution in a previous study [33].
A higher charge resolution is desired. For example, the masses of 54,56Ti nuclides were measured in an earlier experiment at the CSRe [23, 29]. The 55Ti nuclide must have been produced in significant amounts in this experiment according to the yields of the neighboring nuclei; however, it could not be separated from 50Ca. To measure the mass of 55Ti, we need to resolve 55Ti22+ and 50Ca20+ by charge, where ΔZ is only 2. Such high charge resolution was not realized in that experiment. Owing to the limited charge resolution, mass measurements of N=Z nuclides with conventional IMS at the CSRe or ESR are usually regarded as unfeasible. The N=Z nuclides with ΔZ=2 must be resolved by charge, whereas the neighboring N=Z (ΔZ=1) nuclides can be resolved by their revolution times because the difference in their m/q ratios is sufficiently large, owing to the odd-even staggering of the binding energies. If ions with ΔZ=2 can be resolved by charge, then, in principle, all nuclides can be identified and measured in IMS experiments.
In this paper, we describe a new method in which the detailed characteristics of the timing detector are considered in the data analysis. The charge resolution of the IMS was improved significantly, leading to a complete separation of 34Ar and 51Co. Possible future developments are discussed as well.
2 Experiment and the timing detector
The following discussions are based on the same experimental data that were analyzed in an earlier study [33]. More details about the experiment can be found in Refs. [33-35]. This experiment aimed to measure the masses of Tz=-3/2 nuclei in the pf shell. The nuclei of interest were produced using a projectile fragmentation of 463 MeV/u of 58Ni19+ primary beams in a 15-mm 9Be production target. At this energy, the fragments emerged from the target predominantly as bare ions. Therefore, in the following, we assume the atomic charge q to be equal to the atomic number Z. The RIBLL2 and CSRe were set to a fixed magnetic rigidity of Bρ = 5.677 Tm. All fragments within the Bρ acceptance of ∼±0.2% were injected into the CSRe.
The revolution times of the stored ions were measured by using a timing detector equipped with a carbon foil of 19 μg/cm2 in thickness and 40 mm in diameter [11]. The foil was positioned in the circulation path of the stored ions. When an ion passed through the carbon foil, secondary electrons were released from the foil surface and guided isochronously to a set of micro-channel plates (MCP) in the Chevron configuration [36]. The MCP had the same diameter as that of the carbon foil, and the micro-channels were 5 μm in diameter. When an electron hit a channel of the MCP, an avalanche of further secondary electrons propagated through the channel. A bunch of electrons exiting from the rear side of the channel was collected by a conical anode. A signal can be generated with the activation of one or more channels. The negative-voltage signal was directly transmitted from the anode to a digital oscilloscope for data acquisition. The recording time was 200 μs for each injection in this experiment.
The number of electrons from the carbon foil induced by an ion was roughly proportional to the energy loss, which scales with q2=Z2 [11]. Consequently, both the average signal amplitude (A0) and the detection efficiency (η) of an ion depended strongly on its atomic number Z.
Figure 1 (a) shows a two-dimensional plot of the revolution time T vs. A0 obtained in the experiment, and this plot is similar to that in Fig. 3 given in an earlier work [33]. The 51Co27+ and 34Ar18+ ions can be resolved using the A0 value, albeit not completely separated. Figure 1 (a) is an analogue of the typical PID plots at an in-flight separator [16, 17], although with a lower charge resolution but with a higher m/q resolution. Figure 1(b) shows a two-dimensional plot of the revolution time T vs. η. The two plots in Fig. 1 are quite similar. It seems that A0 provides a better charge resolution for heavier ions, whereas η provides a better charge resolution for lighter ones.
-202104/1001-8042-32-04-004/alternativeImage/1001-8042-32-04-004-F001.jpg)
3 Analysis of the signal amplitudes
In an earlier study, the average signal amplitude (A0) was used to resolve the 51Co27+ and 34Ar18+ ions [33]. Figure 1(a) shows a scatter plot of the revolution time T vs. A0 and the projected histogram for 34Ar and 51Co. Although the two ion species can be well resolved, there still exists an overlap between the two Gaussian-like distributions.
Assuming that each microchannel was fully discharged after the electron impact and thus provided the same contribution to the signal, we found that A0 was roughly proportional to the average number of activated microchannels and, in turn, to the number of secondary electrons released from the foil surface. However, there were ion passages through the detector, which did not generate signals. This reflects the finite detection efficiency η [33], which includes electron hits in between the channels (geometrical efficiency) and hits into the already discharged channels (dynamic efficiency). We define an average signal amplitude corrected by the total efficiency as A1:
Clearly, A1 is proportional to the total number of micro-channels activated by an ion. Figure 2(b) shows a scatter plot of the revolution time T vs. A1 and the projected histogram for 34Ar and 51Co. It can be seen clearly from the figure that the separation of these two ions became better.
-202104/1001-8042-32-04-004/alternativeImage/1001-8042-32-04-004-F002.jpg)
After a micro-channel was activated to output the avalanche electrons, it took 10 ms to recharge the channel. During this period, the channel did not respond to other coming electrons. Because the measurement time is much shorter than the recharging time, each micro-channel can be used at most once during the measurement [37]. If the number of stored ions is too large for one injection into the CSRe, the total number of activated microchannels would be large and the chance for each electron to activate a microchannel would be reduced, leading to reduced A0 and η values. This dynamic efficiency obviously depends on the number of stored ions and their charge. The sum amplitude of all signals (As) was a direct measure of the total number of activated channels in one injection. Thus, it is expected that the A1 values have a negative correlation with the As values for one ion species.
In the present experiment, the number of stored ions ranged from 2 to 46 in various injections, with the most probable value being 21. The As values ranged from 50 to 300 V. The relationship between the A1 and the As values was similar for all ion species, as shown in Fig. 3 for the example of the 36K and 53Ni ions, which can be clearly identified using their revolution times. The mean
-202104/1001-8042-32-04-004/alternativeImage/1001-8042-32-04-004-F003.jpg)
A new parameter A2 is defined as an estimate of the A1 value at As = 0 V. The A2 value is proportional to the number of channels that should be activated by the ion if all the micro-channels are available. Thus, it is directly related to the number of electrons released from the detector foil owing to this ion. Considering the constant slope for different ion species, as shown in Fig. 3, we can calculate the A2 value as
Here, the parameter B represents the slope shown in Fig. 2 and is determined by using all ion species with a proton number of Z>8 and more than 100 counts. It is equal to B=-9.05(7) × 10-4 V-1. Figure 2(c) shows a scatter plot of the revolution time T vs. A2 and the projected histogram for 34Ar and 51Co ions. It can be seen from the figure that the two ions are completely separated.
Because the revolution time T is Bρ dependent on the ions of 34Ar and 51Co [3, 4], the T values should depend on the average passage position of the ions through the detector. As shown in Fig. 2, the values of A0, A1, and A2 have no correlation with the revolution time T, proving the position independence of A0, A1, and A2 in this experiment.
Using A2 for the PID, we determined the mass excess of 51Co to be -27,332(41) keV, which is in agreement with the previously obtained value of -27,342(48) [33]. The smaller mass uncertainty in this analysis was mainly due to the larger statistics obtained under less strict constraints. In an earlier work [33], only the particles that were stored for more than 300 revolutions in the CSRe were used in the analysis. Using the improved data analysis methods, we lowered the threshold in the present work to 80 revolutions, thus increasing the statistics.
4 Charge resolution
The A0, A1, and A2 values were calculated for all ions. Figure 4(a) shows the average values of these three parameters for ions with the same proton number Z. As can be seen in the figure, the A1 and A2 values are very similar, whereas A0 is larger than the other two parameters for lighter ions. A2 increases rapidly with the proton number and approaches A0. It is evident that A2 is more sensitive to proton number Z. The standard deviations of these three parameters are shown in Fig. 4(b) as a function of Z. For heavy ions (Z∼20), they are similar for all three parameters, whereas for lighter ions, the standard deviation of A0 is considerably larger.
-202104/1001-8042-32-04-004/alternativeImage/1001-8042-32-04-004-F004.jpg)
The charge resolution ratio R was introduced to represent the separation of the two ion species. R is defined as
where A indicates the parameters used in the charge identification, Z is the proton number, and ΔZ is the proton number difference between the two ion species. For the normal distribution, two peaks can be resolved if R 2, corresponding to less than 2.5In the case of R=1, two peaks can be identified with 16% overlapping events.
Figure 5 shows the charge resolution ratios for different pairs of ions with ΔZ=2. The charge resolution ratios for A2 (R(A2)) were the largest for all ions, with an increase of 10The A2 parameter provided the highest charge resolution. With the use of the A2 values in the calculation, Figure 6 shows the R(A2) for pairs of ions with various ΔZ values as a function of Z.
-202104/1001-8042-32-04-004/alternativeImage/1001-8042-32-04-004-F005.jpg)
-202104/1001-8042-32-04-004/alternativeImage/1001-8042-32-04-004-F006.jpg)
The R values are directly related to ΔZ/Z. In this experiment, pairs of ions with ΔZ/Z>0.22 can be clearly resolved.
Only a moderate charge resolution was achieved in this experiment because the charge resolution was not particularly optimized. A better charge resolution can be realized with several technical improvements. The charge resolution can be improved by extending the recording time for each injection, i.e., from the present 200 μs to 400-600 μs. A lower number of stored ions in an individual injection will also lead to a higher resolution. Two timing detectors, a new IMS method that is under development and which will be applied in future experiments at the CSRe [12, 29, 39-41], could also increase the charge resolution. Finally, MCP plates with 2 μm of pore size will be adopted, thus boosting the number of microchannels.
5 Summary
In the IMS experiments, charge resolution provides crucial information for the particle identification of ion pairs with m/q ratios that are too similar to be resolved by their revolution times. In an earlier study, a charge-resolved IMS was developed at the CSRe to resolve the 51Co27+ and 34Ar18+ ions. However, the two ion types were not completely separated owing to the limited charge resolution. In this paper, a new analysis method is presented that explicitly considers the average signal amplitudes, detection efficiencies, and number of stored ions in the data analysis. The charge resolution of the IMS was significantly improved for ions with a proton number of Z<22, leading to a complete separation of 34Ar and 51Co. The mass excess of 51Co was determined to be -27,332(41) keV, which is in agreement with the value obtained in a previous work [33]. The developed analysis method may be of broader interest for storage ring-based atomic and nuclear physics experiments using similar types of detectors.
First isochronous mass spectrometry at the experimental storage ring ESR
. Nucl. Instr. and Meth. in Phys. Res. A, 446, 569 (2000). doi: 10.1016/S0168-9002(99)01192-4Isochronous mass measurements of hot exotic nuclei
. Hyperfine Interactions, 132, 291-297 (2001). doi: 10.1023/A:1011911720453Nuclear physics experiments with ion storage rings
. Nucl. Instr. and Meth. in Phys. Res. B, 317, 603-616 (2013). doi: 10.1016/j.nimb.2013.07.025Nuclear physics with unstable ions at storage rings
. Prog. Part. Nucl. Phys. 73, 84-140 (2013). doi: 10.1016/j.ppnp.2013.07.002Storage ring mass spectrometry for nuclear structure and astrophysics research
. Phys. Scr., 91, 073002 (2016). doi: 10.1088/0031-8949/91/7/073002Heavy-ion storage rings and their use in precision experiments with highly charged ions
. Prog. Part. Nucl. Phys. 115, 103811 (2020). doi: 10.1016/j.ppnp.2020.103811Odd-even staggering in yields of neutron-deficient nuclei produced by projectile fragmentation
. Phys. Rev. C, 94, 044615 (2016). doi: 10.1103/PhysRevC.94.044615Binding energies of near proton-drip line Z = 22-28 isotopes determined from measured isotopic cross section distributions
. Sci. China-Phys. Mech. Astron. 62, 012013 (2019). doi: 10.1007/s11433-018-9256-8Improved FRACS parameterizations for cross sections of isotopes near the proton drip line in projectile fragmentation reactions
, Nucl. Sci. Tech. 29, 96 (2018). doi: 10.1007/s41365-018-0439-4Mass measurements of exotic nuclei at the ESR
. Nucl. Instr. and Meth. in Phys. Res. B, 70, 455-458 (1992). doi: 10.1016/10.1016/0168-583X(92)95965-TA high performance Time-of-Flight detector applied to isochronous mass measurement at CSRe
. Nucl. Instr. and Meth. Phys. Res. A, 624, 109 (2010). doi: 10.1016/j.nima.2010.09.001Time-of-flight detectors with improved timing performance for isochronous mass measurements at the CSRe
, Nucl. Instr. and Meth. in Phys. Res. A, 756 (2014) 1. doi: 10.1016/j.nima.2014.04.051Present status of Rare-RI Ring facility at RIBF
, Phys. Scripta T166, 014039 (2015). doi: 10.1088/0031-8949/2015/T166/014039Precision isochronous mass measurements at the storage ring CSRe in Lanzhou
. Nucl. Instr. Meth. Phys. Res. A, 654, 213 (2011). doi: 10.1016/j.nima.2011.07.018Particle identification and revolution time corrections for the isochronous mass spectrometry in storage rings
, Nucl. Instr. Meth. Phys. Res. A, 941, 162331 (2019). doi: 10.1016/j.nima.2019.06.072Simultaneous measurement of β-delayed proton and γ emission of 26P for the 25Al(p,γ), 26Si reaction rate
. Physical Review C, 101, 024305 (2020). doi: 10.1103/PhysRevC.101.024305Towards the full realization of the RIBLL2 beam line at the HIRFL-CSR complex
. Science Bulletin, 63, 78 (2018). doi: 10.1016/j.scib.2017.12.005Construction of rare-RI ring at RIKEN RI Beam Factory
. Nucl. Instrum. Meth. in Phys. Res. 317, 629-635 (2013). doi: 10.1016/j.nimb.2013.06.004The challenge of precision mass measurements of short-lived exotic nuclei: Development of a new storage ring mass spectrometry
. Int. J. Mass Spectr. 349-350, 240-246 (2013). doi: 10.1016/j.ijms.2013.04.027The heavy ion cooler-storage-ring project (HIRFL-CSR) at Lanzhou
. Nucl. Instrum. Meth. Phys. Res. A, 488, 11-25 (2002). doi: 10.1016/S0168-9002(02)00475-8Mass and lifetime measurements of exotic nuclei in storage rings
. Mass Spectr. Rev. 27, 428-469 (2008). doi: 10.1002/mas.20173Mass measurements for the Tz=-2 fp-shell nuclei 40Ti, 44Cr, 46Mn, 48Fe, 50Co, and 52Ni
. Phys. Rev. C, 102, 054311 (2020). doi: 10.1103/PhysRevC.102.054311Masses of neutron-rich 52-54Sc and 54,56Ti nuclides: The N=32 subshell closure in scandium
. Phys. Rev. C, 99 064303 (2019). doi: 10.1103/PhysRevC.99.064303Masses of ground and isomeric states of 101In and configuration-dependent shell evolution in odd-A indium isotopes
. Phys. Rev. C, 100, 051303(R) (2019). doi: 10.1103/PhysRevC.100.051303Isochronous mass measurements of Tz=-1 fp-shell nuclei from projectile fragmentation of 58Ni
. Phys. Rev. C, 98, 014319 (2018). doi: 10.1103/PhysRevC.98.014319Masses of the Tz=-3/2 nuclei 27P and 29S
. Phys. Rev. C, 98, 014315 (2018). doi: 10.1103/PhysRevC.98.014315Precision mass measurements of short-lived nuclides at HIRFL-CSR in Lanzhou
. Front. Phys. 13(6), 132112 (2018). doi: 10.1007/s11467-018-0844-5Identification of the lowest T=2, Jπ=0+ isobaric analog state in 52Co and its impact on the understanding of β-decay properties of 52Ni
. Phys. Rev. Lett. 117, 182503 (2016). doi: 10.1103/PhysRevLett.117.182503Direct mass measurements of neutron-rich 86Kr projectile fragments and the persistence of neutron magic number N=32 in Sc isotopes
, Chin. Phys. C 39, 104001 (2015). doi: 10.1088/1674-1137/39/10/104001Direct mass measurements of short-lived A=2Z-1 nuclides 63Ge, 65As, 67Se, and 71Kr and their impact on nucleosynthesis in the rp process
. Phys. Rev. Lett. 106, 112501 (2011). doi: 10.1103/PhysRevLett.106.112501High-precision QEC values of superallowed 0+→0+ β-emitters 46Cr, 50Fe and 54Ni
. Phys. Lett. B, 767, 20-24 (2017). doi: 10.1016/j.physletb.2017.01.039Mass measurements of neutron-deficient Y, Zr, and Nb isotopes and their impact on rp and νp nucleosynthesis processes
. Phys. Lett. B, 781 358-363 (2018). doi: 10.1016/j.physletb.2018.04.009Charge and frequency resolved isochronous mass spectrometry and the mass of 51Co
. Physics Letters B, 735, 327 (2014). doi: 10.1016/j.physletb.2014.06.046Mass measurements of the neutron-deficient 41Ti, 45Cr, 49Fe, and 53Ni nuclides: First test of the isobaric multiplet mass equation in fp-shell nuclei
. Phys. Rev. Lett. 109, 102501 (2012). doi: 10.1103/PhysRevLett.109.102501Mass measurement of 45Cr and its impact on the Ca-Sc cycle in X-ray bursts
. Astrophys. J. Lett. 766, L8 (2013). doi: 10.1088/2041-8205/766/1/L8A timing detector with pulsed high-voltage power supply for mass measurements at CSRe
. Nucl. Instrum. Meth. Phys. Res. A, 755, 38 (2014). doi: 10.1016/j.nima.2014.04.031A data analysis method for isochronous mass spectrometry using two time-of-flight detectors at CSRe
. Chin. Phys. C 39, 106201 (2015). doi: 10.1088/1674-1137/39/10/106201First isochronous mass measurements with two time-of-flight detectors at CSRe
. Phys. Scr. T166, 014010 (2015). doi: 10.1088/0031-8949/2015/T166/014010An improvement of isochronous mass spectrometry: Velocity measurements using two time-of-flight detectors
. Nucl. Instrum Meth. Phys. Res. B, 376, 311-315 (2016). doi: 10.1016/j.nimb.2016.02.006Characterization of a double Time-Of-Flight detector system for accurate velocity measurement in a storage ring using laser beams
. Nucl. Instrum. Meth. Phys. Res. A, 931, 52 (2019). doi: 10.1016/j.nima.2019.03.058